Literature DB >> 20584433

Accuracy of Voxel-Based and Algebraic Formula-Based Methods in Quantifying Cerebral Aneurysm Volume by 3D-Rotational Digital Subtraction Angiography. An In-Vitro and In-Vivo Study.

N F Fanning1, H M O'Dwyer, J A B Bowden, P R Brennan, J Thornton.   

Abstract

SUMMARY: Accurate knowledge of cerebral aneurysm volume would be valuable in guiding the volume of embolized material required for optimal filling of an aneurysm sac and recording percentage volume filling. Algebraic volumes are frequently estimated by algebraic volume formulae. 3D digital subtraction angiography (DSA) aids endovascular treatment planning and yields volumetric data. Our aim was to define the accuracy of 3D-DSA in quantifying aneurysm volume using an automated voxel-based volumetric method (voxel volume method) and compare results to volumes calculated by ellipsoid and cylindrical algebraic formulae (algebraic volume method). We constructed 13 latex aneurysm moulds and measured their true volumes using a micropipette in-vitro. 3D-DSA was performed on contrast filled moulds and experimental volume estimated by both voxel and algebraic methods. In our in-vivo study we quantified the voxel and algebraic volumes from the 3D data sets of 75 cerebral aneurysms. The linear regression test provided correction values between voxel and algebraic methods. The in-vitro study showed that the voxel volume method was the most accurate (mean percentage deviation from true volume 3.7 +/- 3.5%; p=0.9). The ellipsoid method significantly underestimated - 11.2 +/- 13.6%; p < 0.05) and the cylindrical method overestimated (42.6 +/- 35.7%; p < 0.05) true aneurysm volume. Similar results were obtained in-vivo. While algebraic measurements could be corrected by an equation, the clinical usefulness of this equation is questionable due to the large volume range to achieve a 95% confidence interval. The voxel volume method is accurate in quantifying aneurysm volume. Aneurysms in-vivo do not conform to simple algebraic geometry. Aneurysm volume on 3D-DSA should be calculated by the voxel-based method and not by algebraic formulae.

Entities:  

Year:  2005        PMID: 20584433      PMCID: PMC3400046          DOI: 10.1177/159101990501100105

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  11 in total

1.  Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures.

Authors:  K Wiesent; K Barth; N Navab; P Durlak; T Brunner; O Schuetz; W Seissler
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

2.  Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results.

Authors:  R Fahrig; A J Fox; S Lownie; D W Holdsworth
Journal:  AJNR Am J Neuroradiol       Date:  1997-09       Impact factor: 3.825

3.  Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment.

Authors:  R Anxionnat; S Bracard; X Ducrocq; Y Trousset; L Launay; E Kerrien; M Braun; R Vaillant; F Scomazzoni; A Lebedinsky; L Picard
Journal:  Radiology       Date:  2001-03       Impact factor: 11.105

4.  Bioabsorbable polymeric material coils for embolization of intracranial aneurysms: a preliminary experimental study.

Authors:  Y Murayama; F Viñuela; S Tateshima; J K Song; N R Gonzalez; M P Wallace
Journal:  J Neurosurg       Date:  2001-03       Impact factor: 5.115

5.  Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms.

Authors:  Shinichi Tamatani; Yasushi Ito; Hiroshi Abe; Tetsuo Koike; Shigekazu Takeuchi; Ryuichi Tanaka
Journal:  AJNR Am J Neuroradiol       Date:  2002-05       Impact factor: 3.825

6.  Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction.

Authors:  A Rougée; C Picard; C Ponchut; Y Trousset
Journal:  Comput Med Imaging Graph       Date:  1993 Jul-Oct       Impact factor: 4.790

7.  Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: correlation between coil packing density and coil compaction.

Authors:  Y Kawanabe; A Sadato; W Taki; N Hashimoto
Journal:  Acta Neurochir (Wien)       Date:  2001       Impact factor: 2.216

8.  New expandable hydrogel-platinum coil hybrid device for aneurysm embolization.

Authors:  David F Kallmes; Naomi H Fujiwara
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

9.  Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm.

Authors:  Toshi Abe; Masaru Hirohata; Norimitsu Tanaka; Yusuke Uchiyama; Kazuyuki Kojima; Kiminori Fujimoto; Alexander M Norbash; Naofumi Hayabuchi
Journal:  AJNR Am J Neuroradiol       Date:  2002-04       Impact factor: 3.825

10.  CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study.

Authors:  M Piotin; P Gailloud; L Bidaut; S Mandai; M Muster; J Moret; D A Rüfenacht
Journal:  Neuroradiology       Date:  2003-04-26       Impact factor: 2.804

View more
  1 in total

1.  HydroCoil as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms.

Authors:  Noel F Fanning; Zsolt Berentei; Paul R Brennan; John Thornton
Journal:  Neuroradiology       Date:  2006-11-22       Impact factor: 2.804

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.