Scatter/primary in mammography: Monte Carlo validation.

J M Boone1, V N Cooper.   

Abstract

The purpose of this investigation was to compare and validate the performance of the SIERRA Monte Carlo simulation routines for the analysis of the scatter to primary ratio (SPR) in the mammography setting. Two Monte Carlo simulation methods were addressed, the direct method was a straightforward and geometrically accurate simulation procedure, and the convolution method uses idealized geometry (monoenergetic, normally incident delta function input to the scattering medium) to produce scatter point spread functions (PSFs). The PSFs were weighted by the x-ray spectrum of interest and convolved with the field of view to estimate SPR values. The SPR results of both Monte Carlo procedures were extensively compared to five published sources, including Monte-Carlo-derived and physically measured SPR assessments. The direct method demonstrated an overall agreement with the literature of 3.7% accuracy (N=5), and the convolution method demonstrated an average of 7.1% accuracy (N=14). The comparisons were made over a range of parameters which included field of view, phantom thickness, x-ray energy, and phantom composition. Limitations of the beam stop method were also discussed. The results suggest that the SIERRA Monte Carlo routines produce accurate SPR calculations and may be useful for a more comprehensive study of scatter in mammography.

Mesh:

Year:  2000        PMID: 10984229     DOI: 10.1118/1.1287052

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Scatter radiation in digital tomosynthesis of the breast.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

2.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

3.  Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose.

Authors:  Chao-Jen Lai; Chris C Shaw; Lingyun Chen; Mustafa C Altunbas; Xinming Liu; Tao Han; Tianpeng Wang; Wei T Yang; Gary J Whitman; Shu-Ju Tu
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

4.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

5.  On image quality metrics and the usefulness of grids in digital mammography.

Authors:  Han Chen; Mats Danielsson; Cheng Xu; Björn Cederström
Journal:  J Med Imaging (Bellingham)       Date:  2015-02-17

6.  The effect of skin thickness determined using breast CT on mammographic dosimetry.

Authors:  Shih-Ying Huang; John M Boone; Kai Yang; Alexander L C Kwan; Nathan J Packard
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

7.  Evaluation of scatter effects on image quality for breast tomosynthesis.

Authors:  Gang Wu; James G Mainprize; John M Boone; Martin J Yaffe
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

8.  Characterization of scatter magnitude and distribution in dedicated breast computed tomography with bowtie filters.

Authors:  Kimberly Kontson; Robert J Jennings
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-18

9.  Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

10.  The compressed breast during mammography and breast tomosynthesis: in vivo shape characterization and modeling.

Authors:  Alejandro Rodríguez-Ruiz; Greeshma A Agasthya; Ioannis Sechopoulos
Journal:  Phys Med Biol       Date:  2017-08-07       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.