Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design.

S D Cook1, S L Salkeld, T S Whitecloud, J Barbera.   

Abstract

The advantages of pedicle screw fixation depend on their ability to retain bony purchase until the fusion mass is stable. Osteoporotic bone and removal and replacement of pedicle screws in revision procedures substantially reduce screw mechanical fixation strength and can lead to clinical failure. The objective of this study was to determine if an expansive pedicle screw design could be used to improve biomechanical fixation in bone of compromised quality. Axial mechanical pullout testing was performed on paired expansive and conventional pedicle screws placed in fresh, unembalmed cadaveric vertebrae. Bone mineral density measurements (made using a dual-energy X-ray absorption meter) were used to characterize bone quality. A preliminary clinical and radiographic evaluation of 14 patients was also performed at a minimum 2-year follow-up. The mean axial pullout force in bone of all qualities was increased 30% when the expansive pedicle screw design was used. This included an appropriate 50% increase in pullout force in bone of poor quality (low bone mineral density). The preliminary clinical and radiographic results were supportive of the biomechanical design rationale and mechanical testing. The results were similar to those expected for spinal instrumentation using pedicle screws, even though compromised bone was present in two thirds of the cases in which the expansive screw was used.

Entities:  

Mesh:

Year:  2000        PMID: 10872761     DOI: 10.1097/00002517-200006000-00006

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  22 in total

1.  Cortical and Standard Trajectory Pedicle Screw Fixation Techniques in Stabilizing Multisegment Lumbar Spine with Low Grade Spondylolisthesis.

Authors:  Wayne K Cheng; Serkan İnceoğlu
Journal:  Int J Spine Surg       Date:  2015-08-31

2.  Biomechanical evaluation of an expansive pedicle screw in calf vertebrae.

Authors:  Wei Lei; Zixiang Wu
Journal:  Eur Spine J       Date:  2005-04-30       Impact factor: 3.134

3.  Biomechanical analysis of differing pedicle screw insertion angles.

Authors:  William Sterba; Do-Gyoon Kim; David P Fyhrie; Yener N Yeni; Rahul Vaidya
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-01-08       Impact factor: 2.063

Review 4.  [Stabilization of the osteoporotic spine from a biomechanical viewpoint].

Authors:  C-E Heyde; A Rohlmann; U Weber; R Kayser
Journal:  Orthopade       Date:  2010-04       Impact factor: 1.087

5.  Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface.

Authors:  Patrícia Silva; Rodrigo César Rosa; Antonio Carlos Shimano; Helton L A Defino
Journal:  Eur Spine J       Date:  2013-05-08       Impact factor: 3.134

6.  Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep.

Authors:  Shiyong Wan; Wei Lei; Zixiang Wu; Da Liu; Mingxuan Gao; Suochao Fu
Journal:  Eur Spine J       Date:  2010-06-25       Impact factor: 3.134

7.  The fates of pedicle screws and functional outcomes in a geriatric population following polymethylmethacrylate augmentation fixation for the osteoporotic thoracolumbar and lumbar burst fractures with mean ninety five month follow-up.

Authors:  Hsi-Hsien Lin; Ming-Chau Chang; Shih-Tien Wang; Chien-Lin Liu; Po-Hsin Chou
Journal:  Int Orthop       Date:  2018-02-11       Impact factor: 3.075

8.  Failure of cement-augmented pedicle screws in the osteoporotic spine: a case report.

Authors:  Addisu Mesfin; Christopher B Komanski; A Jay Khanna
Journal:  Geriatr Orthop Surg Rehabil       Date:  2013-09

9.  Effect of screw position on load transfer in lumbar pedicle screws: a non-idealized finite element analysis.

Authors:  Anna G U S Newcomb; Seungwon Baek; Brian P Kelly; Neil R Crawford
Journal:  Comput Methods Biomech Biomed Engin       Date:  2016-07-25       Impact factor: 1.763

10.  Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients.

Authors:  Fras Dakhil-Jerew; H Jadeja; A Cohen; J A N Shepperd
Journal:  Eur Spine J       Date:  2009-06-16       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.