Literature DB >> 10796934

Endovascular treatment of experimental canine aneurysms: feasibility with MR imaging guidance.

C M Strother1, O Unal, R Frayne, A Turk, R Omary, F R Korosec, C A Mistretta.   

Abstract

PURPOSE: To evaluate the feasibility of using magnetic resonance (MR) imaging to guide and monitor endovascular therapeutic procedures.
MATERIALS AND METHODS: Endovascular therapeutic procedures were performed with MR imaging guidance in eight dogs by using a 1.5-T MR unit with echo-planar imaging capabilities. Carotid arterial aneurysms were surgically created in four dogs. The ability to depict, track, and position catheters, guide wires, and Guglielmi detachable coils was assessed. Catheters were first positioned with fluoroscopic guidance. Tracking and depiction were achieved with MR imaging by using commercially available catheters filled with a gadopentetate dimeglumine solution and a fast, two-dimensional, time-resolved, variable-rate k-space sampling technique.
RESULTS: When either a catheter or the coaxial space between a catheter and a guide wire was filled with a solution of gadopentetate dimeglumine, catheter movement was always depicted. In the animals with aneurysms, it was possible to depict movement of a catheter into and out of the aneurysm. This was achieved by superimposing reconstructed images obtained during catheter movement onto a previously acquired MR angiogram ("road map"). Prototype Guglielmi detachable coils were successfully positioned and detached. Aneurysm obliteration was monitored with the acquisition of new road map images.
CONCLUSION: The results demonstrate the feasibility of using MR imaging to guide endovascular therapeutic procedures.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10796934     DOI: 10.1148/radiology.215.2.r00ma34516

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  10 in total

1.  Real-time magnetic resonance imaging to guide pediatric endovascular procedures.

Authors:  A N Raval; R J Lederman
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

2.  Low-dose intra-arterial contrast-enhanced MR aortography in patients based on a theoretically derived injection protocol.

Authors:  S Potthast; A-C Schulte; G M Bongartz; R Hügli; M Aschwanden; D Bilecen
Journal:  Eur Radiol       Date:  2005-06-21       Impact factor: 5.315

3.  Microcatheter tip enhancement in fluoroscopy: a comparison of techniques.

Authors:  Akihiro Takemura; Kenneth R Hoffmann; Masayuki Suzuki; Zhou Wang; Hussain S Rangwala; Hajime Harauchi; Stephen Rudin; Tokuo Umeda
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

4.  An algorithm for tracking microcatheters in fluoroscopy.

Authors:  Akihiro Takemura; Kenneth R Hoffmann; Masayuki Suzuki; Zhou Wang; Hussain S Rangwala; Hajime Harauchi; Stephen Rudin; Tokuo Umeda
Journal:  J Digit Imaging       Date:  2008-03       Impact factor: 4.056

5.  Real-time MRI guided atrial septal puncture and balloon septostomy in swine.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Ranil Desilva; Ronnier J Aviles; Victor J Wright; William H Schenke; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Catheter Cardiovasc Interv       Date:  2006-04       Impact factor: 2.692

6.  MR imaging of hydrogel filament embolic devices loaded with superparamagnetic iron oxide or gadolinium.

Authors:  Monika Killer; Edward M Keeley; Gregory M Cruise; Anne Schmitt; Mark R McCoy
Journal:  Neuroradiology       Date:  2010-07-13       Impact factor: 2.804

7.  Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in Swine.

Authors:  Amish N Raval; James D Telep; Michael A Guttman; Cengizhan Ozturk; Michael Jones; Richard B Thompson; Victor J Wright; William H Schenke; Ranil DeSilva; Ronnier J Aviles; Venkatesh K Raman; Michael C Slack; Robert J Lederman
Journal:  Circulation       Date:  2005-07-25       Impact factor: 29.690

8.  Preparation of Gd3+-containing polymer complex as a novel magnetic resonance signal-enhancing coating material.

Authors:  Jian Guo; Xiqun Jiang; Yong Hu; Changzheng Yang
Journal:  J Mater Sci Mater Med       Date:  2003-03       Impact factor: 3.896

9.  Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms.

Authors:  Zbigniew Serafin; Piotr Strześniewski; Władysław Lasek; Wojciech Beuth
Journal:  Med Sci Monit       Date:  2012-07

Review 10.  MR fluoroscopy in vascular and cardiac interventions (review).

Authors:  Maythem Saeed; Steve W Hetts; Joey English; Mark Wilson
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-26       Impact factor: 2.357

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.