An algorithm for tracking microcatheters in fluoroscopy.

Akihiro Takemura1, Kenneth R Hoffmann, Masayuki Suzuki, Zhou Wang, Hussain S Rangwala, Hajime Harauchi, Stephen Rudin, Tokuo Umeda.   

Abstract

Currently, a large number of endovascular interventions are performed for treatment of intracranial aneurysms. For these treatments, correct positioning of microcatheter tips, microguide wire tips, or coils is essential. Techniques to detect such devices may facilitate endovascular interventions. In this paper, we describe an algorithm for tracking of microcatheter tips during fluoroscopically guided neuroendovascular interventions. A sequence of fluoroscopic images (1,024 x 1,024 x 12 bits) was acquired using a C-arm angiography system as a microcatheter was passed through a carotid phantom which was on top of a head phantom. The carotid phantom was a silicone cylinder containing a simulated vessel with the shape and curvatures of the internal carotid artery. The head phantom consisted of a human skull and tissue-equivalent material. To detect the microcatheter in a given fluoroscopic frame, a background image consisting of an average of the four previous frames is subtracted from the current frame, the resulting image is filtered using a matched filter, and the position of maximum intensity in the filtered image is taken as the catheter tip position in the current frame. The distance between the tracked position and the correct position (error distance) was measured in each of the fluoroscopic images. The mean and standard deviation of the error distance values were 0.277 mm (1.59 pixels) and 0.26 mm (1.5 pixels), respectively. The error distance was less than 3 pixels in the 93.0% frames. Although the algorithm intermittently failed to correctly detect the catheter, the algorithm recovered the catheter in subsequent frames.

Entities:  

Mesh:

Year:  2008        PMID: 17318702      PMCID: PMC3043820          DOI: 10.1007/s10278-007-9016-9

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  18 in total

1.  Registration of three-dimensional cardiac catheter models to single-plane fluoroscopic images.

Authors:  S A Meyer; P D Wolf
Journal:  IEEE Trans Biomed Eng       Date:  1999-12       Impact factor: 4.538

2.  Real-time MR fluoroscopy for MR-guided iliac artery stent placement.

Authors:  A Buecker; J M Neuerburg; G B Adam; A Glowinski; T Schaeffter; V Rasche; J J van Vaals; A Molgaard-Nielsen; R W Guenther
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

3.  Guide-wire tracking during endovascular interventions.

Authors:  Shirley A M Baert; Max A Viergever; Wiro J Niessen
Journal:  IEEE Trans Med Imaging       Date:  2003-08       Impact factor: 10.048

4.  Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature.

Authors:  Shirley A M Baert; Everine B van de Kraats; Theo van Walsum; Max A Viergever; Wiro J Niessen
Journal:  IEEE Trans Med Imaging       Date:  2003-10       Impact factor: 10.048

5.  Interventional MR angiography with a floating table.

Authors:  Harald H Quick; Hilmar Kuehl; Gernot Kaiser; Stephanie Aker; Silke Bosk; Jörg F Debatin; Mark E Ladd
Journal:  Radiology       Date:  2003-09-18       Impact factor: 11.105

6.  An algorithm for mapping the catheter tip position on a fluorograph to the three-dimensional position in magnetic resonance angiography volume data.

Authors:  A Takemura; H Harauchi; M Suzuki; K R Hoffmann; K Inamura; T Umeda
Journal:  Phys Med Biol       Date:  2003-08-21       Impact factor: 3.609

7.  Pulsed fluoroscopy detectability from interspersed adaptive forced-choice measurements.

Authors:  P Xue; D L Wilson
Journal:  Med Phys       Date:  1996-11       Impact factor: 4.071

8.  Cath-Finder Catheter Tracking System: a new device for positioning of central venous catheters. Early experience from implantation of brachial portal systems.

Authors:  H Starkhammar; M Bengtsson; D A Kay
Journal:  Acta Anaesthesiol Scand       Date:  1990-05       Impact factor: 2.105

9.  A new peripherally implanted subcutaneous permanent central venous access device for patients requiring chemotherapy.

Authors:  R R Salem; B A Ward; T S Ravikumar
Journal:  J Clin Oncol       Date:  1993-11       Impact factor: 44.544

10.  Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment.

Authors:  Titus Kuehne; Maythem Saeed; Charles B Higgins; Kelly Gleason; Gabriele A Krombach; Oliver M Weber; Alastair J Martin; Daniel Turner; David Teitel; Phillip Moore
Journal:  Radiology       Date:  2003-02       Impact factor: 11.105

View more
  1 in total

1.  Aortic valve prosthesis tracking for transapical aortic valve implantation.

Authors:  M E Karar; D R Merk; C Chalopin; T Walther; V Falk; O Burgert
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-09-16       Impact factor: 2.924

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.