Literature DB >> 16946988

Microcatheter tip enhancement in fluoroscopy: a comparison of techniques.

Akihiro Takemura1, Kenneth R Hoffmann, Masayuki Suzuki, Zhou Wang, Hussain S Rangwala, Hajime Harauchi, Stephen Rudin, Tokuo Umeda.   

Abstract

We compared three techniques for enhancement of microcatheter tips in fluoroscopic images: conventional subtraction technique (CST); averaged image subtraction technique (AIST), which we have developed; and double average filtering (DAF) technique, which uses nonlinear background estimates. A pulsed fluoroscopic image sequence was obtained as a microcatheter was passed through a carotid phantom that was on top of a head phantom. The carotid phantom was a silicone cylinder containing a simulated vessel with the shape and curvatures of the internal carotid artery. The three techniques were applied to the images of the sequence, then the catheter tip was manually identified in each image, and 100 x 100 pixel images, centered at the indicated microcatheter tip positions, were extracted for the evaluations. The signal-to-noise ratio (SNR) was calculated in each of the extracted images from which the mean value of the SNR and its standard deviation (SD) were calculated for each technique. The mean values and the standard deviations were 4.36 (SD 3.40) for CST, 6.34 (SD 3.62) for AIST, and 3.55 (SD 1.27) for DAF. AIST had a higher SNR compared to CST in almost all frames. Although DAF yielded the smallest mean SNR value, it yielded the best SNR in those frames in which the microcatheter tip did not move between frames. We conclude that AIST provides the best SNR for a moving microcatheter tip and that DAF is optimal for a temporarily stationary microcatheter tip.

Entities:  

Mesh:

Year:  2007        PMID: 16946988      PMCID: PMC3043922          DOI: 10.1007/s10278-006-0855-6

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  16 in total

1.  Vascular stents as RF antennas for intravascular MR guidance and imaging.

Authors:  H H Quick; M E Ladd; D Nanz; K P Mikolajczyk; J F Debatin
Journal:  Magn Reson Med       Date:  1999-10       Impact factor: 4.668

2.  Accuracy of the LocaLisa system in catheter ablation procedures.

Authors:  F H Wittkampf; E F Wever; R Derksen; H Ramanna; R N Hauer; E O Robles de Medina
Journal:  J Electrocardiol       Date:  1999       Impact factor: 1.438

3.  Registration of three-dimensional cardiac catheter models to single-plane fluoroscopic images.

Authors:  S A Meyer; P D Wolf
Journal:  IEEE Trans Biomed Eng       Date:  1999-12       Impact factor: 4.538

4.  Endovascular procedures under near-real-time magnetic resonance imaging guidance: an experimental feasibility study.

Authors:  Y M Dion; H Ben El Kadi; C Boudoux; J Gourdon; N Chakfé; A Traoré; C Moisan
Journal:  J Vasc Surg       Date:  2000-11       Impact factor: 4.268

5.  Real-time MR fluoroscopy for MR-guided iliac artery stent placement.

Authors:  A Buecker; J M Neuerburg; G B Adam; A Glowinski; T Schaeffter; V Rasche; J J van Vaals; A Molgaard-Nielsen; R W Guenther
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

6.  Guide-wire tracking during endovascular interventions.

Authors:  Shirley A M Baert; Max A Viergever; Wiro J Niessen
Journal:  IEEE Trans Med Imaging       Date:  2003-08       Impact factor: 10.048

7.  Identifying and tracking a guide wire in the coronary arteries during angioplasty from X-ray images.

Authors:  D Palti-Wasserman; A M Brukstein; R P Beyar
Journal:  IEEE Trans Biomed Eng       Date:  1997-02       Impact factor: 4.538

8.  Determination of three-dimensional positions of known sparse objects from a single projection.

Authors:  K R Hoffmann; J Esthappan
Journal:  Med Phys       Date:  1997-04       Impact factor: 4.071

9.  Endovascular treatment of experimental canine aneurysms: feasibility with MR imaging guidance.

Authors:  C M Strother; O Unal; R Frayne; A Turk; R Omary; F R Korosec; C A Mistretta
Journal:  Radiology       Date:  2000-05       Impact factor: 11.105

10.  Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment.

Authors:  Titus Kuehne; Maythem Saeed; Charles B Higgins; Kelly Gleason; Gabriele A Krombach; Oliver M Weber; Alastair J Martin; Daniel Turner; David Teitel; Phillip Moore
Journal:  Radiology       Date:  2003-02       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.