BACKGROUND: Real-time MR imaging (rtMRI) is now technically capable of guiding catheter-based cardiovascular interventions. Compared with x-ray, rtMRI offers superior tissue imaging in any orientation without ionizing radiation. Translation to clinical trials has awaited the availability of clinical-grade catheter devices that are both MRI visible and safe. We report a preclinical safety and feasibility study of rtMRI-guided stenting in a porcine model of aortic coarctation using only commercially available catheter devices. METHOD AND RESULTS: Coarctation stenting was performed wholly under rtMRI guidance in 13 swine. rtMRI permitted procedure planning, device tracking, and accurate stent deployment. "Active" guidewires, incorporating MRI antennas, improved device visualization compared with unmodified "passive" nitinol guidewires and shortened procedure time (26+/-11 versus 106+/-42 minutes; P=0.008). Follow-up catheterization and necropsy showed accurate stent deployment, durable gradient reduction, and appropriate neointimal formation. MRI immediately identified aortic rupture when oversized devices were tested. CONCLUSIONS: This experience demonstrates preclinical safety and feasibility of rtMRI-guided aortic coarctation stenting using commercially available catheter devices. Patients may benefit from rtMRI in the future because of combined device and tissue imaging, freedom from ionizing radiation, and the ability to identify serious complications promptly.
BACKGROUND: Real-time MR imaging (rtMRI) is now technically capable of guiding catheter-based cardiovascular interventions. Compared with x-ray, rtMRI offers superior tissue imaging in any orientation without ionizing radiation. Translation to clinical trials has awaited the availability of clinical-grade catheter devices that are both MRI visible and safe. We report a preclinical safety and feasibility study of rtMRI-guided stenting in a porcine model of aortic coarctation using only commercially available catheter devices. METHOD AND RESULTS:Coarctation stenting was performed wholly under rtMRI guidance in 13 swine. rtMRI permitted procedure planning, device tracking, and accurate stent deployment. "Active" guidewires, incorporating MRI antennas, improved device visualization compared with unmodified "passive" nitinol guidewires and shortened procedure time (26+/-11 versus 106+/-42 minutes; P=0.008). Follow-up catheterization and necropsy showed accurate stent deployment, durable gradient reduction, and appropriate neointimal formation. MRI immediately identified aortic rupture when oversized devices were tested. CONCLUSIONS: This experience demonstrates preclinical safety and feasibility of rtMRI-guided aortic coarctation stenting using commercially available catheter devices. Patients may benefit from rtMRI in the future because of combined device and tissue imaging, freedom from ionizing radiation, and the ability to identify serious complications promptly.
Authors: A Bücker; J M Neuerburg; G B Adam; A Glowinski; T Schaeffter; V Rasche; J J van Vaals; R W Günther Journal: J Vasc Interv Radiol Date: 2001-06 Impact factor: 3.464
Authors: Arno Buecker; Elmar Spuentrup; Ralph Grabitz; Franz Freudenthal; Eberhard G Muehler; Tobias Schaeffter; Joop J van Vaals; Rolf W Günther Journal: Circulation Date: 2002-07-23 Impact factor: 29.690
Authors: Michael A Guttman; Cenghizhan Ozturk; Amish N Raval; Venkatesh K Raman; Alexander J Dick; Ranil DeSilva; Parag Karmarkar; Robert J Lederman; Elliot R McVeigh Journal: J Magn Reson Imaging Date: 2007-12 Impact factor: 4.813
Authors: Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Ranil Desilva; Ronnier J Aviles; Victor J Wright; William H Schenke; Ergin Atalar; Elliot R McVeigh; Robert J Lederman Journal: Catheter Cardiovasc Interv Date: 2006-04 Impact factor: 2.692
Authors: Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Smita Sampath; Ranil DeSilva; Ronnier J Aviles; Minnan Xu; Victor J Wright; William H Schenke; Ozgur Kocaturk; Alexander J Dick; Venkatesh K Raman; Ergin Atalar; Elliot R McVeigh; Robert J Lederman Journal: Circulation Date: 2006-02-20 Impact factor: 29.690
Authors: Philipp Kahlert; Holger Eggebrecht; Björn Plicht; Oliver Kraff; Ian McDougall; Brad Decker; Raimund Erbel; Mark E Ladd; Harald H Quick Journal: J Cardiovasc Magn Reson Date: 2010-10-13 Impact factor: 5.364