Literature DB >> 15968517

Low-dose intra-arterial contrast-enhanced MR aortography in patients based on a theoretically derived injection protocol.

S Potthast1, A-C Schulte, G M Bongartz, R Hügli, M Aschwanden, D Bilecen.   

Abstract

Multiple intra-arterial contrast agent injections are necessary during MR-guided endovascular interventions. In respect to the approved limits of maximum daily gadolinium dose, a low-dose injection protocol is mandatory. The objective of this study was to derive and apply a low-dose injection protocol for intra-arterial 3D contrast-enhanced MR aortography in patients. Injection rate (Qinj), concentration of injected gadolinium [Gd]inj and aortal blood flow rate (Qblood) were included for the theoretical evaluation of signal intensity (SI) of the arterial lumen. SI simulations were carried out at Qinj=2 versus 4 ml/s in the [Gd]inj range between 0-500 mM. Qinj and [Gd]inj with SI above the 75% threshold of the maximal SI were regarded as optimal injection parameters. [Gd]inj=50 mM and Qinj=4 ml/s were considered as optimal and were administered in five patients for 3D MR aortography. All images revealed clear delineation of the abdominal aorta and its major branches. Mean+/-SD of contrast-to-noise ratios of the abdominal aorta, common iliac and renal artery were 70.2+/-15.2, 58.6+/-12.3 and 67.4+/-12.3. Approximately seven intra-aortal injections would be permissible in patients during MR-guided interventions without exceeding the maximal dose of gadolinium.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15968517     DOI: 10.1007/s00330-005-2790-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Selective contrast-enhanced MR angiography.

Authors:  C Bos; H F Smits; C J Bakker; M A Viergever
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  Determination of optimal injection parameters for intraarterial gadolinium-enhanced MR angiography.

Authors:  R Frayne; R A Omary; O Unal; C M Strother
Journal:  J Vasc Interv Radiol       Date:  2000 Nov-Dec       Impact factor: 3.464

3.  Intraarterial contrast material-enhanced magnetic resonance angiography of the aortoiliac system.

Authors:  Christian Paetzel; Niels Zorger; Johannes Seitz; Markus Völk; Wolfgang R Nitz; Thomas Herold; Stefan Feuerbach; Markus Lenhart
Journal:  J Vasc Interv Radiol       Date:  2004-09       Impact factor: 3.464

4.  Multiphase-multistep gadolinium-enhanced MR angiography of the abdominal aorta and runoff vessels.

Authors:  S O Schoenberg; F J Londy; P Licato; D M Williams; T Wakefield; T L Chenevert
Journal:  Invest Radiol       Date:  2001-05       Impact factor: 6.016

5.  Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters.

Authors:  R A Omary; O Unal; D S Koscielski; R Frayne; F R Korosec; C A Mistretta; C M Strother; T M Grist
Journal:  J Vasc Interv Radiol       Date:  2000-09       Impact factor: 3.464

6.  Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography.

Authors:  K Y Ho; T Leiner; M W de Haan; A G Kessels; P J Kitslaar; J M van Engelshoven
Journal:  Radiology       Date:  1998-03       Impact factor: 11.105

7.  Validation of injection parameters for catheter-directed intraarterial gadolinium-enhanced MR angiography.

Authors:  Reed A Omary; Kevin P Henseler; Orhan Unal; Randall J Smith; Robert K Ryu; Scott A Resnick; Mark B Saker; Howard B Chrisman; Richard Frayne; J Paul Finn; Debiao Li; Thomas M Grist
Journal:  Acad Radiol       Date:  2002-02       Impact factor: 3.173

8.  MR-guided angioplasty of renal artery stenosis in a pig model: a feasibility study.

Authors:  R A Omary; R Frayne; O Unal; T Warner; F R Korosec; C A Mistretta; C M Strother; T M Grist
Journal:  J Vasc Interv Radiol       Date:  2000-03       Impact factor: 3.464

9.  Lower extremity: low-dose contrast agent intraarterial MR angiography in patients--initial results.

Authors:  Deniz Bilecen; Anja-Carina Schulte; Hanns G Heidecker; Markus Aschwanden; Rolf Huegli; Kurt A Jaeger; Wladimir Ostheim-Dzerowycz; Georg Bongartz
Journal:  Radiology       Date:  2004-11-24       Impact factor: 11.105

10.  Gadolinium-enhanced three-dimensional MR angiography of the aorta and peripheral arteries: evaluation of a multistation examination using two gadopentetate dimeglumine infusions.

Authors:  J P Earls; N H Patel; P A Smith; S DeSena; M H Meissner
Journal:  AJR Am J Roentgenol       Date:  1998-09       Impact factor: 3.959

View more
  3 in total

Review 1.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

Review 2.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10

Review 3.  Magnetic Resonance-Guided Passive Catheter Tracking for Endovascular Therapy.

Authors:  Fabio Settecase; Alastair J Martin; Prasheel Lillaney; Aaron Losey; Steven W Hetts
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

  3 in total