Literature DB >> 15348476

Preparation of Gd3+-containing polymer complex as a novel magnetic resonance signal-enhancing coating material.

Jian Guo1, Xiqun Jiang, Yong Hu, Changzheng Yang.   

Abstract

This study investigated the suitability of a Gd(3+)-containing polymer complex used as a magnetic resonance (MR) signal-enhancing coating material. The synthesis of the Gd>(3+)-containing polymer complex was done by conjugating N-(2-hydroxyethyl)ethylenediaminetriacetic acid (HEDTA) with poly (styrene-maleic acid) copolymer (SMA), followed by coordinating with Gd(3+). The characterizations of FT-IR, NMR and XPS confirmed that HEDTA was covalently attached to SMA and Gd(3+)-containing polymer complex was formed. Coating such Gd(3+)-containing polymer complex on the surface of polypropylene (PP) catheter was performed by solution coating method. The results of MR imaging experiments in vitro indicated that the PP catheter coated with this coating material showed strong MR signal in the vicinity of the catheter surface and a clear contrast between the catheter surface and background. Based on these results, a novel MR signal-enhancing coating material, which showed the great potentialities in making catheters for endovascular intervention, visible by MR imaging, can be developed.

Entities:  

Year:  2003        PMID: 15348476     DOI: 10.1023/a:1022849227694

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  5 in total

1.  Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications.

Authors:  P Caravan; J J Ellison; T J McMurry; R B Lauffer
Journal:  Chem Rev       Date:  1999-09-08       Impact factor: 60.622

Review 2.  Interventional and intraoperative MRI: a general overview of the field.

Authors:  F A Jolesz
Journal:  J Magn Reson Imaging       Date:  1998 Jan-Feb       Impact factor: 4.813

3.  MR-guided endovascular interventions: susceptibility-based catheter and near-real-time imaging technique.

Authors:  C J Bakker; R M Hoogeveen; W F Hurtak; J J van Vaals; M A Viergever; W P Mali
Journal:  Radiology       Date:  1997-01       Impact factor: 11.105

4.  Catheter visualization using locally induced, actively controlled field inhomogeneities.

Authors:  A Glowinski; G Adam; A Bücker; J Neuerburg; J J van Vaals; R W Günther
Journal:  Magn Reson Med       Date:  1997-08       Impact factor: 4.668

5.  Endovascular treatment of experimental canine aneurysms: feasibility with MR imaging guidance.

Authors:  C M Strother; O Unal; R Frayne; A Turk; R Omary; F R Korosec; C A Mistretta
Journal:  Radiology       Date:  2000-05       Impact factor: 11.105

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.