Literature DB >> 15900436

Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty.

T Gosens1, E J van Langelaan.   

Abstract

We used a proximally hydroxyapatite-coated femoral stem in revision arthroplasty of 48 cases with aseptic loosening and Paprosky defect class 1 or 2. We reviewed the outcome after 6.1 (4--9.3) years. The clinical outcome was good, with a mean postoperative HHS of 90 (51--100) points. There were five reoperations all on the acetabular side and none for the femoral stem. At follow-up, we observed cancellous sclerosis radiographically in 19 cases-especially in non-tightly fitted stems and mainly in Gruen zones 2 and 6. In 13 cases, cortical thickening was seen, mainly in Gruen zones 3 and 5 and especially in tightly fitted stems. These bony changes were significant and not related to any clinical parameter. They started to appear from 6 months onward, with increasing frequency with longer follow-up. We find that the standard Mallory-Head hydroxyapatite-coated femoral stem is suitable for revision in cases with lower-class femoral defects.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15900436      PMCID: PMC3474528          DOI: 10.1007/s00264-005-0659-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  22 in total

1.  Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty.

Authors:  W G Paprosky; N V Greidanus; J Antoniou
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

2.  A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem.

Authors:  M J Coathup; G W Blunn; N Flynn; C Williams; N P Thomas
Journal:  J Bone Joint Surg Br       Date:  2001-01

3.  Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss.

Authors:  A I A Rahmy; T Gosens; G M Blake; A Tonino; I Fogelman
Journal:  Osteoporos Int       Date:  2003-12-06       Impact factor: 4.507

4.  Reduction in cement-bone interface shear strength between primary and revision arthroplasty.

Authors:  Y Dohmae; J E Bechtold; R E Sherman; R M Puno; R B Gustilo
Journal:  Clin Orthop Relat Res       Date:  1988-11       Impact factor: 4.176

5.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

6.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

7.  Strength of the cement-bone interface.

Authors:  W R Krause; W Krug; J Miller
Journal:  Clin Orthop Relat Res       Date:  1982-03       Impact factor: 4.176

8.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

9.  The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study. The International ABG Study Group.

Authors:  A J Tonino; A I Rahmy
Journal:  J Arthroplasty       Date:  2000-04       Impact factor: 4.757

10.  Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem.

Authors:  A J Tonino; M Thèrin; C Doyle
Journal:  J Bone Joint Surg Br       Date:  1999-01
View more
  2 in total

1.  Distal locking stem for revision femoral loosening and peri-prosthetic fractures.

Authors:  Patrice Mertl; Remy Philippot; Philippe Rosset; Henri Migaud; Jacques Tabutin; Denis Van de Velde
Journal:  Int Orthop       Date:  2010-12-24       Impact factor: 3.075

2.  Long, titanium, cemented stems decreased late periprosthetic fractures and revisions in patients with severe bone loss and previous revision.

Authors:  Philippe Hernigou; Hernigou Philippe; Nicolas Dupuys; Dupuys Nicolas; Jerome Delambre; Delambre Jerome; Isaac Guissou; Guissou Isaac; Alexandre Poignard; Poignard Alexandre; Jerome Allain; Allain Jerome; Charles Henri Flouzat Lachaniette
Journal:  Int Orthop       Date:  2014-09-18       Impact factor: 3.075

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.