Literature DB >> 10723903

A system for investigating oesophageal photoplethysmographic signals in anaesthetised patients.

P A Kyriacou1, A R Moye, A Gregg, D M Choi, R M Langford, D P Jones.   

Abstract

The monitoring of arterial blood oxygen saturation in patients with compromised peripheral perfusion is often difficult, because conventional non-invasive techniques such as pulse oximetry (SpO2) can fail. Poor peripheral circulation commonly occurs after major surgery including cardiopulmonary bypass. The difficulties in these clinical situations might be overcome if the sensor were to monitor a better perfused central part of the body such as the oesophagus. A new oesophageal photoplethysmographic (PPG) probe and an isolated processing system have been developed to investigate the pulsatile signals of anaesthetised adult patients undergoing routine surgery. Measurements were made in the middle third of the oesophagus, 25 cm to 30 cm from the upper incisors. The AC PPG signals are sampled by a data acquisition system connected to a laptop computer. The signals recorded correspond to infrared and red AC PPGs from the middle third oesophagus and the finger. Preliminary results from 20 patients show that good quality AC PPG signals can be measured in the human oesophagus. The ratio of the oesophageal to finger AC PPG amplitudes was calculated for the infrared and red wavelengths for each patient. The mean (+/- standard deviation) of this ratio was 2.9 +/- 2.1 (n = 19) for the infrared wavelength and 3.1 +/- 2.4 (n = 16) for the red wavelength. The red and infrared wavelengths used are appropriate for pulse oximetry and this investigation indicates that the mid-oesophagus may be a suitable site for the reliable monitoring of SpO2 in patients with poor peripheral perfusion.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10723903     DOI: 10.1007/BF02513360

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  7 in total

1.  Nasal pulse oximetry overestimates oxygen saturation.

Authors:  J Rosenberg; M H Pedersen
Journal:  Anaesthesia       Date:  1990-12       Impact factor: 6.955

2.  A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion.

Authors:  D G Clayton; R K Webb; A C Ralston; D Duthie; W B Runciman
Journal:  Anaesthesia       Date:  1991-01       Impact factor: 6.955

3.  The successful use of transesophageal pulse oximetry in a patient in whom peripheral pulse oximetry was unobtainable.

Authors:  S E Borum
Journal:  Anesth Analg       Date:  1997-09       Impact factor: 5.108

Review 4.  Pulse oximetry: a review of the theory, accuracy, and clinical applications.

Authors:  W A Bowes; B C Corke; J Hulka
Journal:  Obstet Gynecol       Date:  1989-09       Impact factor: 7.661

5.  Randomized evaluation of pulse oximetry in 20,802 patients: I. Design, demography, pulse oximetry failure rate, and overall complication rate.

Authors:  J T Moller; T Pedersen; L S Rasmussen; P F Jensen; B D Pedersen; O Ravlo; N H Rasmussen; K Espersen; N W Johannessen; J B Cooper
Journal:  Anesthesiology       Date:  1993-03       Impact factor: 7.892

6.  A prospective study of intraoperative pulse oximetry failure.

Authors:  P R Freund; P T Overand; J Cooper; L Jacobson; S Bosse; B Walker; K L Posner; F W Cheney
Journal:  J Clin Monit       Date:  1991-07

7.  Predictors of pulse oximetry data failure.

Authors:  D L Reich; A Timcenko; C A Bodian; J Kraidin; J Hofman; M DePerio; S N Konstadt; T Kurki; J B Eisenkraft
Journal:  Anesthesiology       Date:  1996-04       Impact factor: 7.892

  7 in total
  2 in total

1.  Measuring venous oxygenation using the photoplethysmograph waveform.

Authors:  Zachary D Walton; Panayiotis A Kyriacou; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2010-07-20       Impact factor: 2.502

2.  In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?

Authors:  Stefanie Passler; Niklas Müller; Veit Senner
Journal:  Sensors (Basel)       Date:  2019-08-21       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.