Literature DB >> 2668828

Pulse oximetry: a review of the theory, accuracy, and clinical applications.

W A Bowes1, B C Corke, J Hulka.   

Abstract

Pulse oximetry has emerged as a clinical tool in anesthesia and newborn monitoring within the last 7 years as a result of recent technological and theoretical advances. Oximeters measure the different absorption spectra of oxygenated and deoxygenated hemoglobin. Electronic measures of oxygenation at the peak of the pulse allow computation and display of oxygen saturation of the arterial blood almost instantly. Correlation coefficients between pulse oximetry and direct blood oxygen saturation measurement range from 0.77-0.99 when oxygen saturation is greater than 60%. The method is noninvasive (a clip or tape on a finger), simple to operate, and adaptable to various patient populations. Pulse oximetry monitors continuously and instantaneously, is responsive to change, and is accurate. Factors adversely affecting the accuracy of pulse oximeter output include transducer movement, peripheral vasoconstriction, a nonpulsating vascular bed, hypotension, anemia, changes in systemic vascular resistance, hypothermia, presence of intravascular dyes, and nail polish. Pulse oximetry has been used to monitor oxygen saturation intraoperatively in the adult and neonatal intensive care units and to monitor pregnant patients and their infants at delivery. Once the advantages and limitations of pulse oximetry are recognized, this monitoring technique can play an important role in the care of patients with cardiovascular and respiratory compromise.

Entities:  

Mesh:

Year:  1989        PMID: 2668828

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  14 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

2.  A novel haemoglobin variant mimicking cyanotic congenital heart disease.

Authors:  Francisco Abecasis; Inês Marques; Celeste Bento; Anabela Ferrão
Journal:  BMJ Case Rep       Date:  2016-01-28

3.  Case-control studies of novel hemoglobin anomalies as differential diagnosis in sleep apnea syndrome.

Authors:  Berndt Zur; Michael Ludwig; Birgit Stoffel-Wagner
Journal:  Sleep Breath       Date:  2012-05-13       Impact factor: 2.816

4.  Pulse oximetry reference values at high altitude.

Authors:  J M Lozano; O R Duque; T Buitrago; S Behaine
Journal:  Arch Dis Child       Date:  1992-03       Impact factor: 3.791

5.  No protective role for hypoxic pulmonary vasoconstriction in severe hypergravity-induced arterial hypoxemia.

Authors:  Lars L Karlsson; Malin Rohdin; Michael Nekludov; Malin Ax; Johan Petersson
Journal:  Eur J Appl Physiol       Date:  2011-01-15       Impact factor: 3.078

6.  A system for investigating oesophageal photoplethysmographic signals in anaesthetised patients.

Authors:  P A Kyriacou; A R Moye; A Gregg; D M Choi; R M Langford; D P Jones
Journal:  Med Biol Eng Comput       Date:  1999-09       Impact factor: 2.602

7.  Utilization of pulse oximetry for the study of the inhibitory effects of antiviral agents on influenza virus in mice.

Authors:  R W Sidwell; J H Huffman; J Gilbert; B Moscon; G Pedersen; R Burger; R P Warren
Journal:  Antimicrob Agents Chemother       Date:  1992-02       Impact factor: 5.191

8.  Hypoxemia during oral feedings in adults with dysphagia and severe neurological disabilities.

Authors:  B Rogers; M Msall; D Shucard
Journal:  Dysphagia       Date:  1993       Impact factor: 3.438

9.  Vital signs monitoring during injectable and inhalant anesthesia in mice.

Authors:  Atsushi Tsukamoto; Kazuya Serizawa; Reiichiro Sato; Jumpei Yamazaki; Tomo Inomata
Journal:  Exp Anim       Date:  2014-10-10

10.  Initial and sustained brain responses to threat anticipation in blood-injection-injury phobia.

Authors:  Leonie Brinkmann; Hendrik Poller; Martin J Herrmann; Wolfgang Miltner; Thomas Straube
Journal:  Neuroimage Clin       Date:  2016-12-18       Impact factor: 4.881

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.