Modeling flow effects on thrombotic deposition in a membrane oxygenator.

M J Gartner1, C R Wilhelm, K L Gage, M C Fabrizio, W R Wagner.   

Abstract

The hypothesis that regions of low blood velocity in a membrane oxygenator, as predicted by computational fluid dynamics (CFD), would correspond with regions of clinical thrombotic deposition was investigated. Twenty heparin-coated oxygenators were sectioned following use in adult extracorporeal membrane oxygenation. The activated clotting time (ACT) was maintained at approximately 180 s via heparin infusion throughout the support period. Cross-sections were systematically photographed, and slides made to allow image projection upon a digitizing pad. Thrombotic deposition was traced to allow creation of a device cross-section image with an overlaid color scale representing thrombotic deposition frequency. A two-dimensional CFD model was developed to predict blood velocities throughout the oxygenator cross-section. Direct spatial comparisons were made between maps of CFD modeled blood speed and thrombotic deposition. Theoretical oxygenator design modification was performed within the CFD model to investigate flow paths which might minimize regions of low blood velocity. CFD results demonstrated that low velocity regions qualitatively matched regions with a high incidence of thrombotic deposition. Thrombotic deposition was also correlated to longer perfusion periods. This technique of coupling clinical data and CFD offers the potential to relate flow characteristics to thrombotic deposition and represents a potentially powerful new methodology for the optimization of oxygenator flow-related biocompatibility.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10677154     DOI: 10.1046/j.1525-1594.2000.06384.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  17 in total

1.  Evaluation of local gas exchange in a pulsating respiratory support catheter.

Authors:  Heide J Eash; Brian J Frankowski; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2005 Mar-Apr       Impact factor: 2.872

2.  Computational study of the blood flow in three types of 3D hollow fiber membrane bundles.

Authors:  Jiafeng Zhang; Xiaobing Chen; Jun Ding; Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  J Biomech Eng       Date:  2013-12       Impact factor: 2.097

3.  Darcy Permeability of Hollow Fiber Bundles Used in Blood Oxygenation Devices.

Authors:  Heather E Pacella; Heidi J Eash; William J Federspiel
Journal:  J Memb Sci       Date:  2011-10-15       Impact factor: 8.742

Review 4.  In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Authors:  Deepika N Sarode; Shuvo Roy
Journal:  Expert Rev Med Devices       Date:  2019-06-10       Impact factor: 3.166

5.  Computational evaluation of the thrombogenic potential of a hollow-fiber oxygenator with integrated heat exchanger during extracorporeal circulation.

Authors:  Alessandra Pelosi; Jawaad Sheriff; Marco Stevanella; Gianfranco B Fiore; Danny Bluestein; Alberto Redaelli
Journal:  Biomech Model Mechanobiol       Date:  2012-10-06

6.  Hemodynamic effects of pumpless extracorporeal membrane oxygenation (ECMO) support for chronically pressure-overloaded right heart failure in a canine experimental model.

Authors:  Kiyokazu Tamesue; Sugato Nawa; Shingo Ichiba; Motoi Aoe; Hiroshi Date; Nobuyoshi Shimizu
Journal:  Surg Today       Date:  2005       Impact factor: 2.549

7.  Micro-scale Modeling of Flow and Oxygen Transfer in Hollow Fiber Membrane Bundle.

Authors:  M Ertan Taskin; Katharine H Fraser; Tao Zhang; Bartley P Griffith; Zhongjun J Wu
Journal:  J Memb Sci       Date:  2010-10-15       Impact factor: 8.742

8.  Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter.

Authors:  R Garrett Jeffries; Brian J Frankowski; Greg W Burgreen; William J Federspiel
Journal:  Artif Organs       Date:  2014-04-22       Impact factor: 3.094

9.  Darcy Permeability of Hollow Fiber Membrane Bundles Made from Membrana Polymethylpentene Fibers Used in Respiratory Assist Devices.

Authors:  Shalv P Madhani; Brandon D D'Aloiso; Brian Frankowski; William J Federspiel
Journal:  ASAIO J       Date:  2016 May-Jun       Impact factor: 2.872

Review 10.  Advances in extracorporeal membrane oxygenator design for artificial placenta technology.

Authors:  David G Blauvelt; Emily N Abada; Peter Oishi; Shuvo Roy
Journal:  Artif Organs       Date:  2020-11-04       Impact factor: 3.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.