Literature DB >> 24749994

Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter.

R Garrett Jeffries1, Brian J Frankowski, Greg W Burgreen, William J Federspiel.   

Abstract

Providing partial respiratory assistance by removing carbon dioxide (CO2 ) can improve clinical outcomes in patients suffering from acute exacerbations of chronic obstructive pulmonary disease and acute respiratory distress syndrome. An intravenous respiratory assist device with a small (25 Fr) insertion diameter eliminates the complexity and potential complications associated with external blood circuitry and can be inserted by nonspecialized surgeons. The impeller percutaneous respiratory assist catheter (IPRAC) is a highly efficient CO2 removal device for percutaneous insertion to the vena cava via the right jugular or right femoral vein that utilizes an array of impellers rotating within a hollow-fiber membrane bundle to enhance gas exchange. The objective of this study was to evaluate the effects of new impeller designs and impeller spacing on gas exchange in the IPRAC using computational fluid dynamics (CFD) and in vitro deionized water gas exchange testing. A CFD gas exchange and flow model was developed to guide a progressive impeller design process. Six impeller blade geometries were designed and tested in vitro in an IPRAC device with 2- or 10-mm axial spacing and varying numbers of blades (2-5). The maximum CO2 removal efficiency (exchange per unit surface area) achieved was 573 ± 8 mL/min/m(2) (40.1 mL/min absolute). The gas exchange rate was found to be largely independent of blade design and number of blades for the impellers tested but increased significantly (5-10%) with reduced axial spacing allowing for additional shaft impellers (23 vs. 14). CFD gas exchange predictions were within 2-13% of experimental values and accurately predicted the relative improvement with impellers at 2- versus 10-mm axial spacing. The ability of CFD simulation to accurately forecast the effects of influential design parameters suggests it can be used to identify impeller traits that profoundly affect facilitated gas exchange.
Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Acute respiratory distress syndrome; Artificial lungs; Blood oxygenator; CO2 removal; Chronic obstructive pulmonary disease; Gas exchange; Impeller design

Mesh:

Substances:

Year:  2014        PMID: 24749994      PMCID: PMC4206686          DOI: 10.1111/aor.12308

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  31 in total

1.  Venoarterial extracorporeal membrane oxygenation (VA-ECMO) in pediatric cardiac support.

Authors:  Vinod H Thourani; Paul M Kirshbom; Kirk R Kanter; Janet Simsic; Brian E Kogon; Scott Wagoner; Francine Dykes; James Fortenberry; Joseph M Forbess
Journal:  Ann Thorac Surg       Date:  2006-07       Impact factor: 4.330

Review 2.  Extracorporeal carbon dioxide removal: the future of lung support lies in the history.

Authors:  Manish Kaushik; Marzena Wojewodzka-Zelezniakowicz; Dinna N Cruz; A Ferrer-Nadal; Catarina Teixeira; Elena Iglesias; Jeong Chul Kim; Antonio Braschi; Pasquale Piccinni; Claudio Ronco
Journal:  Blood Purif       Date:  2012-10-24       Impact factor: 2.614

3.  Computer-assisted numerical analysis for oxygen and carbon dioxide mass transfer in blood oxygenators.

Authors:  Fabio Turri; Jurandir Itizo Yanagihara
Journal:  Artif Organs       Date:  2011-06       Impact factor: 3.094

4.  Conceptual and design features of a practical, clinically effective intravenous mechanical blood oxygen/carbon dioxide exchange device (IVOX).

Authors:  J D Mortensen; G Berry
Journal:  Int J Artif Organs       Date:  1989-06       Impact factor: 1.595

5.  Compact cross-flow tubular oxygenators.

Authors:  L F Mockros; R Leonard
Journal:  Trans Am Soc Artif Intern Organs       Date:  1985

6.  Respiratory dialysis: reduction in dependence on mechanical ventilation by venovenous extracorporeal CO2 removal.

Authors:  Andriy I Batchinsky; Bryan S Jordan; Dara Regn; Corina Necsoiu; William J Federspiel; Michael J Morris; Leopoldo C Cancio
Journal:  Crit Care Med       Date:  2011-06       Impact factor: 7.598

Review 7.  Low blood flow extracorporeal carbon dioxide removal (ECCO2R): a review of the concept and a case report.

Authors:  N M Habashi; U R Borg; H N Reynolds
Journal:  Intensive Care Med       Date:  1995-07       Impact factor: 17.440

8.  Compact intra- and extracorporeal oxygenator developments.

Authors:  Giorgio Cattaneo; Andreas Strauss; Helmut Reul
Journal:  Perfusion       Date:  2004-07       Impact factor: 1.972

9.  Outcome of patients undergoing prolonged mechanical ventilation after critical illness.

Authors:  Luca M Bigatello; Henry Thomas Stelfox; Lorenzo Berra; Ulrich Schmidt; Elise M Gettings
Journal:  Crit Care Med       Date:  2007-11       Impact factor: 7.598

10.  Computational Fluid Dynamics and Experimental Characterization of the Pediatric Pump-Lung.

Authors:  Zhongjun J Wu; Barry Gellman; Tao Zhang; M Ertan Taskin; Kurt A Dasse; Bartley P Griffith
Journal:  Cardiovasc Eng Technol       Date:  2011-12-01       Impact factor: 2.495

View more
  6 in total

1.  Kinetics of CO2 exchange with carbonic anhydrase immobilized on fiber membranes in artificial lungs.

Authors:  D T Arazawa; J D Kimmel; W J Federspiel
Journal:  J Mater Sci Mater Med       Date:  2015-06-02       Impact factor: 3.896

2.  Fiber Bundle Design for an Integrated Wearable Artificial Lung.

Authors:  Shalv P Madhani; Brian J Frankowski; William J Federspiel
Journal:  ASAIO J       Date:  2017 Sep/Oct       Impact factor: 2.872

3.  Darcy Permeability of Hollow Fiber Membrane Bundles Made from Membrana Polymethylpentene Fibers Used in Respiratory Assist Devices.

Authors:  Shalv P Madhani; Brandon D D'Aloiso; Brian Frankowski; William J Federspiel
Journal:  ASAIO J       Date:  2016 May-Jun       Impact factor: 2.872

4.  An extracorporeal carbon dioxide removal (ECCO2R) device operating at hemodialysis blood flow rates.

Authors:  R Garrett Jeffries; Laura Lund; Brian Frankowski; William J Federspiel
Journal:  Intensive Care Med Exp       Date:  2017-09-06

5.  Water as a Blood Model for Determination of CO2 Removal Performance of Membrane Oxygenators.

Authors:  Benjamin Lukitsch; Raffael Koller; Paul Ecker; Martin Elenkov; Christoph Janeczek; Markus Pekovits; Bahram Haddadi; Christian Jordan; Margit Gfoehler; Michael Harasek
Journal:  Membranes (Basel)       Date:  2021-05-12

6.  Acidic sweep gas with carbonic anhydrase coated hollow fiber membranes synergistically accelerates CO2 removal from blood.

Authors:  D T Arazawa; J D Kimmel; M C Finn; W J Federspiel
Journal:  Acta Biomater       Date:  2015-07-06       Impact factor: 8.947

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.