Darcy Permeability of Hollow Fiber Membrane Bundles Made from Membrana Polymethylpentene Fibers Used in Respiratory Assist Devices.

Shalv P Madhani1, Brandon D D'Aloiso, Brian Frankowski, William J Federspiel.   

Abstract

Hollow fiber membranes (HFMs) are used in blood oxygenators for cardiopulmonary bypass or in next generation artificial lungs. Flow analyses of these devices is typically done using computational fluid dynamics (CFD) modeling HFM bundles as porous media, using a Darcy permeability coefficient estimated from the Blake-Kozeny (BK) equation to account for viscous drag from fibers. We recently published how well this approach can predict Darcy permeability for fiber bundles made from polypropylene HFMs, showing the prediction can be significantly improved using an experimentally derived correlation between the BK constant (A) and bundle porosity (ε). In this study, we assessed how well our correlation for A worked for predicting the Darcy permeability of fiber bundles made from Membrana polymethylpentene (PMP) HFMs, which are increasingly being used clinically. Swatches in the porosity range of 0.4 to 0.8 were assessed in which sheets of fiber were stacked in parallel, perpendicular, and angled configurations. Our previously published correlation predicted Darcy within ±8%. A new correlation based on current and past measured permeability was determined: A = 497ε - 103; using this correlation measured Darcy permeability was within ±6%. This correlation varied from 8% to -3.5% of our prior correlation over the tested porosity range.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26809086      PMCID: PMC4850091          DOI: 10.1097/MAT.0000000000000348

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  16 in total

1.  Computational model-based design of a wearable artificial pump-lung for cardiopulmonary/respiratory support.

Authors:  Zhongjun J Wu; M Ertan Taskin; Tao Zhang; Katharine H Fraser; Bartley P Griffith
Journal:  Artif Organs       Date:  2011-12-06       Impact factor: 3.094

2.  Computational fluid flow and mass transfer of a functionally integrated pediatric pump-oxygenator configuration.

Authors:  Brian Fill; Mark Gartner; Greg Johnson; Marc Horner; Jeff Ma
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

3.  A novel wearable pump-lung device: in vitro and acute in vivo study.

Authors:  Tao Zhang; Xufeng Wei; Giacomo Bianchi; Philip M Wong; Brian Biancucci; Bartley P Griffith; Zhongjun J Wu
Journal:  J Heart Lung Transplant       Date:  2011-10-20       Impact factor: 10.247

Review 4.  Artificial lungs: are we there yet?

Authors:  Martin Strueber
Journal:  Thorac Surg Clin       Date:  2015       Impact factor: 1.750

5.  Darcy Permeability of Hollow Fiber Bundles Used in Blood Oxygenation Devices.

Authors:  Heather E Pacella; Heidi J Eash; William J Federspiel
Journal:  J Memb Sci       Date:  2011-10-15       Impact factor: 8.742

6.  First experience with the new portable extracorporeal membrane oxygenation system Cardiohelp for severe respiratory failure in adults.

Authors:  A Haneya; A Philipp; M Foltan; D Camboni; T Müeller; T Bein; C Schmid; M Lubnow
Journal:  Perfusion       Date:  2012-01-16       Impact factor: 1.972

7.  Efficiency of gas transfer in venovenous extracorporeal membrane oxygenation: analysis of 317 cases with four different ECMO systems.

Authors:  Karla Lehle; Alois Philipp; Karl-Anton Hiller; Florian Zeman; Dirk Buchwald; Christof Schmid; Christian Dornia; Dirk Lunz; Thomas Müller; Matthias Lubnow
Journal:  Intensive Care Med       Date:  2014-10-17       Impact factor: 17.440

8.  Development of a miniaturized heart-lung machine for neonates with congenital heart defect.

Authors:  Jutta Arens; Heike Schnöring; Fabian Reisch; Jaime F Vázquez-Jiménez; Thomas Schmitz-Rode; Ulrich Steinseifer
Journal:  ASAIO J       Date:  2008 Sep-Oct       Impact factor: 2.872

9.  Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter.

Authors:  R Garrett Jeffries; Brian J Frankowski; Greg W Burgreen; William J Federspiel
Journal:  Artif Organs       Date:  2014-04-22       Impact factor: 3.094

10.  Design and in vitro assessment of an improved, low-resistance compliant thoracic artificial lung.

Authors:  Rebecca E Schewe; Khalil M Khanafer; Aarthi Arab; Jeffrey A Mitchell; David J Skoog; Keith E Cook
Journal:  ASAIO J       Date:  2012 Nov-Dec       Impact factor: 2.872

View more
  3 in total

1.  Early in vivo experience with the pediatric continuous-flow total artificial heart.

Authors:  Jamshid H Karimov; David J Horvath; Nicole Byram; Gengo Sunagawa; Barry D Kuban; Shengqiang Gao; Raymond Dessoffy; Kiyotaka Fukamachi
Journal:  J Heart Lung Transplant       Date:  2018-03-30       Impact factor: 10.247

2.  In Vitro Characterization of the Pittsburgh Pediatric Ambulatory Lung.

Authors:  Ryan A Orizondo; Alexandra G May; Shalv P Madhani; Brian J Frankowski; Greg W Burgreen; Peter D Wearden; William J Federspiel
Journal:  ASAIO J       Date:  2018 Nov/Dec       Impact factor: 2.872

3.  Low-Resistance, Concentric-Gated Pediatric Artificial Lung for End-Stage Lung Failure.

Authors:  Alex J Thompson; Skylar Buchan; Benjamin Carr; Clinton Poling; McKenzie Hayes; Uditha Piyumindri Fernando; Andreas Kaesler; Peter Schlanstein; Felix Hesselmann; Jutta Arens; Joseph A Potkay; Alvaro Rojas-PeÑa; Robert H Bartlett; Ronald B Hirschl
Journal:  ASAIO J       Date:  2020-04       Impact factor: 3.826

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.