Literature DB >> 31154869

In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Deepika N Sarode1, Shuvo Roy1.   

Abstract

INTRODUCTION: Blood-recirculating medical devices, such as mechanical circulatory support (MCS), extracorporeal membrane oxygenators (ECMO), and hemodialyzers, are commonly used to treat or improve quality of life in patients with cardiac, pulmonary, and renal failure, respectively. As part of their regulatory approval, guidelines for thrombosis evaluation in pre-clinical development have been established. In vitro testing evaluates a device's potential to produce thrombosis markers in static and dynamic flow loops. AREAS COVERED: This review focuses on in vitro static and dynamic models to assess thrombosis in blood-recirculating medical devices. A summary of key devices is followed by a review of molecular markers of contact activation. Current thrombosis testing guidance documents, ISO 10993-4, ASTM F-2888, and F-2382 will be discussed, followed by analysis of their application to in vitro testing models. EXPERT OPINION: In general, researchers have favored in vivo models to thoroughly evaluate thrombosis, limiting in vitro evaluation to hemolysis. In vitro studies are not standardized and it is often difficult to compare studies on similar devices. As blood-recirculating devices have advanced to include wearable and implantable artificial organs, expanded guidelines standardizing in vitro testing are needed to identify the thrombotic potential without excessive use of in vivo resources during pre-clinical development.

Entities:  

Keywords:  Blood compatibility; blood-recirculating medical devices; dynamic thrombosis models; hemocompatibility models; static thrombosis models; thrombogenicity; thrombosis

Mesh:

Substances:

Year:  2019        PMID: 31154869      PMCID: PMC6660015          DOI: 10.1080/17434440.2019.1627199

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  99 in total

1.  In vitro evaluation of the heparin-coated Gyro C1E3 blood pump.

Authors:  K Muramatsu; T Masuoka; A Fujisawa
Journal:  Artif Organs       Date:  2001-07       Impact factor: 3.094

2.  Surface coating of stearyl poly(ethylene oxide) coupling-polymer on polyurethane guiding catheters with poly(ether urethane) film-building additive for biomedical applications.

Authors:  D A Wang; J Ji; C Y Gao; G H Yu; L X Feng
Journal:  Biomaterials       Date:  2001-06       Impact factor: 12.479

3.  Adhesion and spreading of cells on charged surfaces.

Authors:  N G Maroudas
Journal:  J Theor Biol       Date:  1975-02       Impact factor: 2.691

4.  Lysine-derivatized polyurethane as a clot lysing surface: conversion of adsorbed plasminogen to plasmin and clot lysis in vitro.

Authors:  W G McClung; D L Clapper; S P Hu; J L Brash
Journal:  Biomaterials       Date:  2001-07       Impact factor: 12.479

5.  Modeling flow effects on thrombotic deposition in a membrane oxygenator.

Authors:  M J Gartner; C R Wilhelm; K L Gage; M C Fabrizio; W R Wagner
Journal:  Artif Organs       Date:  2000-01       Impact factor: 3.094

6.  Platelet activation in the gyro C1E3 centrifugal pump: comparison with the terumo capiox and the Nikkiso HPM-15.

Authors:  K Kawahito; H Adachi; T Ino
Journal:  Artif Organs       Date:  2000-11       Impact factor: 3.094

7.  Platelet adhesion to polystyrene-based surfaces preadsorbed with plasmas selectively depleted in fibrinogen, fibronectin, vitronectin, or von Willebrand's factor.

Authors:  Wei-Bor Tsai; John M Grunkemeier; Clive D McFarland; Thomas A Horbett
Journal:  J Biomed Mater Res       Date:  2002-06-05

8.  In vitro comparative evaluation under static conditions of the hemocompatibility of four types of tubing for cardiopulmonary bypass.

Authors:  M F Harmand; F Briquet
Journal:  Biomaterials       Date:  1999-09       Impact factor: 12.479

Review 9.  Platelets, leukocytes, and coagulation.

Authors:  B A Bouchard; P B Tracy
Journal:  Curr Opin Hematol       Date:  2001-09       Impact factor: 3.284

10.  Formation of polymerized mixed heparin/albumin surface layer and cellular adhesional responses.

Authors:  Tomoko Magoshi; Takehisa Matsuda
Journal:  Biomacromolecules       Date:  2002 Sep-Oct       Impact factor: 6.988

View more
  2 in total

1.  An enduring in vitro wound healing phase recipient by bioactive glass-graphene oxide nanocomposites.

Authors:  Manjubaashini Nandhakumar; Daniel Thangadurai Thangaian; Senthilarasu Sundaram; Anurag Roy; Balakumar Subramanian
Journal:  Sci Rep       Date:  2022-09-28       Impact factor: 4.996

Review 2.  Control of Blood Coagulation by Hemocompatible Material Surfaces-A Review.

Authors:  Janna Kuchinka; Christian Willems; Dmitry V Telyshev; Thomas Groth
Journal:  Bioengineering (Basel)       Date:  2021-12-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.