Literature DB >> 10659736

Efficient correction for CT image artifacts caused by objects extending outside the scan field of view.

B Ohnesorge1, T Flohr, K Schwarz, J P Heiken, K T Bae.   

Abstract

The purpose of this paper is to develop a method of eliminating CT image artifacts generated by objects extending outside the scan field of view, such as obese or inadequately positioned patients. CT projection data are measured only within the scan field of view and thus are abruptly discontinuous at the projection boundaries if the scanned object extends outside the scan field of view. This data discontinuity causes an artifact that consists of a bright peripheral band that obscures objects near the boundary of the scan field of view. An adaptive mathematical extrapolation scheme with low computational expense was applied to reduce the data discontinuity prior to convolution in a filtered backprojection reconstruction. Despite extended projection length, the convolution length was not increased and thus the reconstruction time was not affected. Raw projection data from ten patients whose bodies extended beyond the scan field of view were reconstructed using a conventional method and our extended reconstruction method. Limitations of the algorithm are investigated and extensions for further improvement are discussed. The images reconstructed by conventional filtered backprojection demonstrated peripheral bright-band artifacts near the boundary of the scan field of view. Images reconstructed with our technique were free of such artifacts and clearly showed the anatomy at the periphery of the scan field of view with correct attenuation values. We conclude that bright-band artifacts generated by obese patients whose bodies extend beyond the scan field of view were eliminated with our reconstruction method, which reduces boundary data discontinuity. The algorithm can be generalized to objects with inhomogeneous peripheral density and to true "Region of Interest Reconstruction" from truncated projections.

Entities:  

Mesh:

Year:  2000        PMID: 10659736     DOI: 10.1118/1.598855

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  42 in total

1.  Soft tissue variations influence HR-pQCT density measurements in a spatially dependent manner.

Authors:  Po-Hung Wu; Tanvi Gupta; Hanling Chang; Dimitry Petrenko; Anne Schafer; Galateia Kazakia
Journal:  Bone       Date:  2020-06-27       Impact factor: 4.398

2.  [Current status and future potentials of multislice computed tomography].

Authors:  T Flohr; B Ohnesorge; S Schaller
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

3.  Strategy of computed tomography sinogram inpainting based on sinusoid-like curve decomposition and eigenvector-guided interpolation.

Authors:  Yinsheng Li; Yang Chen; Yining Hu; Ahmed Oukili; Limin Luo; Wufan Chen; Christine Toumoulin
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2012-01-01       Impact factor: 2.129

4.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

5.  Reconstruction from truncated projections in CT using adaptive detruncation.

Authors:  K Sourbelle; M Kachelriess; W A Kalender
Journal:  Eur Radiol       Date:  2005-02-09       Impact factor: 5.315

Review 6.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

7.  Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy.

Authors:  Seungryong Cho; Erik Pearson; Charles A Pelizzari; Xiaochuan Pan
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

8.  Truncation correction for oblique filtering lines.

Authors:  Stefan Hoppe; Joachim Hornegger; Günter Lauritsch; Frank Dennerlein; Frédéric Noo
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  CONRAD--a software framework for cone-beam imaging in radiology.

Authors:  Andreas Maier; Hannes G Hofmann; Martin Berger; Peter Fischer; Chris Schwemmer; Haibo Wu; Kerstin Müller; Joachim Hornegger; Jang-Hwan Choi; Christian Riess; Andreas Keil; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

10.  Optimization-based image reconstruction with artifact reduction in C-arm CBCT.

Authors:  Dan Xia; David A Langan; Stephen B Solomon; Zheng Zhang; Buxin Chen; Hao Lai; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.