Literature DB >> 22218362

Strategy of computed tomography sinogram inpainting based on sinusoid-like curve decomposition and eigenvector-guided interpolation.

Yinsheng Li1, Yang Chen, Yining Hu, Ahmed Oukili, Limin Luo, Wufan Chen, Christine Toumoulin.   

Abstract

Projection incompleteness in x-ray computed tomography (CT) often relates to sparse sampling or detector gaps and leads to degraded reconstructions with severe streak and ring artifacts. To suppress these artifacts, this study develops a new sinogram inpainting strategy based on sinusoid-like curve decomposition and eigenvector-guided interpolation, where each missing sinogram point is considered located within a group of sinusoid-like curves and estimated from eigenvector-guided interpolation to preserve the sinogram texture continuity. The proposed approach is evaluated on real two-dimensional fan-beam CT data, for which the projection incompleteness, due to sparse sampling and symmetric detector gaps, is simulated. A Compute Unified Device Architecture (CUDA)-based parallelization is applied on the operations of sinusoid fittings and interpolations to accelerate the algorithm. A comparative study is then conducted to evaluate the proposed approach with two other inpainting methods and with a compressed sensing iterative reconstruction. Qualitative and quantitative performances demonstrate that the proposed approach can lead to efficient artifact suppression and less structure blurring.

Mesh:

Year:  2012        PMID: 22218362      PMCID: PMC3482203          DOI: 10.1364/JOSAA.29.000153

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  12 in total

1.  Efficient correction for CT image artifacts caused by objects extending outside the scan field of view.

Authors:  B Ohnesorge; T Flohr; K Schwarz; J P Heiken; K T Bae
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  Extension of the reconstruction field of view and truncation correction using sinogram decomposition.

Authors:  Alexander A Zamyatin; Satoru Nakanishi
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

3.  Statistical image reconstruction for inconsistent CT projection data.

Authors:  Thorsten Buzug; May Oehler
Journal:  Methods Inf Med       Date:  2007       Impact factor: 2.176

4.  CT truncation artifact removal using water-equivalent thicknesses derived from truncated projection data.

Authors:  Jonathan S Maltz; Supratik Bose; Himanshu P Shukla; Ali R Bani-Hashemi
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

5.  Suppression of metal artifacts in CT using a reconstruction procedure that combines MAP and projection completion.

Authors:  Catherine Lemmens; David Faul; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2009-02       Impact factor: 10.048

6.  Directional view interpolation for compensation of sparse angular sampling in cone-beam CT.

Authors:  Matthias Bertram; Jens Wiegert; Dirk Schafer; Til Aach; Georg Rose
Journal:  IEEE Trans Med Imaging       Date:  2009-01-06       Impact factor: 10.048

7.  Artifact reduction in truncated CT using Sinogram completion.

Authors:  R Chityala; K R Hoffmann; S Rudin; D R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005-02

8.  View sampling requirements in fan beam computed tomography.

Authors:  P M Joseph; R A Schulz
Journal:  Med Phys       Date:  1980 Nov-Dec       Impact factor: 4.071

9.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Authors:  Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2008-08-13       Impact factor: 3.609

10.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms.

Authors:  Jie Tang; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-09-09       Impact factor: 3.609

View more
  5 in total

1.  An Inter-Projection Interpolation (IPI) Approach with Geometric Model Restriction to Reduce Image Dose in Cone Beam CT (CBCT).

Authors:  Hong Zhang; Fengchong Kong; Lei Ren; Jian-Yue Jin
Journal:  Comput Model Objects Present Images (2014)       Date:  2014-09

2.  Hepatic dual-contrast CT imaging: slow triple kVp switching CT with CNN-based sinogram completion and material decomposition.

Authors:  Wenchao Cao; Nadav Shapira; Andrew Maidment; Heiner Daerr; Peter B Noël
Journal:  J Med Imaging (Bellingham)       Date:  2022-01-31

3.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

4.  Metal Artifact Reduction in Dental Computed Tomography Images Based on Sinogram Segmentation Using Curvelet Transform Followed by Hough Transform.

Authors:  Mehran Yazdi; Maryam Mohammadi
Journal:  J Med Signals Sens       Date:  2017 Jul-Sep

5.  A convolutional neural network for fast upsampling of undersampled tomograms in X-ray CT time-series using a representative highly sampled tomogram.

Authors:  Dimitrios Bellos; Mark Basham; Tony Pridmore; Andrew P French
Journal:  J Synchrotron Radiat       Date:  2019-04-23       Impact factor: 2.616

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.