Literature DB >> 15702338

Reconstruction from truncated projections in CT using adaptive detruncation.

K Sourbelle1, M Kachelriess, W A Kalender.   

Abstract

If the object exceeds the field of measurement (FOM) of a given CT scanner, severe artifacts may result. In this work, we propose an adaptive detruncation (ADT) method to reconstruct images from medical CT projections which are truncated in the transaxial direction. The truncated projections are extrapolated by estimating the convex hull of the patient. The ADT method allows us not only to achieve artifact-free images in the FOM but also to extend the images beyond the FOM, and can therefore be very attractive, for example, in PET/CT scanners for attenuation correction.

Entities:  

Mesh:

Year:  2005        PMID: 15702338     DOI: 10.1007/s00330-004-2621-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  4 in total

1.  Efficient correction for CT image artifacts caused by objects extending outside the scan field of view.

Authors:  B Ohnesorge; T Flohr; K Schwarz; J P Heiken; K T Bae
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  Truncation artifact reduction in transmission CT for improved SPECT attenuation compensation.

Authors:  D J Kadrmas; R J Jaszczak; J W McCormick; R E Coleman; C B Lim
Journal:  Phys Med Biol       Date:  1995-06       Impact factor: 3.609

3.  Processing of incomplete measurement data in computed tomography.

Authors:  R M Lewitt
Journal:  Med Phys       Date:  1979 Sep-Oct       Impact factor: 4.071

4.  Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

Authors:  Marc Kachelriess; Dirk-Alexander Sennst; Wolfgang Maxlmoser; Willi A Kalender
Journal:  Med Phys       Date:  2002-07       Impact factor: 4.071

  4 in total
  13 in total

Review 1.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

Review 2.  [Basic principles of flat detector computed tomography (FD-CT)].

Authors:  Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

3.  Statistical projection completion in X-ray CT using consistency conditions.

Authors:  Jingyan Xu; Katsuyuki Taguchi; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2010-05-03       Impact factor: 10.048

4.  Scaling calibration in region of interest reconstruction with the 1D and 2D ATRACT algorithm.

Authors:  Yan Xia; Frank Dennerlein; Sebastian Bauer; Hannes Hofmann; Joachim Hornegger; Andreas Maier
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-01-23       Impact factor: 2.924

Review 5.  Applications of artificial intelligence in nuclear medicine image generation.

Authors:  Zhibiao Cheng; Junhai Wen; Gang Huang; Jianhua Yan
Journal:  Quant Imaging Med Surg       Date:  2021-06

6.  Benefit of iodine density images to reduce out-of-field image artifacts at rapid kVp switching dual-energy CT.

Authors:  Brandan Dotson; Jack W Lambert; Zhen J Wang; Yuxin Sun; Michael A Ohliger; Sebastian Winklhofer; Benjamin M Yeh
Journal:  Abdom Radiol (NY)       Date:  2017-03

7.  Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2012-04-05       Impact factor: 3.609

8.  Optimization-based image reconstruction with artifact reduction in C-arm CBCT.

Authors:  Dan Xia; David A Langan; Stephen B Solomon; Zheng Zhang; Buxin Chen; Hao Lai; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

9.  A diffusion-based truncated projection artifact reduction method for iterative digital breast tomosynthesis reconstruction.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Lubomir M Hadjiiski
Journal:  Phys Med Biol       Date:  2013-01-14       Impact factor: 3.609

10.  Artifact reduction methods for truncated projections in iterative breast tomosynthesis reconstruction.

Authors:  Yiheng Zhang; Heang-Ping Chan; Berkman Sahiner; Jun Wei; Chuan Zhou; Lubomir M Hadjiiski
Journal:  J Comput Assist Tomogr       Date:  2009 May-Jun       Impact factor: 1.826

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.