Literature DB >> 19175146

Truncation correction for oblique filtering lines.

Stefan Hoppe1, Joachim Hornegger, Günter Lauritsch, Frank Dennerlein, Frédéric Noo.   

Abstract

State-of-the-art filtered backprojection (FBP) algorithms often define the filtering operation to be performed along oblique filtering lines in the detector. A limited scan field of view leads to the truncation of those filtering lines, which causes artifacts in the final reconstructed volume. In contrast to the case where filtering is performed solely along the detector rows, no methods are available for the case of oblique filtering lines. In this work, the authors present two novel truncation correction methods which effectively handle data truncation in this case. Method 1 (basic approach) handles data truncation in two successive preprocessing steps by applying a hybrid data extrapolation method, which is a combination of a water cylinder extrapolation and a Gaussian extrapolation. It is independent of any specific reconstruction algorithm. Method 2 (kink approach) uses similar concepts for data extrapolation as the basic approach but needs to be integrated into the reconstruction algorithm. Experiments are presented from simulated data of the FORBILD head phantom, acquired along a partial-circle-plus-arc trajectory. The theoretically exact M-line algorithm is used for reconstruction. Although the discussion is focused on theoretically exact algorithms, the proposed truncation correction methods can be applied to any FBP algorithm that exposes oblique filtering lines.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19175146      PMCID: PMC2673607          DOI: 10.1118/1.3002416

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry.

Authors:  X Wang; R Ning
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Efficient correction for CT image artifacts caused by objects extending outside the scan field of view.

Authors:  B Ohnesorge; T Flohr; K Schwarz; J P Heiken; K T Bae
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

3.  Methods for improving limited field-of-view radiotherapy reconstructions using imperfect a priori images.

Authors:  Kenneth J Ruchala; Gustavo H Olivera; Jeffrey M Kapatoes; Paul J Reckwerdt; Thomas R Mackie
Journal:  Med Phys       Date:  2002-11       Impact factor: 4.071

4.  Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage.

Authors:  Marc Kachelriess; Michael Knaup; Willi A Kalender
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

5.  Image reconstruction for the circle and line trajectory.

Authors:  Alexander Katsevich
Journal:  Phys Med Biol       Date:  2004-11-21       Impact factor: 3.609

6.  A novel reconstruction algorithm to extend the CT scan field-of-view.

Authors:  J Hsieh; E Chao; J Thibault; B Grekowicz; A Horst; S McOlash; T J Myers
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

7.  Image reconstruction for the circle-and-arc trajectory.

Authors:  Alexander Katsevich
Journal:  Phys Med Biol       Date:  2005-04-27       Impact factor: 3.609

8.  Extension of the reconstruction field of view and truncation correction using sinogram decomposition.

Authors:  Alexander A Zamyatin; Satoru Nakanishi
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

9.  Half-scan cone-beam x-ray microtomography formula.

Authors:  G Wang; Y Liu; T H Lin; P C Cheng
Journal:  Scanning       Date:  1994 Jul-Aug       Impact factor: 1.932

  9 in total
  3 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory.

Authors:  Stefan Hoppe; Joachim Hornegger; Frank Dennerlein; Günter Lauritsch; Frédéric Noo
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-21       Impact factor: 2.924

3.  Scout-view assisted interior micro-CT.

Authors:  Kriti Sen Sharma; Christian Holzner; Dragoş M Vasilescu; Xin Jin; Shree Narayanan; Masoud Agah; Eric A Hoffman; Hengyong Yu; Ge Wang
Journal:  Phys Med Biol       Date:  2013-06-04       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.