[Endosseous titanium implants as orthodontic anchoring elements. Experimental studies and clinical application].

H Wehrbein1.   

Abstract

Part 1 of this study, which deals with experimental use of titanium implants in animals (Brånemark, dimension 10 x 3.75 mm), examines the long-term orthodontic application of force on the quantity of peri-implant and paraimplant bone and on direct bone contact (in %) at the implant surface. In the experiment 6 premolars (P3 mandible/maxilla and P4 mandible) were extracted from each of 2 foxhounds. After 12 weeks each dog received 6 implants (P3 and P4 areas). After the implants had healed for 25 weeks, the fixtures in the P3 areas were used as anchoring elements (test implants) for P2 distalization over a period of 26 weeks (continuous force applied: approximately 2 N). The implants in the P4 area served as the control group. Histological analysis revealed in the test implants (mandible) in comparison to the control implants (mandible) the following differences: broader cortical bone; wider peri-implant bone casing; denser, partly sclerotic spongiosa (pressure side); and thicker trabecula (tension side). Fluorescence microscopy revealed that these findings were the result of distinct lamellar bone apposition during the force application phase. In comparison, far less lamellar apposition was found in the test implants (maxilla). The mean percentage of direct bone contact at the implant surface was: Control implants (mandible, n = 4): 40.5%; test implants (mandible, n = 4): 51.6%; and test implants (maxilla, n = 4): 42.4%. Part 2, the clinical portion of the study, presents the suitability and feasibility of using endosseous implants as orthodontic anchoring elements, first, for orthodontic-prosthetic anchoring, and, second, for orthodontic anchoring only. Further, the significance of these aspects in relation to the implant site, to implant dimension, and to the type of implant anchoring are recorded.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7995605     DOI: 10.1007/BF02173755

Source DB:  PubMed          Journal:  Fortschr Kieferorthop        ISSN: 0015-816X


  23 in total

1.  Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site.

Authors:  W E Roberts; K J Marshall; P G Mozsary
Journal:  Angle Orthod       Date:  1990       Impact factor: 2.079

2.  Aspects on osseointegrated implants inserted in growing jaws. A biometric and radiographic study in the young pig.

Authors:  B Thilander; J Odman; K Gröndahl; U Lekholm
Journal:  Eur J Orthod       Date:  1992-04       Impact factor: 3.075

3.  The orthodontic movement of a metal implant.

Authors:  S W Wigglesworth
Journal:  Br J Orthod       Date:  1977-10

4.  Osseointegrated titanium implants--a new approach in orthodontic treatment.

Authors:  J Odman; U Lekholm; T Jemt; P I Brånemark; B Thilander
Journal:  Eur J Orthod       Date:  1988-05       Impact factor: 3.075

Review 5.  Osseointegration and its experimental background.

Authors:  P I Brånemark
Journal:  J Prosthet Dent       Date:  1983-09       Impact factor: 3.426

6.  The possibility of skeletal anchorage.

Authors:  T D Creekmore; M K Eklund
Journal:  J Clin Orthod       Date:  1983-04

7.  Studies on the efficacy of implants as orthodontic anchorage.

Authors:  J B Gray; M E Steen; G J King; A E Clark
Journal:  Am J Orthod       Date:  1983-04

Review 8.  Uses of implants in orthodontics.

Authors:  P A Shapiro; V G Kokich
Journal:  Dent Clin North Am       Date:  1988-07

9.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981

10.  Tissue reactions towards titanium implants inserted in growing jaws. A histological study in the pig.

Authors:  L Sennerby; J Odman; U Lekholm; B Thilander
Journal:  Clin Oral Implants Res       Date:  1993-06       Impact factor: 5.977

View more
  4 in total

1.  Osteodynamics around orthodontically loaded short maxillary implants. An experimental pilot study.

Authors:  H Wehrbein; M Yildirim; P Diedrich
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

2.  The Orthosystem--a new implant system for orthodontic anchorage in the palate.

Authors:  H Wehrbein; J Glatzmaier; U Mundwiller; P Diedrich
Journal:  J Orofac Orthop       Date:  1996-06       Impact factor: 1.938

3.  [The development of a resorbable implant system for orthodontic anchorage. The BIOS implant system. Bioresorbable implant anchor for orthodontic systems].

Authors:  J Glatzmaier; H Wehrbein; P Diedrich
Journal:  Fortschr Kieferorthop       Date:  1995-05

4.  A piezo surgery with corticotomies and implant placement as part of a multidisciplinary approach to treat malocclusion disorder in an adult patient: clinical report.

Authors:  Federico Gelpi; Daniele De Santis; Simone Marconcini; Francesco Briguglio; Marco Finotti
Journal:  Int J Implant Dent       Date:  2015-08-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.