Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems.

M J Flynn1, E Samei.   

Abstract

The purpose of this study was to compare the image quality for a digital storage phosphor system using 1760 x 2140 (2k) and 3520 x 4280 (4k) image arrays. Measurements were made on a chest radiography system (Fuji FCR-9501) with special provisions to be operated in both 2k (standard) and 4k (HQ) modes. Presampled modulation transfer functions (MTF) were measured using an edge method. Noise power spectra (NPS) were determined for different input exposures by two-dimensional Fourier analysis. These measures along with exposure measurements and an x-ray spectral model were used to determine the frequency-dependent detective quantum efficiency DQE (f) of the system for the 4k and the 2k modes. The magnitude of the NPS for the 4k mode was about 1/2 that of the 2k mode. A MTF value of 0.5 was found at 1.25 cycles/mm for the 4k system and 1.50 cycles/mm for the 2k system. The 4k images had an extended MTF of 0.1 at 4.5 cycles/mm in the plate-scan direction. Overall, the DQE (f) of the 4k mode was slightly better than that for the 2k mode by about 0.02 due primarily to its better noise characteristics.

Entities:  

Mesh:

Year:  1999        PMID: 10501062     DOI: 10.1118/1.598656

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

2.  Solid-state fluoroscopic imager for high-resolution angiography: physical characteristics of an 8 cm x 8 cm experimental prototype.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan; Steven K Onishi
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

3.  An ROC study of chest radiographs: 2K Versus 4K high-resolution soft-copy images.

Authors:  Su Young Kim; Yoon Joon Hwang; Yoon Hee Han; Jung Wook Seo; Ji Young Lee; Yong Hoon Kim; Soon Joo Cha; Gham Hur; Sung Soon Lee
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

4.  Assessment of detective quantum efficiency: intercomparison of a recently introduced international standard with prior methods.

Authors:  Nicole T Ranger; Ehsan Samei; James T Dobbins; Carl E Ravin
Journal:  Radiology       Date:  2007-06       Impact factor: 11.105

5.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

6.  Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.

Authors:  Claus Koelblinger; Mathias Prokop; Michael Weber; Johannes Sailer; Fabiola Cartes-Zumelzu; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2007-05-10       Impact factor: 5.315

7.  Validation of CT dose-reduction simulation.

Authors:  Parinaz Massoumzadeh; Steven Don; Charles F Hildebolt; Kyongtae T Bae; Bruce R Whiting
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

8.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

9.  Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology.

Authors:  Ehsan Samei; Nicole T Ranger; Alistair MacKenzie; Ian D Honey; James T Dobbins; Carl E Ravin
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

10.  On the performance of the noise power spectrum from the gain-corrected radiography images.

Authors:  Dong Sik Kim; Eunae Lee
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.