Literature DB >> 10048849

Filter-based coded-excitation system for high-speed ultrasonic imaging.

J Shen1, E S Ebbini.   

Abstract

We have recently presented a new algorithm for high-speed parallel processing of ultrasound pulse-echo data for real-time three-dimensional (3-D) imaging. The approach utilizes a discretized linear model of the echo data received from the region of interest (ROI) using a conventional beam former. The transmitter array elements are fed with binary codes designed to produce distinct impulse responses from different directions in ROI. Image reconstruction in ROI is achieved with a regularized pseudoinverse operator derived from the linear receive signal model. The reconstruction operator can be implemented using a transversal filter bank with every filter in the bank designed to extract echoes from a specific direction in the ROI. The number of filters in the bank determines the number of image lines acquired simultaneously. In this paper, we present images of a cyst phantom reconstructed based on our formulation. A number of issues of practical significance in image reconstruction are addressed. Specifically, an augmented model is introduced to account for imperfect blocking of echoes from outside the ROI. We have also introduced a column-weighting algorithm for minimizing the number of filter coefficients. In addition, a detailed illustration of a full image reconstruction using subimage acquisition and compounding is given. Experimental results have shown that the new approach is valid for phased-array pulse-echo imaging of speckle-generating phantoms typically used in characterizing medical imaging systems. Such coded-excitation-based image reconstruction from speckle-generating phantoms, to the best of our knowledge, have not been reported previously.

Mesh:

Year:  1998        PMID: 10048849      PMCID: PMC2844505          DOI: 10.1109/42.746625

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

Review 1.  Dynamic three-dimensional echocardiography: methods and clinical potential.

Authors:  N G Pandian; J Roelandt; N C Nanda; L Sugeng; Q L Cao; J Azevedo; S L Schwartz; M A Vannan; A Ludomirski; G Marx
Journal:  Echocardiography       Date:  1994-05       Impact factor: 1.724

2.  Precordial three-dimensional echocardiography with a rotational imaging probe: methods and initial clinical experience.

Authors:  J Roelandt; A Salustri; B Mumm; W Vletter
Journal:  Echocardiography       Date:  1995-05       Impact factor: 1.724

3.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering.

Authors:  S W Smith; H R Pavy; O T von Ramm
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

4.  Beam steering with pulsed two-dimensional transducer arrays.

Authors:  D H Turnbull; F S Foster
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

5.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display.

Authors:  O T von Ramm; S W Smith; H R Pavy
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

6.  Ultrasonic echo imaging with pseudo-random and pulsed sources: a comparative study.

Authors:  D Nahamoo; A C Kak
Journal:  Ultrason Imaging       Date:  1981-01       Impact factor: 1.578

7.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays.

Authors:  D P Shattuck; M D Weinshenker; S W Smith; O T von Ramm
Journal:  J Acoust Soc Am       Date:  1984-04       Impact factor: 1.840

8.  Signal, noise, and contrast in nuclear magnetic resonance (NMR) imaging.

Authors:  W A Edelstein; P A Bottomley; H R Hart; L S Smith
Journal:  J Comput Assist Tomogr       Date:  1983-06       Impact factor: 1.826

  8 in total
  5 in total

1.  Coded pulse excitation for ultrasonic strain imaging.

Authors:  Jie Liu; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

2.  Imaging with concave large-aperture therapeutic ultrasound arrays using conventional synthetic-aperture beamforming.

Authors:  Yayun Wan; Emad S Ebbini
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-08       Impact factor: 2.725

3.  Adaptive transthoracic refocusing of dual-mode ultrasound arrays.

Authors:  John R Ballard; Andrew J Casper; Yayun Wan; Emad S Ebbini
Journal:  IEEE Trans Biomed Eng       Date:  2009-07-31       Impact factor: 4.538

4.  A post-beamforming 2-D pseudoinverse filter for coarsely sampled ultrasound arrays.

Authors:  Yayun Wan; Emad S Ebbini
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-09       Impact factor: 2.725

5.  A New Method for Pseudo-increasing Frame Rates of Echocardiography Images Using Manifold Learning.

Authors:  Parisa Gifani; Hamid Behnam; Zahra Alizadeh Sani
Journal:  J Med Signals Sens       Date:  2011-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.