Literature DB >> 18267563

High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering.

S W Smith1, H R Pavy, O T von Ramm.   

Abstract

Transducer design and phased array beam steering are developed for a volumetric ultrasound scanner that enables the 3-D visualization of dynamic structures in real time. The authors describe the design considerations and preliminary evaluation of a high-speed, online volumetric ultrasound imaging system that uses the principles of pulse-echo, phased array scanning with a 2-D array transducer. Several 2-D array designs are analyzed for resolution and main lobe-side lobe ratio by simulation using 2-D fast Fourier transform methods. Fabrication techniques are described for 2-D array transducer. Experimental measurements of pulse-echo point spread responses for 2-D arrays agree with the simulations. Measurements of pulse-echo sensitivity, bandwidth, and crosstalk are included.

Year:  1991        PMID: 18267563     DOI: 10.1109/58.68466

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  37 in total

1.  Volumetric Hall effect tomography--a feasibility study.

Authors:  H Wen
Journal:  Ultrason Imaging       Date:  1999-07       Impact factor: 1.578

Review 2.  Real-time three-dimensional echocardiography: an overview.

Authors:  J A Panza
Journal:  Int J Cardiovasc Imaging       Date:  2001-06       Impact factor: 2.357

3.  New fabrication techniques for ring-array transducers for real-time 3D intravascular ultrasound.

Authors:  Edward D Light; Victor Lieu; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2009-10       Impact factor: 1.578

4.  Filter-based coded-excitation system for high-speed ultrasonic imaging.

Authors:  J Shen; E S Ebbini
Journal:  IEEE Trans Med Imaging       Date:  1998-12       Impact factor: 10.048

5.  Real-time 3-d intracranial ultrasound with an endoscopic matrix array transducer.

Authors:  Edward D Light; Srinivasan Mukundan; Patrick D Wolf; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2007-05-03       Impact factor: 2.998

6.  Fabrication and evaluation of fully-sampled, two-dimensional transducer array for "Sonic Window" imaging system.

Authors:  Matthew D C Eames; John A Hossack
Journal:  Ultrasonics       Date:  2008-03-05       Impact factor: 2.890

7.  Vibrating interventional device detection using real-time 3-D color Doppler.

Authors:  Matthew P Fronheiser; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

8.  Real-time 3-D contrast-enhanced transcranial ultrasound and aberration correction.

Authors:  Nikolas M Ivancevich; Gianmarco F Pinton; Heather A Nicoletto; Ellen Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2008-04-18       Impact factor: 2.998

9.  Three-dimensional ultrasound guidance of autonomous robotic breast biopsy: feasibility study.

Authors:  Kaicheng Liang; Albert J Rogers; Edward D Light; Daniel von Allmen; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2010-01       Impact factor: 2.998

10.  Real-time 3-D ultrasound guidance of interventional devices.

Authors:  Edward D Light; John F Angle; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.