Literature DB >> 15801311

Coded pulse excitation for ultrasonic strain imaging.

Jie Liu1, Michael F Insana.   

Abstract

Decorrelation strain noise can be significantly reduced in low echo-signal-to-noise (eSNR) conditions using coded excitation. Large time-bandwidth-product (>30) pulses are transmitted into tissue mimicking phantoms with 2.5-mm diameter inclusions that mimic the elastic properties of breast lesions. We observed a 5-10 dB improvement in eSNR that led to a doubling of the depth of focus for strain images with no reduction of spatial resolution. In high eSNR conditions, coded excitation permits the use of higher carrier frequencies and shorter correlation windows to improve the attainable spatial resolution for strain relative to that obtained with conventional short pulses. This paper summarizes comparative studies of strain imaging in noise-limited conditions obtained by short pulses and four common aperiodic codes (chirp, Barker, suboptimal, and Golay) as a function of attenuation, eSNR and applied strain. Imaging performance is quantified using SNR for displacement (SNRd), local modulation transfer function (LMTF), and contrast-to-noise ratio for strain (CNRepsilon). We found that chirp and Golay codes are the most robust for imaging soft tissue deformation using matched filter decoding. Their superior performance is obtained by balancing the need for low-range lobes, large eSNR improvement, and short-code duration.

Entities:  

Mesh:

Year:  2005        PMID: 15801311      PMCID: PMC2771932          DOI: 10.1109/tuffc.2005.1406549

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  16 in total

1.  Space-time encoding for high frame rate ultrasound imaging.

Authors:  Thanassis X Misaridis; Jørgen A Jensen
Journal:  Ultrasonics       Date:  2002-05       Impact factor: 2.890

2.  Lateral resolution in elastography.

Authors:  Raffaella Righetti; Seshadri Srinivasan; Jonathan Ophir
Journal:  Ultrasound Med Biol       Date:  2003-05       Impact factor: 2.998

3.  Linear system models for ultrasonic imaging: application to signal statistics.

Authors:  Roger J Zemp; Craig K Abbey; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-06       Impact factor: 2.725

4.  Estimation of ultrasonic attenuation in a bone using coded excitation.

Authors:  A Nowicki; J Litniewski; W Secomski; P A Lewin; I Trots
Journal:  Ultrasonics       Date:  2003-11       Impact factor: 2.890

5.  Pulse elongation and deconvolution filtering for medical ultrasonic imaging.

Authors:  B Haider; P A Lewin; K E Thomenius
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

6.  2-D companding for noise reduction in strain imaging.

Authors:  P Chaturvedi; M F Insana; T J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

7.  Testing the limitations of 2-D companding for strain imaging using phantoms.

Authors:  P Chaturvedi; M F Insana; T J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

8.  Coded excitation system for improving the penetration of real-time phased-array imaging systems.

Authors:  M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

9.  Performance optimization in elastography: multicompression with temporal stretching.

Authors:  T Varghese; J Ophir
Journal:  Ultrason Imaging       Date:  1996-07       Impact factor: 1.578

10.  Frequency-dependent attenuation in breast tissue characterization.

Authors:  L Landini; R Sarnelli; F Squartini
Journal:  Ultrasound Med Biol       Date:  1985 Jul-Aug       Impact factor: 2.998

View more
  8 in total

1.  Modeling and phantom studies of ultrasonic wall shear rate measurements using coded pulse excitation.

Authors:  Jean K Tsou; Jie Liu; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-04       Impact factor: 2.725

2.  SNR comparisons of beamforming strategies.

Authors:  Jie Liu; Kang-Sik Kim; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-05       Impact factor: 2.725

3.  Coded Spectral Doppler Imaging: From Simulation to Real-Time Processing.

Authors:  Alessandro Ramalli; Enrico Boni; Alessandro Dallai; Francesco Guidi; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-26       Impact factor: 2.725

4.  Coded excitation plane wave imaging for shear wave motion detection.

Authors:  Pengfei Song; Matthew W Urban; Armando Manduca; James F Greenleaf; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-07       Impact factor: 2.725

5.  Role of ultrasonic shear rate estimation errors in assessing inflammatory response and vascular risk.

Authors:  Jean K Tsou; Jie Liu; Abdul I Barakat; Michael F Insana
Journal:  Ultrasound Med Biol       Date:  2008-01-22       Impact factor: 2.998

6.  Improved scatterer size estimation using backscatter coefficient measurements with coded excitation and pulse compression.

Authors:  Steven G Kanzler; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2008-06       Impact factor: 2.482

7.  Ultrasound Elasticity Imaging System with Chirp-Coded Excitation for Assessing Biomechanical Properties of Elasticity Phantom.

Authors:  Guan-Chun Chun; Hsing-Jung Chiang; Kuan-Hung Lin; Chien-Ming Li; Pei-Jarn Chen; Tainsong Chen
Journal:  Materials (Basel)       Date:  2015-12-03       Impact factor: 3.623

8.  Improved shear wave motion detection using coded excitation for transient elastography.

Authors:  Xiao-Nian He; Xian-Fen Diao; Hao-Ming Lin; Xin-Yu Zhang; Yuan-Yuan Shen; Si-Ping Chen; Zheng-Di Qin; Xin Chen
Journal:  Sci Rep       Date:  2017-03-15       Impact factor: 4.379

  8 in total