Imaging with concave large-aperture therapeutic ultrasound arrays using conventional synthetic-aperture beamforming.

Yayun Wan1, Emad S Ebbini.   

Abstract

Several dual-mode ultrasound array (DMUA) systems are being investigated for potential use in image- guided surgery. In therapeutic mode, DMUAs generate pulsed or continuous-wave (CW) high-intensity focused ultrasound (HIFU) beams capable of generating localized therapeutic effects within the focal volume. In imaging mode, pulse-echo data can be collected from the DMUA elements to obtain B-mode images or other forms of feedback on the state of the target tissue before, during, and after the application of the therapeutic HIFU beam. Therapeutic and technological constraints give rise to special characteristics of therapeutic arrays. Specifically, DMUAs have concave apertures with low f-number values and are typically coarsely sampled using directive elements. These characteristics necessitate pre- and post-beamforming signal processing of echo data to improve the spatial and contrast resolution and maximize the image uniformity within the imaging field of view (IxFOV). We have recently developed and experimentally validated beamforming algorithms for concave large-aperture DMUAs with directive elements. Experimental validation was performed using a 1 MHz, 64-element, concave spherical aperture with 100 mm radius of curvature. The aperture was sampled in the lateral direction using elongated elements 1-lambda x 33.3-lambda with 1.333-lambda center-to-center spacing (lambda is the wavelength). This resulted in f-number values of 0.8 and 2 in the azimuth and elevation directions, respectively. In this paper, we present a new DMUA design approach based on different sampling of the shared concave aperture to improve image quality while maintaining therapeutic performance. A pulse-wave (PW) simulation model using a modified version of the Field II program is used in this study. The model is used in generating pulse-echo data for synthetic-aperture (SA) beamforming for forming images of a variety of targets, e.g., wire arrays and speckle-generating cyst phantoms. To provide validation for the simulation model and illustrate the improvements in image quality, we show SA images of similar targets using pulse-echo data acquired experimentally using our existing 64-element prototype. The PW simulation model is used to investigate the effect of transducer bandwidth as well as finer sampling of the concave DMUA aperture on the image quality. The results show that modest increases in the sampling density and transducer bandwidth result in significant improvement in spatial and contrast resolutions in addition to extending the DMUA IxFOV.

Entities:  

Mesh:

Year:  2008        PMID: 18986915      PMCID: PMC2692604          DOI: 10.1109/TUFFC.2008.856

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  15 in total

1.  New piezoelectric transducers for therapeutic ultrasound.

Authors:  J Y Chapelon; D Cathignol; C Cain; E Ebbini; J U Kluiwstra; O A Sapozhnikov; G Fleury; R Berriet; L Chupin; J L Guey
Journal:  Ultrasound Med Biol       Date:  2000-01       Impact factor: 2.998

2.  MR imaging-guided focused ultrasound surgery of uterine leiomyomas: a feasibility study.

Authors:  Clare M C Tempany; Elizabeth A Stewart; Nathan McDannold; Bradley J Quade; Ferenc A Jolesz; Kullervo Hynynen
Journal:  Radiology       Date:  2003-03       Impact factor: 11.105

3.  In-vivo non-invasive motion tracking and correction in high intensity focused ultrasound therapy.

Authors:  Fabrice Marquet; Mathieu Pernot; Jean-Francois Aubry; Mickael Tanter; Gabriel Montaldo; Mathias Fink
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

4.  Two-step hybrid virtual array ray (VAR) technique for focusing through the rib cage.

Authors:  Y Y Botros; E S Ebbini; J L Volakis
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

5.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

6.  Trans-skull ultrasound therapy: the feasibility of using image-derived skull thickness information to correct the phase distortion.

Authors:  K Hynynen; J Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

7.  Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound.

Authors:  R Seip; E S Ebbini
Journal:  IEEE Trans Biomed Eng       Date:  1995-08       Impact factor: 4.538

8.  1.5-D high intensity focused ultrasound array for non-invasive prostate cancer surgery.

Authors:  L Curiel; F Chavrier; R Souchon; A Birer; J Y Chapelon
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-02       Impact factor: 2.725

9.  Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle.

Authors:  J De Poorter; C De Wagter; Y De Deene; C Thomsen; F Ståhlberg; E Achten
Journal:  Magn Reson Med       Date:  1995-01       Impact factor: 4.668

10.  Noninvasive thermometry with a clinical x-ray CT scanner.

Authors:  B G Fallone; P R Moran; E B Podgorsak
Journal:  Med Phys       Date:  1982 Sep-Oct       Impact factor: 4.071

View more
  6 in total

1.  Reversible neuroinhibition by focused ultrasound is mediated by a thermal mechanism.

Authors:  David P Darrow; Parker O'Brien; Thomas J Richner; Theoden I Netoff; Emad S Ebbini
Journal:  Brain Stimul       Date:  2019-07-23       Impact factor: 8.955

2.  Real-time implementation of a dual-mode ultrasound array system: in vivo results.

Authors:  Andrew J Casper; Dalong Liu; John R Ballard; Emad S Ebbini
Journal:  IEEE Trans Biomed Eng       Date:  2013-05-21       Impact factor: 4.538

3.  Adaptive transthoracic refocusing of dual-mode ultrasound arrays.

Authors:  John R Ballard; Andrew J Casper; Yayun Wan; Emad S Ebbini
Journal:  IEEE Trans Biomed Eng       Date:  2009-07-31       Impact factor: 4.538

4.  Ultrasound transducer and system for real-time simultaneous therapy and diagnosis for noninvasive surgery of prostate tissue.

Authors:  Jong Seob Jeong; Jin Ho Chang; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-09       Impact factor: 2.725

5.  In Vivo application and localization of transcranial focused ultrasound using dual-mode ultrasound arrays.

Authors:  Alyona Haritonova; Dalong Liu; Emad S Ebbini
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-12       Impact factor: 2.725

6.  Highly Integrated Multiplexing and Buffering Electronics for Large Aperture Ultrasonic Arrays.

Authors:  Robert Wodnicki; Haochen Kang; Di Li; Douglas N Stephens; Hayong Jung; Yizhe Sun; Ruimin Chen; Lai-Ming Jiang; Nestor E Cabrera-Munoz; Josquin Foiret; Qifa Zhou; Katherine W Ferrara
Journal:  BME Front       Date:  2022-06-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.