Literature DB >> 9797151

Adiabatic water suppression using frequency selective excitation.

R A de Graaf1, K Nicolay.   

Abstract

A new method for B1-insensitive water suppression using adiabatic RF pulses is described. The transition zone of the inversion profile of adiabatic full passage (AFP) pulses is used for frequency-selective excitation followed by dephasing of the excited water with magnetic field gradients. Several improvements of AFP pulses, which also have implications for other applications, are described. The technique was evaluated by simulations based on the Bloch equations (including relaxation), in vitro experiments and an in vivo verification on neonatal and adult rat brain.

Entities:  

Mesh:

Year:  1998        PMID: 9797151     DOI: 10.1002/mrm.1910400508

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Regional glucose metabolism and glutamatergic neurotransmission in rat brain in vivo.

Authors:  Robin A de Graaf; Graeme F Mason; Anant B Patel; Douglas L Rothman; Kevin L Behar
Journal:  Proc Natl Acad Sci U S A       Date:  2004-08-13       Impact factor: 11.205

2.  Effects of γ-Aminobutyric acid transporter 1 inhibition by tiagabine on brain glutamate and γ-Aminobutyric acid metabolism in the anesthetized rat In vivo.

Authors:  Anant B Patel; Robin A de Graaf; Douglas L Rothman; Kevin L Behar
Journal:  J Neurosci Res       Date:  2015-02-06       Impact factor: 4.164

3.  High resolution NMR spectroscopy of rat brain in vivo through indirect zero-quantum-coherence detection.

Authors:  Robin A de Graaf; Douglas L Rothman; Kevin L Behar
Journal:  J Magn Reson       Date:  2007-06-10       Impact factor: 2.229

4.  Compensation of gradient-induced magnetic field perturbations.

Authors:  Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2008-02-23       Impact factor: 2.229

5.  Compartmentalized low-rank recovery for high-resolution lipid unsuppressed MRSI.

Authors:  Ipshita Bhattacharya; Mathews Jacob
Journal:  Magn Reson Med       Date:  2016-11-11       Impact factor: 4.668

6.  Water removal in MR spectroscopic imaging with L2 regularization.

Authors:  Liangjie Lin; Michal Považan; Adam Berrington; Zhong Chen; Peter B Barker
Journal:  Magn Reson Med       Date:  2019-05-31       Impact factor: 4.668

7.  Water suppression in the human brain with hypergeometric RF pulses for single-voxel and multi-voxel MR spectroscopy.

Authors:  Kimberly L Chan; Ronald Ouwerkerk; Peter B Barker
Journal:  Magn Reson Med       Date:  2018-02-14       Impact factor: 4.668

8.  Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

Authors:  Chao Ma; Fan Lam; Curtis L Johnson; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

9.  Two-dimensional J-resolved LASER and semi-LASER spectroscopy of human brain.

Authors:  Meijin Lin; Anand Kumar; Shaolin Yang
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recovery.

Authors:  Priti Balchandani; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.