Literature DB >> 25762370

Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

Chao Ma1, Fan Lam1,2, Curtis L Johnson1, Zhi-Pei Liang1,2.   

Abstract

PURPOSE: To remove nuisance signals (e.g., water and lipid signals) for (1) H MRSI data collected from the brain with limited and/or sparse (k, t)-space coverage.
METHODS: A union-of-subspace model is proposed for removing nuisance signals. The model exploits the partial separability of both the nuisance signals and the metabolite signal, and decomposes an MRSI dataset into several sets of generalized voxels that share the same spectral distributions. This model enables the estimation of the nuisance signals from an MRSI dataset that has limited and/or sparse (k, t)-space coverage.
RESULTS: The proposed method has been evaluated using in vivo MRSI data. For conventional chemical shift imaging data with limited k-space coverage, the proposed method produced "lipid-free" spectra without lipid suppression during data acquisition at 130 ms echo time. For sparse (k, t)-space data acquired with conventional pulses for water and lipid suppression, the proposed method was also able to remove the remaining water and lipid signals with negligible residuals.
CONCLUSION: Nuisance signals in (1) H MRSI data reside in low-dimensional subspaces. This property can be utilized for estimation and removal of nuisance signals from (1) H MRSI data even when they have limited and/or sparse coverage of (k, t)-space. The proposed method should prove useful especially for accelerated high-resolution (1) H MRSI of the brain.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  1H spectroscopic imaging; chemical shift imaging; lipid removal; partial separability; sparse sampling; union of subspaces; water removal

Mesh:

Year:  2015        PMID: 25762370      PMCID: PMC4567537          DOI: 10.1002/mrm.25635

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  34 in total

1.  A hybrid technique for spectroscopic imaging with reduced truncation artifact.

Authors:  G Metzger; S Sarkar; X Zhang; K Heberlein; M Patel; X Hu
Journal:  Magn Reson Imaging       Date:  1999-04       Impact factor: 2.546

2.  BISTRO: an outer-volume suppression method that tolerates RF field inhomogeneity.

Authors:  Y Luo; R A de Graaf; L DelaBarre; A Tannús; M Garwood
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

3.  Truncation artifact reduction in spectroscopic imaging using a dual-density spiral k-space trajectory.

Authors:  Shantanu Sarkar; Keith Heberlein; Xiaoping Hu
Journal:  Magn Reson Imaging       Date:  2002-12       Impact factor: 2.546

4.  Optimal phased-array combination for spectroscopy.

Authors:  Mark Bydder; Gavin Hamilton; Takeshi Yokoo; Claude B Sirlin
Journal:  Magn Reson Imaging       Date:  2008-05-16       Impact factor: 2.546

5.  Anatomically constrained reconstruction from noisy data.

Authors:  Justin P Haldar; Diego Hernando; Sheng-Kwei Song; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

6.  Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging.

Authors:  P Le Roux; R J Gilles; G C McKinnon; P G Carlier
Journal:  J Magn Reson Imaging       Date:  1998 Sep-Oct       Impact factor: 4.813

7.  1H NMR chemical shift selective (CHESS) imaging.

Authors:  A Haase; J Frahm; W Hänicke; D Matthaei
Journal:  Phys Med Biol       Date:  1985-04       Impact factor: 3.609

8.  Denoising MR spectroscopic imaging data with low-rank approximations.

Authors:  Hien M Nguyen; Xi Peng; Minh N Do; Zhi-Pei Liang
Journal:  IEEE Trans Biomed Eng       Date:  2012-10-09       Impact factor: 4.538

9.  A subspace approach to high-resolution spectroscopic imaging.

Authors:  Fan Lam; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2014-02-04       Impact factor: 4.668

10.  Multisection proton MR spectroscopic imaging of the brain.

Authors:  J H Duyn; J Gillen; G Sobering; P C van Zijl; C T Moonen
Journal:  Radiology       Date:  1993-07       Impact factor: 11.105

View more
  25 in total

Review 1.  Imaging based magnetic resonance spectroscopy (MRS) localization for quantitative neurochemical analysis and cerebral metabolism studies.

Authors:  Phil Lee; Peter Adany; In-Young Choi
Journal:  Anal Biochem       Date:  2017-01-10       Impact factor: 3.365

2.  Speeding up dynamic spiral chemical shift imaging with incoherent sampling and low-rank matrix completion.

Authors:  Stephen J DeVience; Dirk Mayer
Journal:  Magn Reson Med       Date:  2016-02-24       Impact factor: 4.668

3.  Simultaneous metabolic and functional imaging of the brain using SPICE.

Authors:  Rong Guo; Yibo Zhao; Yudu Li; Yao Li; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2019-07-11       Impact factor: 4.668

4.  A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities.

Authors:  Paul Kyu Han; Chao Ma; Kexin Deng; Shuang Hu; Kyung-Wook Jee; Kui Ying; Yen-Lin Chen; Georges El Fakhri
Journal:  Magn Reson Imaging       Date:  2017-09-14       Impact factor: 2.546

5.  Ultrafast magnetic resonance spectroscopic imaging using SPICE with learned subspaces.

Authors:  Fan Lam; Yudu Li; Rong Guo; Bryan Clifford; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

6.  Spectral Quantification for High-Resolution MR Spectroscopic Imaging With Spatiospectral Constraints.

Authors:  Qiang Ning; Chao Ma; Fan Lam; Zhi-Pei Liang
Journal:  IEEE Trans Biomed Eng       Date:  2016-07-27       Impact factor: 4.538

7.  Compartmentalized low-rank recovery for high-resolution lipid unsuppressed MRSI.

Authors:  Ipshita Bhattacharya; Mathews Jacob
Journal:  Magn Reson Med       Date:  2016-11-11       Impact factor: 4.668

8.  A Subspace Approach to Spectral Quantification for MR Spectroscopic Imaging.

Authors:  Yudu Li; Fan Lam; Bryan Clifford; Zhi-Pei Liang
Journal:  IEEE Trans Biomed Eng       Date:  2017-08-18       Impact factor: 4.538

9.  Water removal in MR spectroscopic imaging with L2 regularization.

Authors:  Liangjie Lin; Michal Považan; Adam Berrington; Zhong Chen; Peter B Barker
Journal:  Magn Reson Med       Date:  2019-05-31       Impact factor: 4.668

10.  COMPARTMENTALIZED LOW-RANK REGULARIZATION WITH ORTHOGONALITY CONSTRAINTS FOR HIGH-RESOLUTION MRSI.

Authors:  Ipshita Bhattacharya; Mathews Jacob
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2016-06-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.