Literature DB >> 9715156

Accuracy and reliability of transanal ultrasound for anterior anal sphincter injury.

S M Sentovich1, W D Wong, G J Blatchford.   

Abstract

INTRODUCTION: Although transanal ultrasound has rapidly become the test of choice for the diagnosis of anal sphincter injury, the accuracy and reliability of this technique are unknown. This study evaluates the accuracy and reliability of transanal ultrasound for anterior (obstetric-related) anal sphincter injury.
METHODS: Sixty-two women underwent transanal ultrasound with hard-copy images obtained at 0.5-cm intervals from the anal verge to 2.5 cm into the anal canal. All transanal ultrasound procedures were also recorded on videotape. Two experienced ultrasonographers blinded as to the patients' clinical history and examination independently reviewed the images and videotape recordings for the presence or absence of anal sphincter injury.
RESULTS: The accuracy of transanal ultrasound in 22 incontinent women with known anal sphincter injury was 100 percent. The accuracy of transanal ultrasound in 20 nulliparous women with intact anal sphincters was only 35 percent but improved to 50 percent after the "real time" videotape was reviewed (P = 0.16) and further improved to 85 percent when interpretation was limited to the distal 1.5 cm of the anal canal (P = 0.004). In these nulliparous women, intact internal sphincters were more accurately predicted than intact external sphincters (95 vs. 85 percent; P = 0.24). Measurement agreement between the two ultrasonographers was 68 percent (fair; kappa, 0.26) but significantly improved to 78 percent (moderate; kappa, 0.48; P = 0.0001) when interpretation was limited to the distal 1.5 cm of the anal canal. Overall clinical agreement (final scan interpretation) was good (81 percent agreement; kappa, 0.61). Agreement was better for the internal sphincter (74 percent; fair; kappa, 0.36) than the external sphincter (61 percent; poor; kappa, 0.17; P = 0.0002).
CONCLUSIONS: Although transanal ultrasound can accurately identify anterior anal sphincter injury when present, transanal ultrasound falsely identifies sphincter injury in at least 5 to 25 percent of normal anal sphincters. Only fair agreement in the interpretation of transanal ultrasound exists between experienced ultrasonographers. Both the accuracy and reliability of transanal ultrasound are significantly improved by limiting transanal ultrasound to the distal 1.5 cm of the anal canal.

Entities:  

Mesh:

Year:  1998        PMID: 9715156     DOI: 10.1007/bf02237390

Source DB:  PubMed          Journal:  Dis Colon Rectum        ISSN: 0012-3706            Impact factor:   4.585


  8 in total

Review 1.  Fecal incontinence: an up-to-date critical overview of surgical treatment options.

Authors:  Christophe Müller; Orlin Belyaev; Thomas Deska; Ansgar Chromik; Dirk Weyhe; Waldemar Uhl
Journal:  Langenbecks Arch Surg       Date:  2005-08-12       Impact factor: 3.445

2.  Translabial ultrasound assessment of the anal sphincter complex: normal measurements of the internal and external anal sphincters at the proximal, mid-, and distal levels.

Authors:  Rebecca J Hall; Rebecca G Rogers; Lori Saiz; C Qualls
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2007-01-13

3.  Transrectal ultrasound, manometry, and pudendal nerve terminal latency studies in the evaluation of sphincter injuries.

Authors:  Brooke Gurland; Tracy Hull
Journal:  Clin Colon Rectal Surg       Date:  2008-08

4.  An Evidence-Based Approach to the Evaluation, Diagnostic Assessment and Treatment of Fecal Incontinence in Women.

Authors:  Isuzu Meyer; Holly E Richter
Journal:  Curr Obstet Gynecol Rep       Date:  2014-09

5.  Evaluation of anal incontinence: minimal approach, maximal effectiveness.

Authors:  Harry T Papaconstantinou
Journal:  Clin Colon Rectal Surg       Date:  2005-02

6.  Transperineal three-dimensional ultrasound imaging for detection of anatomic defects in the anal sphincter complex muscles.

Authors:  Milena M Weinstein; Dolores H Pretorius; Sung-Ai Jung; Charles W Nager; Ravinder K Mittal
Journal:  Clin Gastroenterol Hepatol       Date:  2008-08-16       Impact factor: 11.382

7.  Anal physiology testing in fecal incontinence: is it of any value?

Authors:  Massarat Zutshi; Levilester Salcedo; Jeffrey Hammel; Tracy Hull
Journal:  Int J Colorectal Dis       Date:  2009-11-10       Impact factor: 2.571

8.  Anal ultrasound and endosonographic measurement of perineal body thickness: a new evaluation for fecal incontinence in females.

Authors:  M Oberwalder; K Thaler; M K Baig; A Dinnewitzer; J Efron; E G Weiss; A M Vernava; J J Nogueras; S D Wexner
Journal:  Surg Endosc       Date:  2004-03-19       Impact factor: 4.584

  8 in total