Literature DB >> 9659094

Use of pulse oximetry for blood pressure measurement after cardiac surgery.

A J Movius1, S L Bratton, G K Sorensen.   

Abstract

Blood pressure measurement using pulse oximeter waveform change was compared with an oscillometric measurement and the gold standard, intra-arterial measurement, in children after cardiac surgery. Forty six patients were enrolled and divided into groups according to weight. Simultaneous blood pressure measurements were obtained from the arterial catheter, the oscillometric device, and the pulse oximeter. Pulse oximeter measurements were obtained with a blood pressure cuff proximal to the oximeter probe. The blood pressure measurements from the pulse oximeter method correlated better with intra-arterial measurements than those from the oscillometric device (0.77-0.96 v 0.42-0.83). The absolute differences between the pulse oximeter and intra-arterial measurements were significantly smaller than between the oscillometric and intra-arterial measurements in children less than 15.0 kg. The pulse oximeter waveform change is an accurate and reliable way to measure blood pressure in children non-invasively, and is superior to the oscillometric method for small patients.

Entities:  

Mesh:

Year:  1998        PMID: 9659094      PMCID: PMC1717578          DOI: 10.1136/adc.78.5.457

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  20 in total

1.  Prediction of arterial blood pressure in the premature neonate using the oscillometric method.

Authors:  J A Wareham; L D Haugh; S B Yeager; J D Horbar
Journal:  Am J Dis Child       Date:  1987-10

2.  Arterial pressure measurement in preterm infants.

Authors:  G Briassoulis
Journal:  Crit Care Med       Date:  1986-08       Impact factor: 7.598

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Noninvasive automatic determination of mean arterial pressure.

Authors:  M Ramsey
Journal:  Med Biol Eng Comput       Date:  1979-01       Impact factor: 2.602

Review 5.  Wave reflections and the arterial pulse.

Authors:  M F O'Rourke; T Yaginuma
Journal:  Arch Intern Med       Date:  1984-02

6.  Oscillometric and intra-arterial blood pressure measurements in the neonate: a comparison of methods.

Authors:  K Lui; P E Doyle; N Buchanan
Journal:  Aust Paediatr J       Date:  1982-03

7.  Non-invasive oscillometric measurement of systolic, mean and diastolic blood pressure in infants with congenital heart defects after operation. A comparison with direct blood pressure measurements.

Authors:  V Pilossoff; J G Schöber; D Peters; K Bühlmeyer
Journal:  Eur J Pediatr       Date:  1985-11       Impact factor: 3.183

8.  An automated oscillometric technique for estimating mean arterial pressure in critically ill newborns.

Authors:  K J Kimble; R A Darnall; M Yelderman; R L Ariagno; A K Ream
Journal:  Anesthesiology       Date:  1981-05       Impact factor: 7.892

9.  Evaluation of an automatic oscillometric method and of various cuffs for the measurement of arterial pressure in the neonate.

Authors:  G Pellegrini-Caliumi; R Agostino; S Nodari; G Maffei; C Moretti; G Bucci
Journal:  Acta Paediatr Scand       Date:  1982-09

10.  Dinamap fails to detect hypotension in very low birthweight infants.

Authors:  G K Diprose; D H Evans; L N Archer; M I Levene
Journal:  Arch Dis Child       Date:  1986-08       Impact factor: 3.791

View more
  1 in total

1.  Pulse oximetry vs non-invasive blood pressure/oscillometry to record blood pressure in neonates: A prospective observational study.

Authors:  Reenu Raju; Mathai Isac
Journal:  J Family Med Prim Care       Date:  2022-06-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.