Prediction of arterial blood pressure in the premature neonate using the oscillometric method.

J A Wareham, L D Haugh, S B Yeager, J D Horbar.   

Abstract

The noninvasive oscillometric measurement of blood pressure (BP) in preterm neonates has become a common practice in intensive care nurseries. The method has gained acceptance primarily through its correlation with direct arterial measurement. In this study, the oscillometric method (using Dinamap 1846) was compared with direct intra-arterial BP monitoring in 15 preterm infants. The 95% prediction intervals for individual oscillometric measurements were wide, ranging from 17 mm Hg for the mean BP to 20 mm Hg for the systolic and diastolic BP. The oscillometric method also underestimated intra-arterial systolic and mean BP and overestimated diastolic BP. Caution must be used when oscillometrically measuring BP in premature neonates.

Entities:  

Mesh:

Year:  1987        PMID: 3630997     DOI: 10.1001/archpedi.1987.04460100086034

Source DB:  PubMed          Journal:  Am J Dis Child        ISSN: 0002-922X


  6 in total

1.  Blood pressure monitoring: automated oscillometric devices.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1991-01

2.  Accuracy of oscillometric blood pressure measurement in critically ill neonates with reference to the arterial pressure wave shape.

Authors:  M Gevers; H R van Genderingen; H N Lafeber; W W Hack
Journal:  Intensive Care Med       Date:  1996-03       Impact factor: 17.440

3.  The Dinamap 1846SX automated blood pressure recorder: comparison with the Hawksley random zero sphygmomanometer under field conditions.

Authors:  P H Whincup; N G Bruce; D G Cook; A G Shaper
Journal:  J Epidemiol Community Health       Date:  1992-04       Impact factor: 3.710

4.  Systolic blood pressure in babies of less than 32 weeks gestation in the first year of life. Northern Neonatal Nursing Initiative.

Authors: 
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-01       Impact factor: 5.747

5.  Factors influencing plasma renin and renin substrate in premature infants.

Authors:  T J Stephenson; F Broughton Pipkin; A C Elias-Jones
Journal:  Arch Dis Child       Date:  1991-10       Impact factor: 3.791

6.  Use of pulse oximetry for blood pressure measurement after cardiac surgery.

Authors:  A J Movius; S L Bratton; G K Sorensen
Journal:  Arch Dis Child       Date:  1998-05       Impact factor: 3.791