Literature DB >> 15965594

Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws.

M Cimerman1, A Cör, M Ceh, A Kristan, J Pizem, M Tonin.   

Abstract

The aim of the study was to compare the pin-bone interface microstructural characteristics of hydroxyapatite-coated (HAC) and stainless steel Schanz screws after 2, 4 and 6 months of implantation in a sheep model. The microstructure and composition of the hydroxyapatite coating were analyzed using scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. Twelve coated and 12 uncoated screws were implanted into both femora of three sheep, each sheep receiving eight screws. Specimens of polished bone with screws were examined with SEM and light microscope for morphometric analyses. The HAC was approx. 40 microm thick, the grain size ranged from 5 to 40 microm, with pores less than 20 microm. The atomic ratio of Ca/P was 1.62. SEM showed that the bone-implant contact was better with HAC than with uncoated implants. The ingrowth of the bone in the HAC was clearly seen. Morphometric analysis showed good bone-implant contact in 65.1 (+/-24.6)% in the HAC and 32.0 (+/-23.3)% in the uncoated group (p<0.001). Although the percentage of good contact increased with time for both groups, it was significantly higher for HAC screws. Our investigation demonstrated a time dependent improvement of implant-bone contact of the HAC compared to standard stainless steel implants in the chosen experimental conditions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15965594     DOI: 10.1007/s10856-005-2533-5

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  42 in total

Review 1.  Properties of calcium phosphate ceramics in relation to their in vivo behavior.

Authors:  T J Blokhuis; M F Termaat; F C den Boer; P Patka; F C Bakker; H J Haarman
Journal:  J Trauma       Date:  2000-01

2.  Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating.

Authors:  E W Morscher; A Hefti; U Aebi
Journal:  J Bone Joint Surg Br       Date:  1998-03

3.  Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases.

Authors:  P Herberts; H Malchau
Journal:  Acta Orthop Scand       Date:  2000-04

4.  The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: the effect of coating thickness.

Authors:  B C Wang; T M Lee; E Chang; C Y Yang
Journal:  J Biomed Mater Res       Date:  1993-10

5.  Early failure of hydroxyapatite-coating in total knee arthroplasty. A case report.

Authors:  K G Nilsson; S Cajander; J Kärrholm
Journal:  Acta Orthop Scand       Date:  1994-04

6.  Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem.

Authors:  A J Tonino; M Thèrin; C Doyle
Journal:  J Bone Joint Surg Br       Date:  1999-01

7.  Hydroxyapatite-coated Schanz pins in external fixators used for distraction osteogenesis : a randomized, controlled trial.

Authors:  Axel Pommer; Gert Muhr; Andreas Dávid
Journal:  J Bone Joint Surg Am       Date:  2002-07       Impact factor: 5.284

8.  Histomorphometry of hydroxyapatite coated and uncoated porous titanium bone implants.

Authors:  A Moroni; V L Caja; E L Egger; L Trinchese; E Y Chao
Journal:  Biomaterials       Date:  1994-09       Impact factor: 12.479

9.  Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Seung-Hwan Oh; Ju-Moon Kim
Journal:  J Bone Joint Surg Am       Date:  2003-09       Impact factor: 5.284

10.  Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy.

Authors:  T W Bauer; R C Geesink; R Zimmerman; J T McMahon
Journal:  J Bone Joint Surg Am       Date:  1991-12       Impact factor: 5.284

View more
  1 in total

1.  Evaluation of a novel nanocrystalline hydroxyapatite paste Ostim in comparison to Alpha-BSM - more bone ingrowth inside the implanted material with Ostim compared to Alpha BSM.

Authors:  Franz-Xaver Huber; Nicholas McArthur; Lydia Heimann; Elvira Dingeldein; Héloïse Cavey; Xavier Palazzi; Gaëlle Clermont; Jean-Pierre Boutrand
Journal:  BMC Musculoskelet Disord       Date:  2009-12-22       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.