Literature DB >> 9533143

Parametric image reconstruction using spectral analysis of PET projection data.

S R Meikle1, J C Matthews, V J Cunningham, D L Bailey, L Livieratos, T Jones, P Price.   

Abstract

Spectral analysis is a general modelling approach that enables calculation of parametric images from reconstructed tracer kinetic data independent of an assumed compartmental structure. We investigated the validity of applying spectral analysis directly to projection data motivated by the advantages that: (i) the number of reconstructions is reduced by an order of magnitude and (ii) iterative reconstruction becomes practical which may improve signal-to-noise ratio (SNR). A dynamic software phantom with typical 2-[11C]thymidine kinetics was used to compare projection-based and image-based methods and to assess bias-variance trade-offs using iterative expectation maximization (EM) reconstruction. We found that the two approaches are not exactly equivalent due to properties of the non-negative least-squares algorithm. However, the differences are small (< 5%) and mainly affect parameters related to early and late time points on the impulse response function (K1 and, to a lesser extent, VD). The optimal number of EM iteration was 15-30 with up to a two-fold improvement in SNR over filtered back projection. We conclude that projection-based spectral analysis with EM reconstruction yields accurate parametric images with high SNR and has potential application to a wide range of positron emission tomography ligands.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9533143     DOI: 10.1088/0031-9155/43/3/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

1.  4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

Authors:  D J Kadrmas; G T Gullberg
Journal:  Phys Med Biol       Date:  2001-05       Impact factor: 3.609

Review 2.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

3.  Direct 4D List Mode Parametric Reconstruction for PET with a Novel EM Algorithm.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Richard E Carson
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2008

4.  Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy.

Authors:  Jing Tang; Hiroto Kuwabara; Dean F Wong; Arman Rahmim
Journal:  Phys Med Biol       Date:  2010-07-20       Impact factor: 3.609

5.  Direct reconstruction of cardiac PET kinetic parametric images using a preconditioned conjugate gradient approach.

Authors:  Yothin Rakvongthai; Jinsong Ouyang; Bastien Guerin; Quanzheng Li; Nathaniel M Alpert; Georges El Fakhri
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

Review 6.  Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT.

Authors:  H Iida; S Eberl
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

7.  DIRECT RECONSTRUCTION OF DYNAMIC PET PARAMETRIC IMAGES USING SPARSE SPECTRAL REPRESENTATION.

Authors:  Guobao Wang; Jinyi Qi
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-08-07

8.  Parameterized level-set based pharmacokinetic fluorescence optical tomography using the regularized Gauss-Newton filter.

Authors:  Omprakash Gottam; Naren Naik; Sanjay Gambhir
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

9.  Generalized algorithms for direct reconstruction of parametric images from dynamic PET data.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048

10.  Investigation of optimization-based reconstruction with an image-total-variation constraint in PET.

Authors:  Zheng Zhang; Jinghan Ye; Buxin Chen; Amy E Perkins; Sean Rose; Emil Y Sidky; Chien-Min Kao; Dan Xia; Chi-Hua Tung; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-07-25       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.