Literature DB >> 11384070

4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

D J Kadrmas1, G T Gullberg.   

Abstract

A 4D ordered-subsets maximum a posteriori (OSMAP) algorithm for dynamic SPECT is described which uses a temporal prior that constrains each voxel's behaviour in time to conform to a compartmental model. No a priori limitations on kinetic parameters are applied; rather, the parameter estimates evolve as the algorithm iterates to a solution. The estimated parameters and time-activity curves are used within the reconstruction algorithm to model changes in the activity distribution as the camera rotates, avoiding artefacts due to inconsistencies of data between projection views. This potentially allows for fewer, longer-duration scans to be used and may have implications for noise reduction. The algorithm was evaluated qualitatively using dynamic 99mTc-teboroxime SPECT scans in two patients, and quantitatively using a series of simulated phantom experiments. The OSMAP algorithm resulted in images with better myocardial uniformity and definition, gave time-activity curves with reduced noise variations, and provided wash-in parameter estimates with better accuracy and lower statistical uncertainty than those obtained from conventional ordered-subsets expectation-maximization (OSEM) processing followed by compartmental modelling. The new algorithm effectively removed the bias in k21 estimates due to inconsistent projections for sampling schedules as slow as 60 s per timeframe, but no improvement in wash-out parameter estimates was observed in this work. The proposed dynamic OSMAP algorithm provides a flexible framework which may benefit a variety of dynamic tomographic imaging applications.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11384070      PMCID: PMC2808127          DOI: 10.1088/0031-9155/46/5/315

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  29 in total

1.  Blind estimation of compartmental model parameters.

Authors:  E V Di Bella; R Clackdoyle; G T Gullberg
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

2.  Noise properties of the EM algorithm: II. Monte Carlo simulations.

Authors:  D W Wilson; B M Tsui; H H Barrett
Journal:  Phys Med Biol       Date:  1994-05       Impact factor: 3.609

3.  Model-based estimation for dynamic cardiac studies using ECT.

Authors:  P C Chiao; W L Rogers; N H Clinthorne; J A Fessler; A O Hero
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  Convergence of EM image reconstruction algorithms with Gibbs smoothing.

Authors:  K Lange
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

5.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

6.  Myocardial clearance kinetics of technetium-99m-SQ30217: a marker of regional myocardial blood flow.

Authors:  R E Stewart; M Schwaiger; G D Hutchins; P C Chiao; K P Gallagher; N Nguyen; N A Petry; W L Rogers
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

7.  Kinetic data analysis with a noisy input function.

Authors:  R H Huesman; B M Mazoyer
Journal:  Phys Med Biol       Date:  1987-12       Impact factor: 3.609

8.  Rapid back to back adenosine stress/rest technetium-99m teboroxime myocardial perfusion SPECT using a triple-detector camera.

Authors:  T Chua; H Kiat; G Germano; K Takemoto; G Fernandez; Y Biasio; J Friedman; D Berman
Journal:  J Nucl Med       Date:  1993-09       Impact factor: 10.057

9.  Effect of differential tracer washout during SPECT acquisition.

Authors:  J M Links; T L Frank; L C Becker
Journal:  J Nucl Med       Date:  1991-12       Impact factor: 10.057

Review 10.  A review of cardiac imaging with sestamibi and teboroxime.

Authors:  J A Leppo; E G DePuey; L L Johnson
Journal:  J Nucl Med       Date:  1991-10       Impact factor: 10.057

View more
  6 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

2.  A robust state-space kinetics-guided framework for dynamic PET image reconstruction.

Authors:  S Tong; A M Alessio; P E Kinahan; H Liu; P Shi
Journal:  Phys Med Biol       Date:  2011-03-25       Impact factor: 3.609

3.  Comparison of sparse domain approaches for 4D SPECT dynamic image reconstruction.

Authors:  Debasis Mitra; Mahmoud Abdalah; Rostyslav Boutchko; Haoran Chang; Uttam Shrestha; Elias Botvinick; Youngho Seo; Grant T Gullberg
Journal:  Med Phys       Date:  2018-08-31       Impact factor: 4.071

4.  Direct 4D parametric imaging for linearized models of reversibly binding PET tracers using generalized AB-EM reconstruction.

Authors:  Arman Rahmim; Yun Zhou; Jing Tang; Lijun Lu; Vesna Sossi; Dean F Wong
Journal:  Phys Med Biol       Date:  2012-01-18       Impact factor: 3.609

5.  Nonlinear spatio-temporal filtering of dynamic PET data using a four-dimensional Gaussian filter and expectation-maximization deconvolution.

Authors:  J M Floberg; J E Holden
Journal:  Phys Med Biol       Date:  2013-02-21       Impact factor: 3.609

6.  Dynamic positron emission tomography image restoration via a kinetics-induced bilateral filter.

Authors:  Zhaoying Bian; Jing Huang; Jianhua Ma; Lijun Lu; Shanzhou Niu; Dong Zeng; Qianjin Feng; Wufan Chen
Journal:  PLoS One       Date:  2014-02-27       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.