Abstract

We present a direct method for producing images of kinetic parameters from list mode PET data. The time-activity curve for each voxel is described by a one-tissue compartment, 2-parameter model. Extending previous EM algorithms, a new spatiotemporal complete data space was introduced to optimize the maximum likelihood function. This leads to a straightforward parametric image update equation with moderate additional computation requirements compared to the conventional algorithm. Qualitative and quantitative evaluations were performed using 2D (x,t) and 4D (x,y,z,t) simulated list mode data for a brain receptor study. Comparisons with the two-step approach (frame-based reconstruction followed by voxel-by-voxel parameter estimation) show that the proposed method can lead to accurate estimation of the parametric image values with reduced variance, especially for the volume of distribution (V(T)).

Year:  2008        PMID: 20628540      PMCID: PMC2901873          DOI: 10.1109/NSSMIC.2008.4774103

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  11 in total

1.  Spatiotemporal reconstruction of list-mode PET data.

Authors:  Thomas E Nichols; Jinyi Qi; Evren Asma; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2002-04       Impact factor: 10.048

2.  Direct reconstruction of kinetic parameter images from dynamic PET data.

Authors:  M E Kamasak; C A Bouman; E D Morris; K Sauer
Journal:  IEEE Trans Med Imaging       Date:  2005-05       Impact factor: 10.048

3.  A fast fully 4-D incremental gradient reconstruction algorithm for list mode PET data.

Authors:  Quanzheng Li; Evren Asma; Sangtae Ahn; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2007-01       Impact factor: 10.048

4.  Joint estimation of dynamic PET images and temporal basis functions using fully 4D ML-EM.

Authors:  Andrew J Reader; Florent C Sureau; Claude Comtat; Régine Trébossen; Irène Buvat
Journal:  Phys Med Biol       Date:  2006-10-06       Impact factor: 3.609

5.  Maximum a posteriori reconstruction of the Patlak parametric image from sinograms in dynamic PET.

Authors:  Guobao Wang; Lin Fu; Jinyi Qi
Journal:  Phys Med Biol       Date:  2008-01-10       Impact factor: 3.609

6.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography.

Authors:  Charalampos Tsoumpas; Federico E Turkheimer; Kris Thielemans
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

7.  Dynamic PET reconstruction using wavelet regularization with adapted basis functions.

Authors:  Jeroen Verhaeghe; Dimitri Van de Ville; Ildar Khalidov; Yves D'Asseler; Ignace Lemahieu; Michael Unser
Journal:  IEEE Trans Med Imaging       Date:  2008       Impact factor: 10.048

8.  Parametric image reconstruction using spectral analysis of PET projection data.

Authors:  S R Meikle; J C Matthews; V J Cunningham; D L Bailey; L Livieratos; T Jones; P Price
Journal:  Phys Med Biol       Date:  1998-03       Impact factor: 3.609

9.  The direct calculation of parametric images from dynamic PET data using maximum-likelihood iterative reconstruction.

Authors:  J Matthews; D Bailey; P Price; V Cunningham
Journal:  Phys Med Biol       Date:  1997-06       Impact factor: 3.609

10.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

View more
  8 in total

1.  Initial Evaluation of Direct 4D Parametric Reconstruction with Human PET Data.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Jean-Dominique Gallezot; Richard E Carson
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-11-01

2.  DIRECT RECONSTRUCTION OF DYNAMIC PET PARAMETRIC IMAGES USING SPARSE SPECTRAL REPRESENTATION.

Authors:  Guobao Wang; Jinyi Qi
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-08-07

3.  An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2012-08-08       Impact factor: 10.048

Review 4.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

Authors:  Geoffrey D Hugo; Mihaela Rosu
Journal:  Z Med Phys       Date:  2012-07-10       Impact factor: 4.820

5.  Direct 4D parametric imaging for linearized models of reversibly binding PET tracers using generalized AB-EM reconstruction.

Authors:  Arman Rahmim; Yun Zhou; Jing Tang; Lijun Lu; Vesna Sossi; Dean F Wong
Journal:  Phys Med Biol       Date:  2012-01-18       Impact factor: 3.609

6.  Generalized algorithms for direct reconstruction of parametric images from dynamic PET data.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048

7.  Direct 4-D PET list mode parametric reconstruction with a novel EM algorithm.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Richard E Carson
Journal:  IEEE Trans Med Imaging       Date:  2012-08-23       Impact factor: 10.048

Review 8.  Direct estimation of kinetic parametric images for dynamic PET.

Authors:  Guobao Wang; Jinyi Qi
Journal:  Theranostics       Date:  2013-11-20       Impact factor: 11.556

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.