Literature DB >> 25328471

Biomechanical performance of variable and fixed angle locked volar plates for the dorsally comminuted distal radius.

D Martineau1, J Shorez2, C Beran1, A G Dass1, P Atkinson3.   

Abstract

BACKGROUND: The ideal treatment strategy for the dorsally comminuted distal radius fracture continues to evolve. Newer plate designs allow for variable axis screw placement while maintaining the advantages of locked technology. The purpose of this study is to compare the biomechanical properties of one variable axis plate with two traditional locked constructs.
METHODS: Simulated fractures were created via a distal 1 cm dorsal wedge osteotomy in radius bone analogs. The analogs were of low stiffness and rigidity to create a worst-case strength condition for the subject radius plates. This fracture-gap model was fixated using one of three different locked volar distal radius plates: a variable axis plate (Stryker VariAx) or fixed axis (DePuy DVR, Smith & Nephew Peri-Loc) designs. The constructs were then tested at physiologic loading levels in axial compression and bending (dorsal and volar) modes. Construct stiffness was assessed by fracture gap motion during the different loading conditions. As a within-study control, intact bone analogs were similarly tested.
RESULTS: All plated constructs were significantly less stiff than the intact control bone models in all loading modes (p<0.040). Amongst the plated constructs, the VariAx was stiffest axially (p=0.032) and the Peri-Loc was stiffest in bending (p<0.024).
CONCLUSION: In this analog bone fracture gap model, the variable axis locking technology was stiffer in axial compression than other plates, though less stiff in bending.

Entities:  

Mesh:

Year:  2014        PMID: 25328471      PMCID: PMC4127713     

Source DB:  PubMed          Journal:  Iowa Orthop J        ISSN: 1541-5457


  23 in total

1.  Evaluation of healed Colles' fractures.

Authors:  J J GARTLAND; C W WERLEY
Journal:  J Bone Joint Surg Am       Date:  1951-10       Impact factor: 5.284

2.  Treatment of distal radius fractures.

Authors:  David M Lichtman; Randipsingh R Bindra; Martin I Boyer; Matthew D Putnam; David Ring; David J Slutsky; John S Taras; William C Watters; Michael J Goldberg; Michael Keith; Charles M Turkelson; Janet L Wies; Robert H Haralson; Kevin M Boyer; Kristin Hitchcock; Laura Raymond
Journal:  J Am Acad Orthop Surg       Date:  2010-03       Impact factor: 3.020

3.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

4.  A biomechanical comparison between two volar locking plate systems for distal radius fractures.

Authors:  Li Chen; Qiang Dai; Montri D Wongworawat
Journal:  Orthopedics       Date:  2006-10       Impact factor: 1.390

5.  Biomechanical evaluation of fixation of intra-articular fractures of the distal part of the radius in cadavera: Kirschner wires compared with calcium-phosphate bone cement.

Authors:  D N Yetkinler; A L Ladd; R D Poser; B R Constantz; D Carter
Journal:  J Bone Joint Surg Am       Date:  1999-03       Impact factor: 5.284

6.  Long-term trends in the incidence of distal forearm fractures.

Authors:  L J Melton; P C Amadio; C S Crowson; W M O'Fallon
Journal:  Osteoporos Int       Date:  1998       Impact factor: 4.507

7.  Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial.

Authors:  David H Wei; Noah M Raizman; Clement J Bottino; Charles M Jobin; Robert J Strauch; Melvin P Rosenwasser
Journal:  J Bone Joint Surg Am       Date:  2009-07       Impact factor: 5.284

8.  Prospective randomised study of intra-articular fractures of the distal radius: comparison between external fixation and plate fixation.

Authors:  Germaine G Q Xu; Siew Pang Chan; Mark Edward Puhaindran; Winston Y C Chew
Journal:  Ann Acad Med Singapore       Date:  2009-07       Impact factor: 2.473

9.  Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

10.  Incidence and characteristics of distal radius fractures in a southern Swedish region.

Authors:  Elisabeth Brogren; Michael Petranek; Isam Atroshi
Journal:  BMC Musculoskelet Disord       Date:  2007-05-31       Impact factor: 2.362

View more
  4 in total

1.  [The volar locking plate for extension fractures of the distal radius].

Authors:  T Pillukat; R Fuhrmann; J Windolf; J van Schoonhoven
Journal:  Oper Orthop Traumatol       Date:  2015-12-17       Impact factor: 1.154

2.  Kirschner Wire Fixation in Dorsally Displaced Distal Radius Fractures: A Biomechanical Evaluation.

Authors:  Liam Sanders; Nick Johnson; Joseph J Dias
Journal:  J Wrist Surg       Date:  2021-05-11

3.  Variable Angle Locking Compression Plate as Alternative Fixation for Jones Fractures: A Case Series.

Authors:  Kaylee A Miller; Alexander C M Chong; Timothy P Uglem
Journal:  Kans J Med       Date:  2019-05-15

4.  Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?

Authors:  Mohamed Abdel-Wahed; Ahmed Abdel-Zaher Khater; Mahmoud Ahmed El-Desouky
Journal:  Int Orthop       Date:  2022-06-11       Impact factor: 3.479

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.