Literature DB >> 16937208

Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study.

Chun-Li Lin1, Yu-Hao Lin, Alvin Chao-Yu Chen.   

Abstract

Treatment of a distal radius fracture should consider principles including stable fixation and early motion. The aim of this study was to investigate the biomechanical interactions of plate-fixation angles in the internal double-plating method coupled with various load conditions using non-linear finite element analysis (FEA). A 3D finite element distal radius fracture model with three separation angles (50, 70, and 90 degrees ) between the buttressed L- and straight plates was generated based on computed tomography data. After model verification and validation, frictional (contact) elements were used to simulate the interface condition between the fixation plates and the bony surface. The stress/strain distributions and displacements at the radius end were observed under axial, bending, and torsion load conditions. The simulated results indicated that the bending and torsion increased the stress values more than the axial load. The radius and straight plate stress values decreased significantly with increasing fixation angles for all load conditions. However, the L-plate stress values increased slightly under the bending buckling effect. The displacements at the radius end and strains at the fracture healing interface decreased with increasing fixation angles for axial and torsion conditions but displayed a slight difference for the bending condition. The findings using FEA provide quantitative evidence to identify that much larger plate fixation angles could provide better mechanical strength to establish favorable stress-transmission and prevent distal fragment dislocation.

Entities:  

Mesh:

Year:  2006        PMID: 16937208     DOI: 10.1007/s11517-006-0082-9

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  28 in total

1.  Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation.

Authors:  M D Putnam; N J Meyer; E W Nelson; D Gesensway; J L Lewis
Journal:  J Hand Surg Am       Date:  2000-05       Impact factor: 2.230

2.  Finite element analysis of the mechanical behavior of a scapula implanted with a glenoid prosthesis.

Authors:  B Couteau; P Mansat; E Estivalèzes; R Darmana; M Mansat; J Egan
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001-08       Impact factor: 2.063

3.  In vivo determination of contact areas and pressure of the femorotibial joint using non-linear finite element analysis.

Authors:  D. Périé; M.C. Hobatho
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-09       Impact factor: 2.063

4.  Intramedullary nails with two lag screws.

Authors:  C J Brown; C J Wang; A L Yettram; P Procter
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-06       Impact factor: 2.063

5.  Effect on force transmission across the carpus in procedures used to treat Kienböck's disease.

Authors:  E Horii; M Garcia-Elias; A T Bishop; W P Cooney; R L Linscheid; E Y Chao
Journal:  J Hand Surg Am       Date:  1990-05       Impact factor: 2.230

6.  Finite element analysis of a novel design approach to resisting total hip dislocation.

Authors:  C F Scifert; T D Brown; J D Lipman
Journal:  Clin Biomech (Bristol, Avon)       Date:  1999-12       Impact factor: 2.063

7.  Supplemental pinning improves the stability of external fixation in distal radius fractures during simulated finger and forearm motion.

Authors:  C E Dunning; C S Lindsay; R T Bicknell; S D Patterson; J A Johnson; G J King
Journal:  J Hand Surg Am       Date:  1999-09       Impact factor: 2.230

8.  Forces in the normal and abnormal hand.

Authors:  K N An; E Y Chao; W P Cooney; R L Linscheid
Journal:  J Orthop Res       Date:  1985       Impact factor: 3.494

9.  Influence of the stiffness of bone defect implants on the mechanical conditions at the interface--a finite element analysis with contact.

Authors:  U Simon; P Augat; A Ignatius; L Claes
Journal:  J Biomech       Date:  2003-08       Impact factor: 2.712

10.  Fracture of the distal radius: classification of treatment and indications for external fixation.

Authors:  S Graff; J Jupiter
Journal:  Injury       Date:  1994       Impact factor: 2.586

View more
  5 in total

1.  Strength analysis of clavicle fracture fixation devices and fixation techniques using finite element analysis with musculoskeletal force input.

Authors:  Cronskär Marie
Journal:  Med Biol Eng Comput       Date:  2015-04-08       Impact factor: 2.602

2.  Validation of a new multiscale finite element analysis approach at the distal radius.

Authors:  Joshua E Johnson; Karen L Troy
Journal:  Med Eng Phys       Date:  2017-03-31       Impact factor: 2.242

3.  Finite element analysis of osteosynthesis screw fixation in the bone stock: an appropriate method for automatic screw modelling.

Authors:  Jan Wieding; Robert Souffrant; Andreas Fritsche; Wolfram Mittelmeier; Rainer Bader
Journal:  PLoS One       Date:  2012-03-28       Impact factor: 3.240

4.  Feasibility of a braided composite for orthopedic bone cast.

Authors:  Katherine R Evans; Jason P Carey
Journal:  Open Biomed Eng J       Date:  2013-01-15

5.  Biomechanical comparison of osteoporotic distal radius fractures fixed by distal locking screws with different length.

Authors:  Xiong Liu; Wei-dong Wu; Ya-feng Fang; Mei-chao Zhang; Wen-hua Huang
Journal:  PLoS One       Date:  2014-07-31       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.