Literature DB >> 23275031

Volar fixation of distal radial fracture using compression plate: clinical and radiographic evaluation of 20 patients.

S Giannotti1, P Alfieri, L Magistrelli, F Casella, L Palmeri, G Guido.   

Abstract

Distal radius fractures can be treated with different methods, depending on the type of fracture and, on our experience, according to the Fernandez algorithm. The report presents our experience treating distal radius fractures using a volar plate. We reviewed retrospectively 20 patients treated, during a period of 3 years (May 2008-May 2011) at our center, for unstable distal radius fractures using a volar plate. All patients were reviewed by thorough clinical examination and standard radiographs of the operated wrist. For the clinical evaluation, we used Mayo Wrist Score and DASH Score. At review, the injured wrist had recovered an average range of motion in flexion-extension of 120°, and the grip strength was an average of 50% compared to contralateral side. Overall, results at Mayo Wrist Score were good to excellent in 30%, satisfactory in 55%, and poor in 15%; results at DASH Score were good to excellent in 90%, satisfactory in 10% with no poor case. The majority of patients were fully satisfied with the results (65%), 20% of patients were partially satisfied, 5% were poorly satisfied, and 10% were not satisfied. At review, 4 patients reported the presence of transient paresthesia localized to the first three rays of the hand. At radiographic evaluation, the majority of patients had a radial tilt between 20 and 23, ulnar variance between 0 and 3, and dorsal tilt between 9 and 14. The treatment of unstable distal radius fractures with a volar plate provided stable internal fixation and allowed early function and was associated with a low complication rate.

Entities:  

Mesh:

Year:  2012        PMID: 23275031     DOI: 10.1007/s12306-012-0238-8

Source DB:  PubMed          Journal:  Musculoskelet Surg        ISSN: 2035-5114


  22 in total

Review 1.  Volar plate fixation of distal radius fractures.

Authors:  Jorge Orbay
Journal:  Hand Clin       Date:  2005-08       Impact factor: 1.907

2.  Radiographic measurements of the radio-carpal joint in normal adults.

Authors:  S Friberg; B Lundström
Journal:  Acta Radiol Diagn (Stockh)       Date:  1976-03

3.  Effect on force transmission across the carpus in procedures used to treat Kienböck's disease.

Authors:  E Horii; M Garcia-Elias; A T Bishop; W P Cooney; R L Linscheid; E Y Chao
Journal:  J Hand Surg Am       Date:  1990-05       Impact factor: 2.230

4.  Fracture of the distal radius including sequelae--shoulder-hand-finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function. A clinical and experimental study.

Authors:  G Frykman
Journal:  Acta Orthop Scand       Date:  1967

5.  Volar fixation of dorsally displaced distal radial fracture using locking compression plate.

Authors:  K K Wong; K W Chan; T K Kwok; K H Mak
Journal:  J Orthop Surg (Hong Kong)       Date:  2005-08       Impact factor: 1.118

6.  [Unstable fracture of the distal radius and its treatment: comparison of three techniques: external fixation, intramedullary pinning and AO plates].

Authors:  G R Sennwald; D Della Santa
Journal:  Chir Main       Date:  2001-06

7.  Humeral bone fragility in patients with shoulder prosthesis: a case of humeral periprosthetic refracture.

Authors:  Stefano Giannotti; Vanna Bottai; Giacomo Dell'osso; Daniela Donati; Giulia Bugelli; Gaia De Paola; Giulio Guido
Journal:  Clin Cases Miner Bone Metab       Date:  2012-05-29

8.  The effects of osteoporosis on functional outcome in patients with distal radius fracture treated with plate osteosynthesis.

Authors:  Cem Dinçay Büyükkurt; Murat Bülbül; Semih Ayanoğlu; Cem Zeki Esenyel; Kahraman Oztürk; Hakan Gürbüz
Journal:  Acta Orthop Traumatol Turc       Date:  2012       Impact factor: 1.511

9.  Augmented external fixation of distal radius fractures: a biomechanical analysis.

Authors:  S W Wolfe; C R Swigart; J Grauer; J F Slade; M M Panjabi
Journal:  J Hand Surg Am       Date:  1998-01       Impact factor: 2.230

10.  Intra-articular fractures of the distal end of the radius in young adults.

Authors:  J L Knirk; J B Jupiter
Journal:  J Bone Joint Surg Am       Date:  1986-06       Impact factor: 5.284

View more
  2 in total

1.  Efficacy of volar and dorsal plate fixation for unstable dorsal distal radius fractures.

Authors:  Chang-Hong Chen; Rong-Kui Zhou; Hua-Qing Zhen; Lei Huang; Ya-Jun Jiao
Journal:  Int J Clin Exp Med       Date:  2015-03-15

2.  Comparison of outcome of VLCP versus PKEF in the treatment of AO type C2-3 distal radial fractures.

Authors:  Zhibing Tang; Jinlian Liu; Huilin Yang
Journal:  Ann Med Surg (Lond)       Date:  2017-05-13
  2 in total