Proposal for standardizing direct-reading biosensors for blood glucose.

N Fogh-Andersen1, P D'Orazio.   

Abstract

Direct-reading glucose biosensors sense molality (glucose per unit water mass) in the sample. With aqueous calibration, a direct-reading glucose biosensor produces higher results in blood and plasma than methods measuring concentration, theoretically by the ratio of water concentrations in calibrator and sample. To confirm this, we measured glucose in 14- blood and 40 plasma samples with the direct-reading glucose sensor in the Chiron Model 860 Blood Gas and Critical Analyte System and with our routine method (ESAT 6660; Eppendorf). The Chiron instrument is calibrated with a 10 mmol/L (180 mg/dL0 glucose calibrator (mass concentration of water = 0.99 kg/L). Assuming normal water concentrations of 0.84 and 0.93 kg/L in blood and plasma, respectively, we multiplied results from the Chiron sensor by 0.84/0.99 and 0.93/0.99 to obtain concentrations in blood and plasma. This conversion resulted in agreement of results with our routine method. An individual conversion based on hematocrit in each whole-blood sample was less satisfactory. To avoid confusion over variously measured and reported glucose results and reference values, we suggest standardization and reporting of whole-blood glucose results as equivalent plasma concentrations. This proposal may be conveniently achieved by using a commercially available reference material for glucose, NIST SRM 965.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9510875

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  13 in total

1.  Analysis of an electrochemical blood glucose monitoring system with hematocrit compensation: improved accuracy by design.

Authors:  Martha E Lyon; Andrew W Lyon
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

Review 2.  Challenges of inpatient blood glucose monitoring: standards, methods, and devices to measure blood glucose.

Authors:  Kathie L Hermayer; Aundrea S Loftley; Sumana Reddy; Satya Nandana Narla; Nina A Epps; Yusheng Zhu
Journal:  Curr Diab Rep       Date:  2015-03       Impact factor: 4.810

3.  Uncertainties in the measurement of blood glucose in paediatric intensive care: implications for clinical trials of tight glycaemic control.

Authors:  Helen Hill; Paul Baines; Paul Barton; Paul Newland; Dianne Terlouw; Mark Turner
Journal:  Intensive Care Med       Date:  2011-07-09       Impact factor: 17.440

4.  Measurement of glucose in blood with a phenylboronic acid optical sensor.

Authors:  Graham J Worsley; Guilhem A Tourniaire; Kathryn E S Medlock; Felicity K Sartain; Hazel E Harmer; Michael Thatcher; Adrian M Horgan; John Pritchard
Journal:  J Diabetes Sci Technol       Date:  2008-03

5.  Periodic extraction of interstitial fluid from the site of subcutaneous insulin infusion for the measurement of glucose: a novel single-port technique for the treatment of type 1 diabetes patients.

Authors:  Werner Regittnig; Stefan Lindpointner; Stefan Korsatko; Dina Tutkur; Manfred Bodenlenz; Thomas R Pieber
Journal:  Diabetes Technol Ther       Date:  2012-11-05       Impact factor: 6.118

6.  Estimates of total analytical error in consumer and hospital glucose meters contributed by hematocrit, maltose, and ascorbate.

Authors:  Martha E Lyon; Jeffrey A DuBois; Gordon H Fick; Andrew W Lyon
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

7.  Accuracy of bedside capillary blood glucose measurements in critically ill patients.

Authors:  C Dana Critchell; Vincent Savarese; Amy Callahan; Christine Aboud; Serge Jabbour; Paul Marik
Journal:  Intensive Care Med       Date:  2007-09-01       Impact factor: 17.440

8.  Evaluation of the VIA Blood Chemistry Monitor for Glucose in Healthy and Diabetic Volunteers.

Authors:  Arjunan Ganesh; Brian Hipszer; Navdeep Loomba; Barbara Simon; Marc C Torjman; Jeffrey Joseph
Journal:  J Diabetes Sci Technol       Date:  2008-03

9.  Blood glucose measurements in the critically ill: more than just a blood draw.

Authors:  Frank M Brunkhorst; Hans G Wahl
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

10.  Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle.

Authors:  A A Megahed; M W H Hiew; J R Townsend; J B Messick; P D Constable
Journal:  J Vet Intern Med       Date:  2015-10-20       Impact factor: 3.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.