Challenges of inpatient blood glucose monitoring: standards, methods, and devices to measure blood glucose.

Kathie L Hermayer1, Aundrea S Loftley, Sumana Reddy, Satya Nandana Narla, Nina A Epps, Yusheng Zhu.   

Abstract

Glucose control in the hospital setting is very important. There is a high incidence of hyperglycemia, hypoglycemia, and glycemic variability in hospitalized patients. Safe insulin delivery and glucose control is dependent on reliable glucose meters and monitoring systems in the hospital. Different glucose monitoring systems use arterial, venous, central venous, and capillary blood samples. It is important for clinicians to be aware that there are limitations of specific point-of-care (POC) glucose meters and that situations exist whereby POC glucose meters as the sole measurement device should be avoided. POC meter devices are not approved by the Food and Drug Administration for use in critical care, although POC meter devices are commonly used in critical care settings and elsewhere. This review focuses on glucose assay principles, instrument technology, influences on glucose measurement, standards for glucose measurement, and an evaluation of different methods to measure blood glucose in the hospital setting.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25644818     DOI: 10.1007/s11892-015-0582-9

Source DB:  PubMed          Journal:  Curr Diab Rep        ISSN: 1534-4827            Impact factor:   4.810


  32 in total

1.  Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing.

Authors:  Z Tang; J H Lee; R F Louie; G J Kost
Journal:  Arch Pathol Lab Med       Date:  2000-08       Impact factor: 5.534

2.  Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction.

Authors:  Lokinendi V Rao; Felice Jakubiak; James S Sidwell; James W Winkelman; Michael L Snyder
Journal:  Clin Chim Acta       Date:  2005-03-31       Impact factor: 3.786

Review 3.  How accurately do we measure blood glucose levels in intensive care unit (ICU) patients?

Authors:  Hans Günther Wahl
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2009-12

4.  Proposal for standardizing direct-reading biosensors for blood glucose.

Authors:  N Fogh-Andersen; P D'Orazio
Journal:  Clin Chem       Date:  1998-03       Impact factor: 8.327

5.  Clinical evaluation of the FreeStyle Precision Pro system.

Authors:  Ronald Brazg; Kristen Hughes; Pamela Martin; Julie Coard; John Toffaletti; Elizabeth McDonnell; Elizabeth Taylor; Lausanne Farrell; Mona Patel; Jeanne Ward; Ting Chen; Shridhara Alva; Ronald Ng
Journal:  Clin Chim Acta       Date:  2013-03-26       Impact factor: 3.786

6.  Can one point-of-care glucose meter be used for all pediatric and adult hospital patients? Evaluation of three meters, including recently modified test strips.

Authors:  Janet V Warner; Joyce Y Wu; Nita Buckingham; Donald S A McLeod; Barbara Mottram; Andrew C Carter
Journal:  Diabetes Technol Ther       Date:  2011-01       Impact factor: 6.118

7.  Analysis of blood glucose measurements using capillary and arterial blood samples in intensive care patients.

Authors:  Atul Kulkarni; Manoj Saxena; Grant Price; Michael J O'Leary; Theresa Jacques; John A Myburgh
Journal:  Intensive Care Med       Date:  2004-11-23       Impact factor: 17.440

8.  The food and drug administration is now preparing to establish tighter performance requirements for blood glucose monitors.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

Review 9.  Point-of-care testing for diabetes.

Authors:  Deirdre R Blake; David M Nathan
Journal:  Crit Care Nurs Q       Date:  2004 Apr-Jun

10.  Assessing the impact of blood sample type on the estimated prevalence of impaired glucose tolerance and diabetes mellitus in epidemiological surveys.

Authors:  M Farrer; C J Albers; H A Neil; P C Adams; M F Laker; K G Alberti
Journal:  Diabet Med       Date:  1995-04       Impact factor: 4.359

View more
  3 in total

1.  Evaluation of the Abbot FreeStyle Optium Neo H blood glucose meter in the hyperbaric oxygen environment.

Authors:  Carol R Baines; P David Cooper; Geraldine A O'Rourke; Charne Miller
Journal:  Diving Hyperb Med       Date:  2020-06-30       Impact factor: 0.887

Review 2.  Measurement of Hyperglycemia and Impact on Health Outcomes in People With Cancer: Challenges and Opportunities.

Authors:  Susan Storey; Diane Von Ah; Marilyn J Hammer
Journal:  Oncol Nurs Forum       Date:  2017-07-01       Impact factor: 2.172

3.  A Flexible Dual-Analyte Electrochemical Biosensor for Salivary Glucose and Lactate Detection.

Authors:  Mingyang Liu; Muqun Yang; Muxue Wang; Han Wang; Jing Cheng
Journal:  Biosensors (Basel)       Date:  2022-03-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.