Literature DB >> 33816100

Stress distribution around different abutments on titanium and CFR-PEEK implant with different prosthetic crowns under parafunctional loading: A 3D FEA study.

Akanksha Mourya1, Rajvi Nahar1, Sunil Kumar Mishra2, Ramesh Chowdhary3.   

Abstract

AIM &
OBJECTIVES: Clinical trials had concluded a significant relationship between implant failure and bruxism. A three-dimensional (3D) finite element analysis (FEA) was done to evaluate the stress distribution in straight and angled abutments around titanium and carbon fiber-reinforced polyetheretherketone (CFR-PEEK) implant with 2 different prosthetic crowns under parafunctional loading. MATERIALS AND
METHOD: Twelve 3D models of bone block were created representing the maxillary right premolar area with osseointegrated implants. The models were divided in two group; CFR-PEEK implant (n ​= ​6) and group titanium implant (n ​= ​6).Each group was subdivided based on implants with three different abutments (straight, 15°, 25° angled abutments) and having two different prosthetic crowns: porcelain fused to metal (PFM) and polyetheretherketone (PEEK). A vertical load of 1000 ​N was applied to the central fossa and an oblique load of 500 ​N (30°) was applied to the buccal incline of the palatal cusp. The von Mises stresses and principal stresses were analyzed using ANSYS software.
RESULTS: CFR-PEEK and titanium implants produced similar stress in bone under vertical and oblique loading. Straight abutment showed better results than 15° and 25° angled abutments in all the groups. PEEK crown produced lesser stress than PFM crown under vertical and oblique loading.
CONCLUSION: The study concluded that straight abutment along with PEEK crown could be given in patients with bruxism to reduce the stress concentration in bone, thus preventing possible implant failure. Titanium and CFR-PEEK implants with straight abutments if given, then it should be provided with an occlusal splint.
© 2021 Craniofacial Research Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Year:  2021        PMID: 33816100      PMCID: PMC8005827          DOI: 10.1016/j.jobcr.2021.03.005

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  27 in total

1.  In vivo registration of force development with ceramic and acrylic resin occlusal materials on implant-supported prostheses.

Authors:  Roger Bassit; Håkan Lindström; Bo Rangert
Journal:  Int J Oral Maxillofac Implants       Date:  2002 Jan-Feb       Impact factor: 2.804

Review 2.  Angled implant abutments: a practical application of available knowledge.

Authors:  John Cavallaro; Gary Greenstein
Journal:  J Am Dent Assoc       Date:  2011-02       Impact factor: 3.634

3.  Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone.

Authors:  A D Schwitalla; M Abou-Emara; T Spintig; J Lackmann; W D Müller
Journal:  J Biomech       Date:  2014-11-20       Impact factor: 2.712

4.  Immediate occlusal loading of Brånemark implants applied in various jawbone regions: a prospective, 1-year clinical study.

Authors:  R Glauser; A Rée; A Lundgren; J Gottlow; C H Hämmerle; P Schärer
Journal:  Clin Implant Dent Relat Res       Date:  2001       Impact factor: 3.932

5.  Composite technology for total hip arthroplasty.

Authors:  H B Skinner
Journal:  Clin Orthop Relat Res       Date:  1988-10       Impact factor: 4.176

6.  Parafunctional loading and occlusal device on stress distribution around implants: A 3D finite element analysis.

Authors:  Manuel Tomás Borges Radaelli; Henrique Takashi Idogava; Aloisio Oro Spazzin; Pedro Yoshito Noritomi; Noéli Boscato
Journal:  J Prosthet Dent       Date:  2018-04-30       Impact factor: 3.426

7.  Parafunctional habits, nightguards, and root form implants.

Authors:  M L Perel
Journal:  Implant Dent       Date:  1994       Impact factor: 2.454

8.  A prospective randomized study of 1- and 2-stage sinus inlay bone grafts: 1-year follow-up.

Authors:  K Wannfors; B Johansson; M Hallman; T Strandkvist
Journal:  Int J Oral Maxillofac Implants       Date:  2000 Sep-Oct       Impact factor: 2.804

9.  Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function.

Authors:  U Brägger; S Aeschlimann; W Bürgin; C H Hämmerle; N P Lang
Journal:  Clin Oral Implants Res       Date:  2001-02       Impact factor: 5.977

10.  Bruxism and dental implant failures: a multilevel mixed effects parametric survival analysis approach.

Authors:  B R Chrcanovic; J Kisch; T Albrektsson; A Wennerberg
Journal:  J Oral Rehabil       Date:  2016-09-09       Impact factor: 3.837

View more
  2 in total

1.  The Structural Integrity and Fracture Behaviour of Teeth Restored with PEEK and Lithium-Disilicate Glass Ceramic Crowns.

Authors:  Sami Aldhuwayhi; Muhammad Syafiq Alauddin; Nicolas Martin
Journal:  Polymers (Basel)       Date:  2022-03-01       Impact factor: 4.329

2.  Stress Distribution Pattern in Zygomatic Implants Supporting Different Superstructure Materials.

Authors:  Artak Heboyan; Roberto Lo Giudice; Les Kalman; Muhammad Sohail Zafar; João Paulo Mendes Tribst
Journal:  Materials (Basel)       Date:  2022-07-16       Impact factor: 3.748

  2 in total