Literature DB >> 9479741

The use of bipolar cautery, laparosonic coagulating shears, and vascular clips for hemostasis of small and medium-sized vessels.

H Spivak1, W S Richardson, J G Hunter.   

Abstract

Advanced laparoscopic surgery requires a reliable method of hemostasis. In order to determine the efficacy of common hemostatic devices, we tested bipolar electrosurgery (BPES), laparosonic coagulating shears (LCS), and vascular clips (VC) on arteries of various sizes to compare the strength of hemostasis against elevated intraarterial pressure. The procedures were performed on a porcine model through a laparotomy. Segments of visceral arteries were isolated and cannulated with an angiocatheter that was linked to a pressure monitor. After hemostasis with the tested instrument and division of the vessel, the intraarterial pressure was elevated by infusion of saline solution through the angiocatheter. The pressure was recorded when bleeding occurred through the cut end of the vessel or when the pressure reached 300 mm Hg. All three devices were effective in maintaining hemostasis on small (diameter, 0.25-0.5 mm) and medium-sized arteries (diameter, 2-3.5 mm) with a success rate ranging between 75% and 100% (p = n.s.). Practice and technical finesse were required with the use of the LCS and BPES before excellent results could be obtained. The LCS has an advantage over BPES because it allows the surgeon to perform hemostasis and division simultaneously, thus keeping the operating field clean and avoiding instrument adhesion to the tissue.

Entities:  

Mesh:

Year:  1998        PMID: 9479741     DOI: 10.1007/s004649900627

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  22 in total

1.  Initial results with an electrothermal bipolar vessel sealer.

Authors:  B T Heniford; B D Matthews; R F Sing; C Backus; B Pratt; F L Greene
Journal:  Surg Endosc       Date:  2001-05-14       Impact factor: 4.584

2.  Real-time thermography during energized vessel sealing and dissection.

Authors:  P A Campbell; A B Cresswell; T G Frank; A Cuschieri
Journal:  Surg Endosc       Date:  2003-07-21       Impact factor: 4.584

3.  Thermal fusion: effects and interactions of temperature, compression, and duration variables.

Authors:  Deogracias A G Reyes; Stuart I Brown; Lynda Cochrane; Luisa S Motta; Alfred Cuschieri
Journal:  Surg Endosc       Date:  2012-07-07       Impact factor: 4.584

4.  Experimental evaluation of bursting pressure in lymphatic vessels with ultrasonically activated shears.

Authors:  Kaoru Abe; Masanori Terashima; Hisataka Fujiwara; Akinori Takagane; Noriyuki Uesugi; Kazuyoshi Saito
Journal:  World J Surg       Date:  2005-01       Impact factor: 3.352

5.  Efficacy and quality of vessel sealing: comparison of a reusable with a disposable device and effects of clamp surface geometry and structure.

Authors:  S Richter; O Kollmar; M K Schilling; G A Pistorius; M D Menger
Journal:  Surg Endosc       Date:  2006-05-12       Impact factor: 4.584

6.  Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries.

Authors:  K L Harold; H Pollinger; B D Matthews; K W Kercher; R F Sing; B T Heniford
Journal:  Surg Endosc       Date:  2003-06-13       Impact factor: 4.584

7.  Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices.

Authors:  William L Newcomb; William W Hope; Thomas M Schmelzer; Jessica J Heath; H James Norton; Amy E Lincourt; B Todd Heniford; David A Iannitti
Journal:  Surg Endosc       Date:  2008-05-16       Impact factor: 4.584

8.  Bipolar vessel sealing: instrument contamination and wear have little effect on seal quality and success in a porcine in vitro model.

Authors:  Christian W Wallwiener; Susanna H Junginger; Wolfgang Zubke; Sara Y Brucker; Markus D Enderle; Alexander Neugebauer; Birgitt Schönfisch; Markus Wallwiener
Journal:  Langenbecks Arch Surg       Date:  2014-07-27       Impact factor: 3.445

9.  Comparison of various methods of vessel ligation: what is the safest method?

Authors:  Chang-Sup Lim; Jin-Young Jang; Seung Eun Lee; You Jeong Lee; Mee Joo Kang; Sun-Whe Kim
Journal:  Surg Endosc       Date:  2013-03-07       Impact factor: 4.584

10.  In vivo comparison of the coagulation capability of SonoSurg and Harmonic Ace on 4 mm and 5 mm arteries.

Authors:  Ronald H Clements; Rajendra Palepu
Journal:  Surg Endosc       Date:  2007-05-04       Impact factor: 4.584

View more