Real-time thermography during energized vessel sealing and dissection.

P A Campbell1, A B Cresswell, T G Frank, A Cuschieri.   

Abstract

BACKGROUND: Energized dissection systems facilitate laparoscopic dissection and hemostasis and reduce instrument traffic. However, they can introduce undesirable thermal collateral/proximity damage to adjacent structures mainly by heat conduction, although other mechanisms may be involved. The latest generation devices have the potential to reduce the incidence of such problems through use of active feedback control over the power output. This effectively regulates the delivery of energy to the target tissue with minimal thermal collateral damage. In addition, innovative heat-sink engineering of the device head ensures that the surface of the instrument tip remains cool (<45 degrees C). In this study, we evaluated the performance of this technology (LigaSure) by using dynamic infrared thermography. The thermal imaging measurements were then correlated with histopathologic studies. The overall value of in situ thermography as an adjunct to energized surgical dissection systems was also assessed.
METHODS: Eight anesthetized pigs underwent open surgery to mobilize eight target vessels/organs in a randomized fashion. The LigaSure vessel sealing system with Instant Response Technology was used with three different interchangeable heads. In situ dynamic thermography was undertaken with a thermal imaging camera operating in the mid-infrared (3-5 microm) waveband and with each fully digitized 12-bit thermographic frame acquired at a rate of 60 Hz. Following sacrifice at the end of the dissection, tissue from the dissected regions was harvested for histology by an independent pathologist who was blinded to the thermographic data.
RESULTS: Seals made with both the LS1000 5-mm laparoscopic head (predominantly to the small bowel and colon) and the LS1100 10-mm (Atlas) device (on the liver and short gastric tissues) were outwardly satisfactory. The average thermal spread [see text] with the LS1000 was = [see text] 4.4 mm, and the exposed surface of the instrument tip developed a temperature of approximately 100 degrees C. This instrument thus has the potential, albeit small, for heat-related proximity iatrogenic injury. The more technologically advanced LS1100 10-mm laparoscopic instrument exhibited a superior performance, with [see text] = 1.8 mm, and with a maximal temperature on the exposed surface of the jaws well within tolerable limits (approximately 35 degrees C) for use during surgery (laparoscopic or open). This was confirmed by histological studies that demonstrated negligible evidence of thermal damage.
CONCLUSIONS: In situ thermal imaging represents a powerful modality for the monitoring of energized dissection/coagulation during surgery. The LigaSure system used with the LS1100 head constitutes a very safe option for energized dissection and hemostasis of vessels with a diameter of up to approximately 7 mm.

Entities:  

Mesh:

Year:  2003        PMID: 12874690     DOI: 10.1007/s00464-002-8781-2

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  10 in total

1.  Initial results with an electrothermal bipolar vessel sealer.

Authors:  B T Heniford; B D Matthews; R F Sing; C Backus; B Pratt; F L Greene
Journal:  Surg Endosc       Date:  2001-05-14       Impact factor: 4.584

2.  Use of a computer-controlled bipolar diathermy system in radical prostatectomies and other open urological surgery.

Authors:  S Sengupta; D R Webb
Journal:  ANZ J Surg       Date:  2001-09       Impact factor: 1.872

3.  Sealing of cystic duct with bipolar electrocoagulation.

Authors:  S Schulze; V B Krisitiansen; B Fischer Hansen; J Rosenberg
Journal:  Surg Endosc       Date:  2001-11-12       Impact factor: 4.584

4.  Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery.

Authors:  T Kinoshita; E Kanehira; K Omura; K Kawakami; Y Watanabe
Journal:  Surg Endosc       Date:  1999-06       Impact factor: 4.584

5.  The use of bipolar cautery, laparosonic coagulating shears, and vascular clips for hemostasis of small and medium-sized vessels.

Authors:  H Spivak; W S Richardson; J G Hunter
Journal:  Surg Endosc       Date:  1998-02       Impact factor: 4.584

6.  Changes in birefringence as markers of thermal damage in tissues.

Authors:  S Thomsen; J A Pearce; W F Cheong
Journal:  IEEE Trans Biomed Eng       Date:  1989-12       Impact factor: 4.538

7.  High-burst-strength, feedback-controlled bipolar vessel sealing.

Authors:  J S Kennedy; P L Stranahan; K D Taylor; J G Chandler
Journal:  Surg Endosc       Date:  1998-06       Impact factor: 4.584

8.  The mechanism of blood vessel closure by high frequency electrocoagulation.

Authors:  B Sigel; M R Dunn
Journal:  Surg Gynecol Obstet       Date:  1965-10

9.  Development and initial application of a real time thermal control system for laser tissue welding.

Authors:  S D Klioze; D P Poppas; C T Rooke; T J Choma; S M Schlossberg
Journal:  J Urol       Date:  1994-08       Impact factor: 7.450

10.  Randomized clinical trial of Ligasure versus open haemorrhoidectomy.

Authors:  F F Palazzo; D L Francis; M A Clifton
Journal:  Br J Surg       Date:  2002-02       Impact factor: 6.939

  10 in total
  38 in total

1.  Radiofrequency versus conventional diathermy Milligan-Morgan hemorrhoidectomy: a prospective, randomized study.

Authors:  Luana Franceschilli; Vito M Stolfi; Stefano D' Ugo; Giulio P Angelucci; Sara Lazzaro; Emanuele Picone; Achille Gaspari; Pierpaolo Sileri
Journal:  Int J Colorectal Dis       Date:  2011-04-26       Impact factor: 2.571

2.  Heat production, nerve function, and morphology following nerve close dissection with surgical instruments.

Authors:  Johan Carlander; C Koch; L Brudin; C Nordborg; O Gimm; K Johansson
Journal:  World J Surg       Date:  2012-06       Impact factor: 3.352

3.  Thermal fusion: effects and interactions of temperature, compression, and duration variables.

Authors:  Deogracias A G Reyes; Stuart I Brown; Lynda Cochrane; Luisa S Motta; Alfred Cuschieri
Journal:  Surg Endosc       Date:  2012-07-07       Impact factor: 4.584

4.  In vivo thermography during small bowel fusion using radiofrequency energy.

Authors:  C Beverly B Lim; Robert D Goldin; Daniel S Elson; Ara Darzi; George B Hanna
Journal:  Surg Endosc       Date:  2010-03-31       Impact factor: 4.584

5.  Electrothermal bipolar vessel ligation improves operative time during laparoscopic total proctocolectomy: a large single-center experience.

Authors:  Richard Garfinkle; Marylise Boutros; Neha Hippalgaonkar; Geva Maimon; Giovanna da Silva; Fabio Potenti; Steven D Wexner
Journal:  Surg Endosc       Date:  2015-10-28       Impact factor: 4.584

6.  Efficacy and quality of vessel sealing: comparison of a reusable with a disposable device and effects of clamp surface geometry and structure.

Authors:  S Richter; O Kollmar; M K Schilling; G A Pistorius; M D Menger
Journal:  Surg Endosc       Date:  2006-05-12       Impact factor: 4.584

7.  Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT).

Authors:  F J Kim; M F Chammas; E Gewehr; M Morihisa; F Caldas; E Hayacibara; M Baptistussi; F Meyer; A C Martins
Journal:  Surg Endosc       Date:  2007-11-20       Impact factor: 4.584

8.  Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments.

Authors:  Gianlorenzo Dionigi
Journal:  Langenbecks Arch Surg       Date:  2008-12-24       Impact factor: 3.445

9.  Thermal spread and heat absorbance differences between open and laparoscopic surgeries during energized dissections by electrosurgical instruments.

Authors:  C Song; B Tang; P A Campbell; A Cuschieri
Journal:  Surg Endosc       Date:  2009-03-19       Impact factor: 4.584

10.  Use of BiClamp decreased the severity of hypocalcemia after total thyroidectomy compared with LigaSure: a prospective study.

Authors:  Elie Oussoultzoglou; Fabrizio Panaro; Edoardo Rosso; Ion Zeca; Philippe Bachellier; Patrick Pessaux; Daniel Jaeck
Journal:  World J Surg       Date:  2008-09       Impact factor: 3.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.