Literature DB >> 18483824

Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices.

William L Newcomb1, William W Hope, Thomas M Schmelzer, Jessica J Heath, H James Norton, Amy E Lincourt, B Todd Heniford, David A Iannitti.   

Abstract

BACKGROUND: Bipolar electrosurgical devices and ultrasonic devices are routinely used in open and advanced laparoscopic surgery for hemostasis. New electrosurgical and ultrasonic instruments demonstrate improved quality and efficiency in blood vessel sealing.
METHODS: The 5-mm laparoscopic Gyrus PKS Cutting Forceps (PK), Gyrus Plasma Trissector (GP), Harmonic Scalpel (HS), EnSeal Tissue Sealing and Hemostasis System (RX), LigaSure V with LigaSure Vessel Sealing Generator (LS), LigaSure V with Force Triad Generator (FT), and Ligamax 5 Endoscopic Multiple Clip Applier (LM) were tested to compare burst pressure, sealing time, and failure rate. Each device was used to seal 13 small (2-3 mm diameter), 13 medium (4-5 mm diameter), and 13 large (6-7 mm diameter) arteries from euthanized pigs. A p value <0.05 was considered statistically significant.
RESULTS: Mean burst pressures were not statistically different for 2-3 mm or 6-7 mm vessels. For 4-5 mm vessels, LS had the highest mean burst pressure recorded. Mean seal times were shorter for every vessel size when FT was compared with LS (p < 0.05). The shortest sealing times for 2-3 mm vessels were recorded for GP. The shortest sealing times for medium and large vessels were observed with FT. The highest percentage failure rate for each vessel size occurred with GP. For 4-5 mm diameter vessels, the failure rate was 48% for GP, 41% for PK, and 22% for HS. For 6-7 mm diameter vessels, the failure rate was 92% for GP, 41% for PK, and 8% for HS. LM and FT had no recorded failures.
CONCLUSION: Among the new 5-mm laparoscopic electrosurgical and ultrasonic instruments available for testing, RX, LS, and FT produced the highest mean burst pressures. FT had the shortest mean seal times for medium and large vessels. Minimal or no seal failures occurred with HS, RX, LS, LM, and FT.

Entities:  

Mesh:

Year:  2008        PMID: 18483824     DOI: 10.1007/s00464-008-9932-x

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  16 in total

1.  Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery.

Authors:  T Kinoshita; E Kanehira; K Omura; K Kawakami; Y Watanabe
Journal:  Surg Endosc       Date:  1999-06       Impact factor: 4.584

2.  How safe is high-power ultrasonic dissection?

Authors:  Tarek A Emam; Alfred Cuschieri
Journal:  Ann Surg       Date:  2003-02       Impact factor: 12.969

3.  Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.

Authors:  Jaime Landman; Kurt Kerbl; Jamil Rehman; Cassio Andreoni; Peter A Humphrey; William Collyer; Ephrem Olweny; Chandru Sundaram; Ralph V Clayman
Journal:  J Urol       Date:  2003-02       Impact factor: 7.450

4.  Real-time thermography during energized vessel sealing and dissection.

Authors:  P A Campbell; A B Cresswell; T G Frank; A Cuschieri
Journal:  Surg Endosc       Date:  2003-07-21       Impact factor: 4.584

5.  Electrosurgery: history, principles, and current and future uses.

Authors:  Nader N Massarweh; Ned Cosgriff; Douglas P Slakey
Journal:  J Am Coll Surg       Date:  2006-03       Impact factor: 6.113

6.  Comparison of monopolar electrocoagulation, bipolar electrocoagulation, Ultracision, and Ligasure.

Authors:  Theodore Diamantis; Michael Kontos; Antonios Arvelakis; Spiridon Syroukis; Dimitris Koronarchis; Apostolos Papalois; Emmanuel Agapitos; Elias Bastounis; Andreas C Lazaris
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

Review 7.  Principles and initial experience of a new device for dissection and hemostasis.

Authors:  A S Gözen; D Teber; J J Rassweiler
Journal:  Minim Invasive Ther Allied Technol       Date:  2007       Impact factor: 2.442

8.  High-burst-strength, feedback-controlled bipolar vessel sealing.

Authors:  J S Kennedy; P L Stranahan; K D Taylor; J G Chandler
Journal:  Surg Endosc       Date:  1998-06       Impact factor: 4.584

9.  Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis.

Authors:  Eduardo Ma Targarona; Carmen Balague; Juan Marin; Rene Berindoague Neto; Carmen Martinez; Jordi Garriga; Manuel Trias
Journal:  Surg Innov       Date:  2005-12       Impact factor: 2.058

10.  Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study.

Authors:  Roberto Campagnacci; Angelo de Sanctis; Maddalena Baldarelli; Massimiliano Rimini; Giovanni Lezoche; Mario Guerrieri
Journal:  Surg Endosc       Date:  2007-02-08       Impact factor: 4.584

View more
  37 in total

1.  Synthetic polymer-tissue adhesion using an ultrasonic scalpel.

Authors:  Kenji Yamamoto; Tsuyoshi Kimura; Kwangwoo Nam; Seiichi Funamoto; Yukiko Ito; Kumiko Shiba; Ayako Katoh; Shigeru Shimizu; Kimio Kurita; Tetsuya Higami; Toru Masuzawa; Akio Kishida
Journal:  Surg Endosc       Date:  2010-10-07       Impact factor: 4.584

2.  Efficacy and safety of the novel electrosurgical vessel sealing and cutting instrument BiCision®.

Authors:  Ralf Rothmund; Bernhard Kraemer; Felix Neis; Sara Brucker; Markus Wallwiener; Ali Reda; Andrea Hausch; Marcus Scharpf; Mara Natascha Szyrach
Journal:  Surg Endosc       Date:  2012-06-08       Impact factor: 4.584

Review 3.  Surgical Efficacy Among Laparoscopic Ultrasonic Dissectors: Are We Advancing Safely? A Review of Literature.

Authors:  Rajesh Devassy; Sreelatha Gopalakrishnan; Rudy Leon De Wilde
Journal:  J Obstet Gynaecol India       Date:  2015-09-14

4.  Prospective analysis of the sealing ability of the ENSEAL® G2 Articulating Tissue Sealer and transector on human mesenteric vessels in colorectal surgery.

Authors:  B Balachandran; G Melich; T Mustafa; S J Marecik; L M Prasad; M Gonzalez; S Sulo; F Dabbous; J J Park
Journal:  Tech Coloproctol       Date:  2017-01-31       Impact factor: 3.781

5.  Perpendicular blood vessel seals are stronger than those made at an angle.

Authors:  Aaron C Voegele; Donna L Korvick; Mario Gutierrez; Jeffrey W Clymer; Joseph F Amaral
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2013-06-11       Impact factor: 1.878

6.  Collagen-elastin ratio predicts burst pressure of arterial seals created using a bipolar vessel sealing device in a porcine model.

Authors:  David Sindram; Kimberly Martin; Jarrod P Meadows; Ajita S Prabhu; Jessica J Heath; Iain H McKillop; David A Iannitti
Journal:  Surg Endosc       Date:  2011-03-15       Impact factor: 4.584

7.  A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy.

Authors:  Ralf Rothmund; Mara Szyrach; Ali Reda; Markus D Enderle; Alexander Neugebauer; Florin-Andrei Taran; Sara Brucker; Andrea Hausch; Christian Wallwiener; Bernhard Kraemer
Journal:  Surg Endosc       Date:  2013-05-14       Impact factor: 4.584

8.  A prospective trial evaluating the clinical performance of a novel surgical energy device in laparoscopic colon surgery.

Authors:  J W Milsom; K Trencheva; T Sonoda; G Nandakumar; P J Shukla; S Lee
Journal:  Surg Endosc       Date:  2014-08-27       Impact factor: 4.584

9.  A continuum thermomechanical model of in vivo electrosurgical heating of hydrated soft biological tissues.

Authors:  Wafaa Karaki; Carlos A Lopez; Diana-Andra Borca-Tasciuc; Suvranu De
Journal:  Int J Heat Mass Transf       Date:  2018-07-14       Impact factor: 5.584

10.  Surface-processing technology of a microgrooving and water-repellent coating improves the fusion potential of an ultrasonic energy device.

Authors:  Satoru Okada; Junichi Shimada; Kazuhiro Ito; Tatsuo Ishii; Koichiro Oshiumi
Journal:  Surg Endosc       Date:  2016-06-22       Impact factor: 4.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.