Literature DB >> 9474625

A comparison of Kodak Ektaspeed Plus film and the Siemens Sidexis digital imaging system for caries detection using receiver operating characteristic analysis.

D A Tyndall1, J B Ludlow, E Platin, M Nair.   

Abstract

OBJECTIVE: To evaluate the accuracy of proximal caries detection comparing enhanced and unenhanced Siemens Sidexis CCD-based digital images with Ektaspeed Plus films utilizing receiver operating characteristic analysis. STUDY
DESIGN: Sixty extracted teeth (24 posterior and 36 anterior) were imaged under identical standardized geometric and exposure conditions. Six observers, using a 5-point confidence scale, rated 120 proximal surfaces for the presence or absence of carious lesions by means of three image modalities: (1) observer enhanced and (2) unenhanced Sidexis displays, and (3) Ektaspeed Plus films. The ground truth was determined by microscopic analysis of ground sections. Receiver operating characteristic curves were generated with calculated areas (AZ) analyzed with analysis of variance for effect of reader, reading, and modality.
RESULTS: Analysis of variance demonstrated significant differences among readers, readings and modalities (mean square values of 0.012, 0.005, 0.004, F ratios of 13.604, 5.329, 5.100; p = values of 0.001, 0.043, and 0.030, respectively). Post-hoc paired comparisons of modalities using Tukey's statistic demonstrated that only film and enhanced Sidexis images were different from each other (p = 0.024). AZ scores were 0.7650, 0.7499, and 0.8008 respectively, for unenhanced Sidexis, enhanced Sidexis, and Ektaspeed Plus film.
CONCLUSION: Unenhanced digital Sidexis images were equivalent to film for the detection of proximal caries in this in vitro study. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the unenhanced digital and film images.

Entities:  

Mesh:

Year:  1998        PMID: 9474625     DOI: 10.1016/s1079-2104(98)90408-5

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  18 in total

1.  Ex vivo comparison of Galileos cone beam CT and intraoral radiographs in detecting occlusal caries.

Authors:  S Rathore; D Tyndall; Jt Wright; E Everett
Journal:  Dentomaxillofac Radiol       Date:  2011-12-19       Impact factor: 2.419

2.  Comparison of digital systems and conventional dental film for the detection of approximal enamel caries.

Authors:  A A Pontual; D P de Melo; S M de Almeida; F N Bóscolo; F Haiter Neto
Journal:  Dentomaxillofac Radiol       Date:  2010-10       Impact factor: 2.419

3.  Diagnostic accuracy of different imaging modalities in detection of proximal caries.

Authors:  B Senel; K Kamburoglu; O Uçok; S P Yüksel; T Ozen; H Avsever
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

4.  Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.

Authors:  Mehmet Ilgüy; Semanur Dinçer; Dilhan Ilgüy; Gündüz Bayirli
Journal:  J Digit Imaging       Date:  2008-10-24       Impact factor: 4.056

5.  The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.

Authors:  D D Brüllmann; B d'Hoedt
Journal:  Dentomaxillofac Radiol       Date:  2011-05       Impact factor: 2.419

6.  Influence of brightness and contrast adjustments on the diagnosis of proximal caries lesions.

Authors:  Eduarda Hl Nascimento; Hugo Gaêta-Araujo; Karla F Vasconcelos; Bernardo B Freire; Christiano Oliveira-Santos; Francisco Haiter-Neto; Deborah Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2018-06-15       Impact factor: 2.419

7.  Detection of non-cavitated approximal caries lesions in digital images from seven solid-state receptors with particular focus on task-specific enhancement filters. An ex vivo study in human teeth.

Authors:  Francisco Haiter-Neto; Andrea dos Anjos Pontual; Morten Frydenberg; Ann Wenzel
Journal:  Clin Oral Investig       Date:  2008-01-22       Impact factor: 3.573

8.  Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study.

Authors:  Rafael Scaf de Molon; Juliana Aparecida Najarro Dearo Morais-Camillo; Celso Eduardo Sakakura; Mauricio Goncalves Ferreira; Leonor Castro Monteiro Loffredo; Gulnara Scaf
Journal:  Imaging Sci Dent       Date:  2012-12-23

9.  Effect of computer assistance on observer performance of approximal caries diagnosis using intraoral digital radiography.

Authors:  Kazuyuki Araki; Yukiko Matsuda; Kenji Seki; Tomohiro Okano
Journal:  Clin Oral Investig       Date:  2009-06-26       Impact factor: 3.573

Review 10.  The missing link in image quality assessment in digital dental radiography.

Authors:  Kazutoshi Okamura; Kazunori Yoshiura
Journal:  Oral Radiol       Date:  2019-07-13       Impact factor: 1.852

View more