Literature DB >> 31302866

The missing link in image quality assessment in digital dental radiography.

Kazutoshi Okamura1, Kazunori Yoshiura2.   

Abstract

Digital radiography is gaining popularity among general dental practitioners. It includes digital intraoral radiography, digital panoramic radiography, digital cephalography, and cone-beam computed tomography. In this study, we focused on the methods to assess image quality of these techniques, except for digital cephalography, in the light of historical issues. We stressed on the importance of the development of a standardized phantom and quantitative analysis of diagnostic image quality using it, especially in the aspect of psychophysical properties of these digital systems. There is no missing link in the image quality assessment in digital intraoral radiography and cone-beam computed tomography in dental use. However, there are missing links between physical and diagnostic image qualities in panoramic radiography. The development of a semi-standardized phantom and the corresponding quantitative analysis method for image quality may be required in digital panoramic radiography. Quantitative image quality assessment using a standardized phantom will also be promising in the future artificial intelligence era.

Entities:  

Keywords:  Dental; Digital; Image quality; Patient dose; Radiography

Mesh:

Year:  2019        PMID: 31302866     DOI: 10.1007/s11282-019-00396-z

Source DB:  PubMed          Journal:  Oral Radiol        ISSN: 0911-6028            Impact factor:   1.852


  42 in total

1.  Quality of film-based and digital panoramic radiography.

Authors:  B Molander; H-G Gröndahl; A Ekestubbe
Journal:  Dentomaxillofac Radiol       Date:  2004-01       Impact factor: 2.419

2.  A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT) Part I. On subjective image quality.

Authors:  Xin Liang; Reinhilde Jacobs; Bassam Hassan; Limin Li; Ruben Pauwels; Livia Corpas; Paulo Couto Souza; Wendy Martens; Maryam Shahbazian; Arie Alonso; Ivo Lambrichts
Journal:  Eur J Radiol       Date:  2009-05-01       Impact factor: 3.528

Review 3.  Digital radiology in dental diagnosis: a critical view.

Authors:  H G Gröndahl
Journal:  Dentomaxillofac Radiol       Date:  1992-11       Impact factor: 2.419

Review 4.  Physical performance measures of radiographic imaging systems.

Authors:  A Workman; D S Brettle
Journal:  Dentomaxillofac Radiol       Date:  1997-05       Impact factor: 2.419

Review 5.  Radiation protection in dental radiology - Recent advances and future directions.

Authors:  V Tsapaki
Journal:  Phys Med       Date:  2017-08-05       Impact factor: 2.685

6.  A new method to evaluate image quality of CBCT images quantitatively without observers.

Authors:  Yohei Takeshita; Mayumi Shimizu; Kazutoshi Okamura; Shoko Yoshida; Warangkana Weerawanich; Kenji Tokumori; Gainer R Jasa; Kazunori Yoshiura
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

7.  Evaluation of receiver operating characteristic curve data in terms of information theory, with applications in radiography.

Authors:  C E Metz; D J Goodenough; K Rossmann
Journal:  Radiology       Date:  1973-11       Impact factor: 11.105

8.  Prediction of detectability of the mandibular canal by quantitative image quality evaluation using cone beam CT.

Authors:  Yohei Takeshita; Mayumi Shimizu; Gainer R Jasa; Warangkana Weerawanich; Kazutoshi Okamura; Shoko Yoshida; Kenji Tokumori; Junichi Asaumi; Kazunori Yoshiura
Journal:  Dentomaxillofac Radiol       Date:  2018-02-13       Impact factor: 2.419

Review 9.  Toward consensus on quantitative assessment of medical imaging systems.

Authors:  C E Metz; R F Wagner; K Doi; D G Brown; R M Nishikawa; K J Myers
Journal:  Med Phys       Date:  1995-07       Impact factor: 4.071

Review 10.  Image quality in CT: From physical measurements to model observers.

Authors:  F R Verdun; D Racine; J G Ott; M J Tapiovaara; P Toroi; F O Bochud; W J H Veldkamp; A Schegerer; R W Bouwman; I Hernandez Giron; N W Marshall; S Edyvean
Journal:  Phys Med       Date:  2015-10-12       Impact factor: 2.685

View more
  2 in total

1.  Clinical comparison of intraoral CMOS and PSP detectors in terms of time efficiency, patient comfort, and subjective image quality.

Authors:  Kıvanç Kamburoğlu; Erçin Samunahmetoğlu; Nejlan Eratam; Gül Sönmez; Sevilay Karahan
Journal:  Imaging Sci Dent       Date:  2022-02-11

2.  Multimodality system of x-ray and fluorescence based on Fourier single-pixel imaging for small animals.

Authors:  Zhuoyao Huang; Jie Zhang; Hui Gong; Xiaoquan Yang
Journal:  J Biomed Opt       Date:  2022-09       Impact factor: 3.758

  2 in total