Literature DB >> 18949518

Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.

Mehmet Ilgüy1, Semanur Dinçer, Dilhan Ilgüy, Gündüz Bayirli.   

Abstract

The aim of this study was to determine diagnostic performance of a storage phosphor plate system Digora Optime (Soredex, Helsinki, Finland) with two types of LCD monitor in the detection of artificial caries when compared to Ultraspeed (D), Ektaspeed Plus (E), and Insight (F) radiographic films. Seventy extracted human molars-with artificial caries-were radiographed under identical standardized conditions using (1) a storage phosphor plate system Digora (Soredex, Helsinki, Finland), (2) Insight, (3) Ektaspeed Plus, and (4) Ultraspeed (Carestream Health Inc, Rochester, NY). All digital images and radiographs were examined by three observers for the presence or absence of artificial caries using a five-point confidence scale. Digital images were evaluated both on a LCD computer monitor (Philips 170S, Holland) and medical monitor-3 megapixel monochrome display (Me355i2, Totoku, Tokyo)-with brightness and contrast enhancement. Observer responses were evaluated using ROC analysis and other measurements for diagnostic accuracy. Storage phosphor images with medical monitor demonstrated higher mean A (z) values (0.70 +/- 0.08) than digital images with computer monitor and conventional films. Storage phosphor images with medical monitor presented the highest score, 0.97, 0.90, 0.94, for each observer, respectively. Also, true positive observations (0.82) and positive likelihood ratios (2.71) were higher in enhanced storage phosphor images with medical monitor. Caries detection of mechanically created lesions by experienced radiologists is roughly comparable when examining D-speed film images and Digora images on both the computer and medical LCD monitors, and appears to be poorer on E- and F-speed film images.

Entities:  

Mesh:

Year:  2008        PMID: 18949518      PMCID: PMC3043700          DOI: 10.1007/s10278-008-9146-8

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  47 in total

1.  Sensitometric and clinical evaluation of a new F-speed dental X-ray film.

Authors:  K Syriopoulos; X L Velders; G C Sanderink; P F van Der Stelt
Journal:  Dentomaxillofac Radiol       Date:  2001-01       Impact factor: 2.419

2.  Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems.

Authors:  H Hintze; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2002-01       Impact factor: 2.419

3.  Urinary calculi on computed radiography: comparison of observer performance with hard-copy versus soft-copy images on different viewer systems.

Authors:  A Y Kim; K S Cho; K S Song; J H Kim; J G Kim; H K Ha
Journal:  AJR Am J Roentgenol       Date:  2001-08       Impact factor: 3.959

4.  Sensitometric comparison of speed group E and F dental radiographic films.

Authors:  J R Geist; J W Brand
Journal:  Dentomaxillofac Radiol       Date:  2001-05       Impact factor: 2.419

5.  Performance of a new F-speed film for caries detection.

Authors:  J B Ludlow; M Abreu; A Mol
Journal:  Dentomaxillofac Radiol       Date:  2001-03       Impact factor: 2.419

6.  An in-vitro evaluation of Kodak Insight and Ektaspeed Plus film with a CMOS detector for natural proximal caries: ROC analysis.

Authors:  M K Nair; U P Nair
Journal:  Caries Res       Date:  2001 Sep-Oct       Impact factor: 4.056

7.  Image processing and enhancement provided by commercial dental software programs.

Authors:  T M Lehmann; E Troeltsch; K Spitzer
Journal:  Dentomaxillofac Radiol       Date:  2002-07       Impact factor: 2.419

8.  Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries.

Authors:  Elaine Aparecida Félix de Araujo; Julio Cezar de Melo Castilho; Edmundo Medici Filho; Mari Eli Leonelli de Moraes
Journal:  Am J Dent       Date:  2005-08       Impact factor: 1.522

9.  Updated quality assurance self-assessment exercise in intraoral and panoramic radiography. American Academy of Oral and Maxillofacial Radiology, Radiology Practice Committee.

Authors:  A D Goren; R C Lundeen; S T Deahl; K Hashimoto; S F Kapa; J O Katz; J B Ludlow; E Platin; P F Van Der Stelt; L Wolfgang
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2000-03

10.  Perceived quality of radiographic images after rapid processing of D- and F-speed direct-exposure intraoral x-ray films.

Authors:  Duane I Bernstein; Stephen J Clark; James P Scheetz; Allan G Farman; Beth Rosenson
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2003-10
View more
  11 in total

1.  Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.

Authors:  Elif Sogur; B Güniz Baksı; Kaan Orhan; S Candan Paksoy; Salih Dogan; Yılmaz S Erdal; Ali Mert
Journal:  Clin Oral Investig       Date:  2010-09-14       Impact factor: 3.573

2.  Effect of display type, DICOM calibration and room illuminance in bitewing radiographs.

Authors:  Soili Kallio-Pulkkinen; Sisko Huumonen; Marianne Haapea; Esa Liukkonen; Annina Sipola; Osmo Tervonen; Miika T Nieminen
Journal:  Dentomaxillofac Radiol       Date:  2015-08-03       Impact factor: 2.419

3.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

4.  Effect of display monitor devices on intra-oral radiographic caries diagnosis.

Authors:  Kazuyuki Araki; Mamiko Fujikura; Tsukasa Sano
Journal:  Clin Oral Investig       Date:  2015-01-18       Impact factor: 3.573

5.  Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT.

Authors:  İsmail H Baltacıoĝlu; Hakan Eren; Yasemin Yavuz; Kıvanç Kamburoğlu
Journal:  Dentomaxillofac Radiol       Date:  2016-07-04       Impact factor: 2.419

6.  Comparison of intraoral radiography and cone-beam computed tomography for the detection of horizontal root fractures: an in vitro study.

Authors:  Hakan Avsever; Kaan Gunduz; Kaan Orhan; Ismail Uzun; Bilal Ozmen; Erol Egrioglu; Muhammed Midilli
Journal:  Clin Oral Investig       Date:  2013-02-09       Impact factor: 3.573

7.  Digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis.

Authors:  Maryam Tofangchiha; Mamak Adel; Mahin Bakhshi; Mahsa Esfehani; Pantea Nazeman; Mojgan Ghorbani Elizeyi; Amir Javadi
Journal:  Iran Endod J       Date:  2013-01-20

8.  Comparison of digital image displays performance in the detection of artificial internal root resorptions lesions.

Authors:  Matheus Nogueira da Hora; Lucas de Paula Lopes Rosado; Frederico Sampaio Neves; Ieda Crusoé-Rebello; Taruska Ventorini Vasconcelos
Journal:  Dentomaxillofac Radiol       Date:  2021-04-09       Impact factor: 3.525

9.  Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Liogi Iwaki Filho; Alfredo De Franco Queiroz; Lucas Bachegas Gomes Geron
Journal:  Contemp Clin Dent       Date:  2013-07

10.  Assessing the Accuracy of Caries Diagnosis in Bitewing Radiographs Using Different Reproduction Media.

Authors:  Sadaf Adibi; Anita Amrollahi; Ali Dehghani Nazhvani; Najmeh Movahhedian
Journal:  J Dent (Shiraz)       Date:  2018-09
View more