Literature DB >> 9420669

A method of simultaneous dual-radionuclide cardiac imaging with technetium 99m and thallium 201. I: Analysis of interradionuclide crossover and validation in phantoms.

H Weinstein1, M A King, C P Reinhardt, B A McSherry, J A Leppo.   

Abstract

BACKGROUND: Simultaneous dual-radionuclide technetium 99m/thallium 201 scintigraphy can potentially produce perfectly aligned stress and rest images in less time than conventional protocols. However, interradionuclide crossover limits diagnostic accuracy. Accordingly, we evaluated 99mTc and 201Tl crossover in line and heart phantoms. METHODS AND
RESULTS: 99mTc crossover in the 201Tl imaging window constituted as much as one half of the counts in the 99mTc window, varied significantly with attenuation, and was spatially incoherent. 201Tl crossover was relatively small, less variable, and spatially similar to the primary image. Based on these findings, the following simultaneous dual-radionuclide 99mTc/201Tl method was developed, and validated in line and heart phantoms. The 99mTc source is imaged first into dual 201Tl/99mTc windows, followed by 201Tl administration and dual-radionuclide imaging. The single-radionuclide 99mTc image in the 201Tl window is count-normalized for acquisition time and then subtracted from the dual-radionuclide 201Tl image to specifically correct for 99mTc crossover. Image quality of the corrected dual-radionuclide 201Tl images approached their single-radionuclide counterparts. Correction for 201Tl crossover was relatively unimportant.
CONCLUSION: Simultaneous dual-radionuclide 99mTc/201Tl myocardial scintigraphy is feasible with 99mTc crossover correction specific to each acquisition. The proposed dual-radionuclide 99mTc/201Tl method and the principles on which it is based can be applied to a broad range of dual-radionuclide pairs.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 9420669     DOI: 10.1007/bf02940010

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  24 in total

1.  Dual-isotope brain SPECT imaging with technetium-99m and iodine-123: validation by phantom studies.

Authors:  M D Devous; J L Lowe; J K Payne
Journal:  J Nucl Med       Date:  1992-11       Impact factor: 10.057

2.  Dual-isotope brain SPECT imaging with technetium-99m and iodine-123: clinical validation using xenon-133 SPECT.

Authors:  M D Devous; J K Payne; J L Lowe
Journal:  J Nucl Med       Date:  1992-11       Impact factor: 10.057

3.  Assessment and comparison of three scatter correction techniques in single photon emission computed tomography.

Authors:  M C Gilardi; V Bettinardi; A Todd-Pokropek; L Milanesi; F Fazio
Journal:  J Nucl Med       Date:  1988-12       Impact factor: 10.057

4.  Improved SPECT quantification using compensation for scattered photons.

Authors:  R J Jaszczak; K L Greer; C E Floyd; C C Harris; R E Coleman
Journal:  J Nucl Med       Date:  1984-08       Impact factor: 10.057

5.  Nitroprusside.

Authors:  J N Cohn; L P Burke
Journal:  Ann Intern Med       Date:  1979-11       Impact factor: 25.391

6.  Dual isotope thallium and indium antimyosin SPECT imaging to identify acute infarct patients at further ischemic risk.

Authors:  L L Johnson; D W Seldin; A M Keller; R M Wall; K Bhatia; C O Bingham; M E Tresgallo
Journal:  Circulation       Date:  1990-01       Impact factor: 29.690

7.  Dual isotope scintigraphy in stroke patients.

Authors:  C Kessler; R Reuther; B Kimmig; T Pietzsch
Journal:  Neuroradiology       Date:  1984       Impact factor: 2.804

8.  Simultaneous measurement of left ventricular function and myocardial perfusion during a single exercise test: dual isotope imaging with gold-195 m and thallium-201.

Authors:  A Lahiri; G D Zanelli; M J O'Hara; M J Bowles; R I Jones; A P Cave; E B Raftery
Journal:  Eur Heart J       Date:  1986-06       Impact factor: 29.983

9.  Radiation necrosis vs high-grade recurrent glioma: differentiation by using dual-isotope SPECT with 201TI and 99mTc-HMPAO.

Authors:  R B Schwartz; P A Carvalho; E Alexander; J S Loeffler; R Folkerth; B L Holman
Journal:  AJNR Am J Neuroradiol       Date:  1991 Nov-Dec       Impact factor: 3.825

10.  Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: a comparative dual-isotope study.

Authors:  R Zimmermann; B Rauch; M Kapp; B Bubeck; F J Neumann; F Seitz; P Stokstad; G Mall; H Tillmanns; W Kübler
Journal:  Eur J Nucl Med       Date:  1992
View more
  4 in total

1.  Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defects.

Authors:  H M Siebelink; D Natale; A J Sinusas; F J Wackers
Journal:  J Nucl Cardiol       Date:  1996 Nov-Dec       Impact factor: 5.952

2.  Simultaneous dual-radionuclide imaging: are the images trustworthy?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1996-10

3.  Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.

Authors:  P Hannequin; P Weinmann; J Mas; S Vinot
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952

4.  Iterative deconvolution of simultaneous 99mTc and 201Tl projection data measured on a CdZnTe-based cardiac SPECT scanner.

Authors:  Krzysztof Kacperski; Kjell Erlandsson; Simona Ben-Haim; Brian F Hutton
Journal:  Phys Med Biol       Date:  2011-02-11       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.