Literature DB >> 3264020

Assessment and comparison of three scatter correction techniques in single photon emission computed tomography.

M C Gilardi1, V Bettinardi, A Todd-Pokropek, L Milanesi, F Fazio.   

Abstract

The detection of scattered radiation is recognized as one of the major sources of error in single photon emission computed tomography (SPECT). In this work three scatter correction techniques have been assessed and compared. Scatter coefficients and parameters characteristic of each technique have been calculated through Monte Carlo simulations and experimentally measured for various source geometries. Their dependence on the source/matter distribution and their spatial non-stationarity have been described. Each of the three scatter correction methods has then been tested on several SPECT phantom studies. The three methods provided comparable results. Following scatter compensation, both image quality and quantitative accuracy improved. In particular a slight improvement in spatial resolution and a statistically significant increase in cold lesion contrast, hot lesion recovery coefficient, and signal/noise ratio have been demonstrated with all methods.

Mesh:

Year:  1988        PMID: 3264020

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  6 in total

1.  Correction of scattered photons in Tc-99m imaging by means of a photopeak dual-energy window acquisition.

Authors:  A Kojima; A Tsuji; Y Takaki; S Tomiguchi; M Hara; M Matsumoto; M Takahashi
Journal:  Ann Nucl Med       Date:  1992-08       Impact factor: 2.668

2.  Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method.

Authors:  H Almquist; J Palmer; M Ljungberg; P Wollmer; S E Strand; B Jonson
Journal:  Eur J Nucl Med       Date:  1990

3.  A method of simultaneous dual-radionuclide cardiac imaging with technetium 99m and thallium 201. I: Analysis of interradionuclide crossover and validation in phantoms.

Authors:  H Weinstein; M A King; C P Reinhardt; B A McSherry; J A Leppo
Journal:  J Nucl Cardiol       Date:  1994 Jan-Feb       Impact factor: 5.952

4.  Analysis of the reconstructibility and noise properties of scattered photons in 99mTc SPECT.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

Review 5.  Scatter correction in scintigraphy: the state of the art.

Authors:  I Buvat; H Benali; A Todd-Pokropek; R Di Paola
Journal:  Eur J Nucl Med       Date:  1994-07

6.  Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: a multicenter trial.

Authors:  J M Links; L C Becker; P Rigo; R Taillefer; L Hanelin; F Anstett; D Burckhardt; L Mixon
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

  6 in total