Literature DB >> 19025894

Single-shot multiecho parallel echo-planar imaging (EPI) for diffusion tensor imaging (DTI) with improved signal-to-noise ratio (SNR) and reduced distortion.

Roger Nana1, Tiejun Zhao, Xiaoping Hu.   

Abstract

In this work, a multiecho parallel echo-planar imaging (EPI) acquisition strategy is introduced as a way to improve the acquisition efficiency in parallel diffusion tensor imaging (DTI). With the use of an appropriate echo combination strategy, the sequence can provide signal-to-noise ratio (SNR) enhancement while maintaining the advantages of parallel EPI. Simulations and in vivo experiments demonstrate that a weighted summation of multiecho images provides a significant gain in SNR over the first echo image. It is experimentally demonstrated that this SNR gain can be utilized to reduce the number of measurements often required to ensure adequate SNR for accurate DTI measures. Furthermore, the multiple echoes can be used to derive a T(2) map, providing additional information that might be useful in some applications. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 19025894      PMCID: PMC2737507          DOI: 10.1002/mrm.21770

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  SENSE-DTI at 3 T.

Authors:  T Jaermann; G Crelier; K P Pruessmann; X Golay; T Netsch; A M C van Muiswinkel; S Mori; P C M van Zijl; A Valavanis; S Kollias; P Boesiger
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

4.  Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo.

Authors:  T G Reese; O Heid; R M Weisskoff; V J Wedeen
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

5.  SNR-optimality of sum-of-squares reconstruction for phased-array magnetic resonance imaging.

Authors:  Erik G Larsson; Deniz Erdogmus; Rui Yan; Jose C Principe; Jeffrey R Fitzsimmons
Journal:  J Magn Reson       Date:  2003-07       Impact factor: 2.229

6.  Diffusion anisotropy in subcortical white matter and cortical gray matter: changes with aging and the role of CSF-suppression.

Authors:  Yusuf A Bhagat; Christian Beaulieu
Journal:  J Magn Reson Imaging       Date:  2004-08       Impact factor: 4.813

7.  Improved time efficiency and accuracy in diffusion tensor microimaging with multiple-echo acquisition.

Authors:  Vikas Gulani; Thomas Weber; Thomas Neuberger; Andrew G Webb
Journal:  J Magn Reson       Date:  2005-09-23       Impact factor: 2.229

8.  64-channel array coil for single echo acquisition magnetic resonance imaging.

Authors:  Mary Preston McDougall; Steven M Wright
Journal:  Magn Reson Med       Date:  2005-08       Impact factor: 4.668

9.  Impact of an improved combination of signals from array coils in diffusion tensor imaging.

Authors:  Guillaume Gilbert; Dany Simard; Gilles Beaudoin
Journal:  IEEE Trans Med Imaging       Date:  2007-11       Impact factor: 10.048

Review 10.  Applications of diffusion-weighted and diffusion tensor MRI to white matter diseases - a review.

Authors:  Mark A Horsfield; Derek K Jones
Journal:  NMR Biomed       Date:  2002 Nov-Dec       Impact factor: 4.044

View more
  7 in total

1.  Prediction of hemorrhagic transformation after experimental ischemic stroke using MRI-based algorithms.

Authors:  Mark Jrj Bouts; Ivo Acw Tiebosch; Umesh S Rudrapatna; Annette van der Toorn; Ona Wu; Rick M Dijkhuizen
Journal:  J Cereb Blood Flow Metab       Date:  2016-01-01       Impact factor: 6.200

2.  Evaluation of radiation necrosis and malignant glioma in rat models using diffusion tensor MR imaging.

Authors:  Silun Wang; Yifei Chen; Bachchu Lal; Eric Ford; Erik Tryggestad; Michael Armour; Kun Yan; John Laterra; Jinyuan Zhou
Journal:  J Neurooncol       Date:  2011-09-27       Impact factor: 4.130

Review 3.  Role of Diffusion Tensor MR Imaging in Degenerative Cervical Spine Disease: a Review of the Literature.

Authors:  A Banaszek; J Bladowska; P Podgórski; M J Sąsiadek
Journal:  Clin Neuroradiol       Date:  2015-09-30       Impact factor: 3.649

4.  Detection of middle ear cholesteatoma by diffusion-weighted MR imaging: multishot echo-planar imaging compared with single-shot echo-planar imaging.

Authors:  K Yamashita; T Yoshiura; A Hiwatashi; H Kamano; T Dashjamts; S Shibata; A Tamae; H Honda
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-21       Impact factor: 3.825

5.  Phase-aligned multiple spin-echo averaging: a simple way to improve signal-to-noise ratio of in vivo mouse spinal cord diffusion tensor image.

Authors:  Tsang-Wei Tu; Matthew D Budde; Mingqiang Xie; Ying-Jr Chen; Qing Wang; James D Quirk; Sheng-Kwei Song
Journal:  Magn Reson Imaging       Date:  2014-08-01       Impact factor: 2.546

6.  Widespread effects of dMRI data quality on diffusion measures in children.

Authors:  Nabin Koirala; Daniel Kleinman; Meaghan V Perdue; Xing Su; Martina Villa; Elena L Grigorenko; Nicole Landi
Journal:  Hum Brain Mapp       Date:  2021-11-19       Impact factor: 5.038

7.  A hitchhiker's guide to diffusion tensor imaging.

Authors:  José M Soares; Paulo Marques; Victor Alves; Nuno Sousa
Journal:  Front Neurosci       Date:  2013-03-12       Impact factor: 4.677

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.